Administrator Guide
Table Of Contents
- Contents
- Figures
- Tables
- About This Document
- Understanding Fibre Channel Services
- Performing Basic Configuration Tasks
- Performing Advanced Configuration Tasks
- Routing Traffic
- Managing User Accounts
- Configuring Protocols
- Configuring Security Policies
- In this chapter
- ACL policies overview
- ACL policy management
- FCS policies
- DCC policies
- SCC policies
- Authentication policy for fabric elements
- IP Filter policy
- Creating an IP Filter policy
- Cloning an IP Filter policy
- Displaying an IP Filter policy
- Saving an IP Filter policy
- Activating an IP Filter policy
- Deleting an IP Filter policy
- IP Filter policy rules
- IP Filter policy enforcement
- Adding a rule to an IP Filter policy
- Deleting a rule to an IP Filter policy
- Aborting an IP Filter transaction
- IP Filter policy distribution
- Policy database distribution
- Management interface security
- Maintaining the Switch Configuration File
- Installing and Maintaining Firmware
- In this chapter
- Firmware download process overview
- Preparing for a firmware download
- Firmware download on switches
- Firmware download on an enterprise-class platform
- Firmware download from a USB device
- FIPS Support
- Test and restore firmware on switches
- Test and restore firmware on enterprise-class platforms
- Validating a firmware download
- Managing Virtual Fabrics
- In this chapter
- Virtual Fabrics overview
- Logical switch overview
- Logical fabric overview
- Management model for logical switches
- Account management and Virtual Fabrics
- Supported platforms for Virtual Fabrics
- Limitations and restrictions of Virtual Fabrics
- Enabling Virtual Fabrics mode
- Disabling Virtual Fabrics mode
- Configuring logical switches to use basic configuration values
- Creating a logical switch or base switch
- Executing a command in a different logical fabric context
- Deleting a logical switch
- Adding and removing ports on a logical switch
- Displaying logical switch configuration
- Changing the fabric ID of a logical switch
- Changing a logical switch to a base switch
- Setting up IP addresses for a Virtual Fabric
- Removing an IP address for a Virtual Fabric
- Configuring a logical switch to use XISLs
- Changing the context to a different logical fabric
- Creating a logical fabric using XISLs
- Administering Advanced Zoning
- In this chapter
- Special zones
- Zoning overview
- Broadcast zones
- Zone aliases
- Zone creation and maintenance
- Default zoning mode
- Zoning database size
- Zoning configurations
- Creating a zoning configuration
- Adding zones (members) to a zoning configuration
- Removing zones (members) from a zone configuration
- Enabling a zone configuration
- Disabling a zone configuration
- Deleting a zone configuration
- Clearing changes to a configuration
- Viewing all zone configuration information
- Viewing selected zone configuration information
- Viewing the configuration in the effective zone database
- Clearing all zone configurations
- Zone object maintenance
- Zoning configuration management
- Security and zoning
- Zone merging scenarios
- Traffic Isolation Zoning
- In this chapter
- Traffic Isolation Zoning overview
- Enhanced TI zones
- Traffic Isolation Zoning over FC routers
- General rules for TI zones
- Supported configurations for Traffic Isolation Zoning
- Limitations and restrictions of Traffic Isolation Zoning
- Admin Domain considerations for Traffic Isolation Zoning
- Virtual Fabric considerations for Traffic Isolation Zoning
- Traffic Isolation Zoning over FC routers with Virtual Fabrics
- Creating a TI zone
- Modifying TI zones
- Changing the state of a TI zone
- Deleting a TI zone
- Displaying TI zones
- Setting up TI over FCR (sample procedure)
- Administering NPIV
- Interoperability for Merged SANs
- In this chapter
- Interoperability overview
- Connectivity solutions
- Domain ID offset modes
- McDATA Fabric mode configuration restrictions
- McDATA Open Fabric mode configuration restrictions
- Interoperability support for logical switches
- Switch configurations for interoperability
- Zone management in interoperable fabrics
- Frame Redirection in interoperable fabrics
- Traffic Isolation zones in interoperable fabrics
- Brocade SANtegrity implementation in mixed fabric SANS
- E_Port authentication between Fabric OS and M-EOS switches
- FCR SANtegrity
- FICON implementation in a mixed fabric
- Fabric OS version change restrictions in an interoperable environment
- Coordinated Hot Code Load
- McDATA-aware features
- McDATA-unaware features
- Supported hardware in an interoperable environment
- Supported features in an interoperable environment
- Unsupported features in an interoperable environment
- Managing Administrative Domains
- In this chapter
- Administrative Domains overview
- Admin Domain management for physical fabric administrators
- Setting the default zoning mode for Admin Domains
- Creating an Admin Domain
- User assignments to Admin Domains
- Removing an Admin Domain from a user account
- Activating an Admin Domain
- Deactivating an Admin Domain
- Adding members to an existing Admin Domain
- Removing members from an Admin Domain
- Renaming an Admin Domain
- Deleting an Admin Domain
- Deleting all user-defined Admin Domains
- Deleting all user-defined Admin Domains non-disruptively
- Validating an Admin Domain member list
- SAN management with Admin Domains
- CLI commands in an AD context
- Executing a command in a different AD context
- Displaying an Admin Domain configuration
- Switching to a different Admin Domain context
- Admin Domain interactions with other Fabric OS features
- Admin Domains, zones, and zone databases
- Admin Domains and LSAN zones
- Configuration upload and download in an AD context
- Administering Licensing
- Monitoring Fabric Performance
- In this chapter
- Advanced Performance Monitoring overview
- End-to-end performance monitoring
- Frame monitoring
- ISL performance monitoring
- Top Talker monitors
- Adding a Top Talker monitor on an F_Port
- Adding Top Talker monitors on all switches in the fabric (fabric mode)
- Displaying the top n bandwidth-using flows on an F_Port
- Displaying top talking flows for a given domain ID (fabric mode)
- Deleting a Top Talker monitor on an F_Port
- Deleting the fabric mode Top Talker monitors
- Limitations of Top Talker monitors
- Trunk monitoring
- Displaying end-to-end and ISL monitor counters
- Clearing end-to-end and ISL monitor counters
- Saving and restoring monitor configurations
- Performance data collection
- Optimizing Fabric Behavior
- In this chapter
- Adaptive Networking overview
- Ingress Rate Limiting
- QoS: SID/DID traffic prioritization
- QoS zones
- QoS on E_Ports
- QoS over FC routers
- Virtual Fabric considerations for traffic prioritization
- High availability considerations for traffic prioritization
- Supported configurations for traffic prioritization
- Upgrade considerations for traffic prioritization
- Limitations and restrictions for traffic prioritization
- Setting traffic prioritization
- Setting traffic prioritization over FC routers
- Disabling QoS
- Bottleneck detection
- Supported configurations for bottleneck detection
- How bottlenecks are reported
- Limitations of bottleneck detection
- High availability considerations for bottleneck detection
- Upgrade and downgrade considerations for bottleneck detection
- Trunking considerations for bottleneck detection
- Virtual Fabrics considerations for bottleneck detection
- Access Gateway considerations for bottleneck detection
- Enabling bottleneck detection on a switch
- Excluding a port from bottleneck detection
- Displaying bottleneck detection configuration details
- Changing bottleneck alert parameters
- Displaying bottleneck statistics
- Disabling bottleneck detection on a switch
- Managing Trunking Connections
- Managing Long Distance Fabrics
- In this chapter
- Long distance fabrics overview
- Extended Fabrics device limitations
- Long distance link modes
- Configuring an extended ISL
- Buffer credit management
- Buffer-to-Buffer flow control
- Optimal buffer credit allocation
- Fibre Channel gigabit values reference definition
- Allocating buffer credits based on full-size frames
- Allocating buffer credits based on average-size frames
- Allocating buffer credits for F_Ports
- Displaying the remaining buffers in a port group
- Buffer credits for each switch model
- Maximum configurable distances for Extended Fabrics
- Buffer credit recovery
- Using the FC-FC Routing Service
- In this chapter
- FC-FC routing service overview
- Integrated Routing
- Fibre Channel routing concepts
- Setting up the FC-FC routing service
- Backbone fabric IDs
- FCIP tunnel configuration
- Inter-fabric link configuration
- FC Router port cost configuration
- EX_Port frame trunking configuration
- LSAN zone configuration
- Use of Admin Domains with LSAN zones and FCR
- Zone definition and naming
- LSAN zones and fabric-to-fabric communications
- Controlling device communication with the LSAN
- Setting the maximum LSAN count
- Configuring backbone fabrics for interconnectivity
- HA and downgrade considerations for LSAN zones
- LSAN zone policies using LSAN tagging
- LSAN zone binding
- Proxy PID configuration
- Fabric parameter considerations
- Inter-fabric broadcast frames
- Resource monitoring
- FC-FC Routing and Virtual Fabrics
- Upgrade and downgrade considerations for FC-FC routing
- Displaying the range of output ports connected to xlate domains
- M-EOS Migration Path to Fabric OS
- Inband Management
- Port Indexing
- FIPS Support
- Hexadecimal
- Index
Fabric OS Administrator’s Guide 397
53-1001763-02
Trunk monitoring
17
Limitations of Top Talker monitors
Be aware of the following when using Top Talker monitors:
• Top Talker monitors cannot detect transient surges in traffic through a given flow.
• You cannot install a Top Talker monitor on a mirrored port.
• Top Talker can monitor only 10,000 flows at a time.
• Top Talker is not supported on VE_Ports, EX_Ports, and VEX_Ports.
• The maximum number of F_Port Top Talker monitors on an ASIC is 16. If Virtual Fabrics is
enabled, the maximum number of F_Port Top Talker monitors on an ASIC is 8.
Trunk monitoring
To monitor E_Port (ISL) and F_Port trunks, you can set monitors only on the master port of the
trunk. If the master changes, the monitor automatically moves to the new master port.
If a monitor is installed on a port that later becomes a slave port when a trunk comes up, the
monitor automatically moves to the master port of the trunk.
Note the following:
• End-to-end monitors are not supported for ISLs.
• For F_Port trunks, end-to-end masks are allowed only on the F_Port trunk master. Unlike the
monitors, if the master changes, the mask does not automatically move to the new master
port.
• Brocade 300 platforms support eight frame monitors for trunks.
• The Brocade 4100, 4900, 5000, 5100, 5300, 5410, 5424, 5450, 5480, 7500, 7500E, 7600,
7800, 8000, VA-40FC48000, Brocade Encryption Switch, Brocade DCX, and DCX-4S platforms
support 12 frame monitors for trunks.
• For the Brocade 8000, trunk monitoring is supported only on the FC ports and not on the CEE
ports.
Displaying end-to-end and ISL monitor counters
You can use this procedure display the end-to-end or ISL monitors on a specified port. For
end-to-end counters, you can display either the cumulative count of the traffic detected by the
monitors or a snapshot of the traffic at specified intervals.
1. Connect to the switch and log in as admin.
2. Enter the perfmonitorshow command.
perfmonitorshow --class monitor_class [slotnumber/]portnumber [interval]
Example of displaying an end-to-end monitor on a port at 10-second intervals
switch:admin> perfMonitorShow --class EE 4/5 10
Showing EE monitors 4/5 10: Tx/Rx are # of bytes
01234
--------- --------- --------- --------- ---------
Tx Rx Tx Rx Tx Rx Tx Rx Tx Rx
========= ========= ========= ========= =========