Computer Hardware User Manual
Table Of Contents
- Contents
- About Your System
- Using The System Setup And Boot Manager
- Installing Blade Components
- Recommended Tools
- Removing And Installing A Blade
- Opening And Closing The Blade
- Inside The Blade
- Cooling Shroud
- System Memory
- I/O Module Mezzanine Cards
- Management Riser Card
- SD vFlash Card
- Network Daughter Card/LOM Riser Card
- Processors
- Hard Drives/SSDs
- Hard-Drive/SSD Backplane
- System Board
- NVRAM Backup Battery
- Storage Controller Card
- Troubleshooting Your System
- Using System Diagnostics
- Jumpers And Connectors
- Technical Specifications
- System Messages
- Getting Help

Error Code Message Information
PCI3010
Message A non-fatal IO error detected on a component at bus <
bus
>device<
device
>function <
func
>.
Details System performance may be degraded.
Action Cycle input power, update component drivers, remove and reinstall the device at the next
service window.
PCI3012
Message The QuickPath Interconnect (QPI) width degraded.
Details System performance may be degraded. The bus is not operating at maximum speed or
width.
Action Reset the system, if the problem persists reinstall processors.
PCI3014
Message A non-fatal PCIe error detected on a component at slot <
number
>.
Details System performance may be degraded.
Action Cycle input power, update component drivers, remove and reinstall the device at the next
scheduled service time.
PDR0001
Message Fault detected on drive <
number
>.
LCD Message Fault detected on drive <
number
>. Check drive.
Details The controller detected a failure on the disk and has taken the disk offline.
Action Remove and re-seat the failed disk. If the issue persists, see Getting Help.
PDR0002
Message A predictive failure detected on drive <
number
>.
Details The controller received a SMART error from the drive. The drive is operational but needs
replacement.
Action The drive will need replacement at the next service window.
PDR0016
Message Drive <
number
> is removed.
LCD Message Drive <
number
> is removed. Check drive.
Details The controller detected a drive removal.
Action If unintended, verify drive installation. Remove and re-seat the indicated disk. If the
issue persists, see Getting Help.
PDR1001
Message Fault detected on drive <
number
> in disk drive bay <
bay
>.
LCD Message Fault detected on drive <
number
> in disk drive bay <
bay
>. Check drive.
Details The controller detected a failure on the disk and has taken the disk offline.
Action Re-seat the failed drive. If the issue persists, see Getting Help.
PDR1002
Message A predictive failure detected on drive <
number
> in disk drive bay<
bay
>.
101