Users Guide
Dell 10Gb Ethernet Pass Through II Rev 1.00
17
11 B 10G 10G SFP SX
#
# show port link 7
Port Group Connect Downlink Uplink
--------------------------------------------------------
7 A down down SFP+ SR
#
3.7.2 show port module
Synopsis:
show port module port_number
Description:
Show the transceiver module information for the specified uplink port.
Example:
# show port module 1
Status......................................... OK
Gigabit Ethernet Compliance Codes.............. 10GBASE-SR
Vendor Name.................................... FINISAR CORP.
Vendor Part Number............................. FTLX8571D3BCL-ME
Vendor Serial Number........................... UDD01@A
Vendor Revision Number......................... A
#
3.8 Debug Commands
3.8.1 cr_read (ADMIN)
Synopsis:
cr_read device_number 0xaddress
Description:
Read an internal PhyX device register. This command accepts the following parameters:
>device_number – the device from which to read a register (1..3)
>address – the register memory location from which to read (32-bit address)
Example:
& cr_read 2 0xf0014
0x000f0014:0x00a217d4