- Getting Help
Error Code Message Information
CPU0008
Message CPU <
number
> is disabled.
Details System is unable to boot or may run in a degraded state.
Action If unexpected, check presence, and system setup (BIOS) configuration.
CPU0010
Message CPU <
number
> is throttled.
Details The CPU is throttled due to thermal or power conditions.
Action Review system logs for power or thermal exceptions.
CPU0023
Message CPU <
number
> is absent.
LCD Message CPU <
number
> is absent. Check CPU.
Action Verify processor installation. If present, re-seat the processor.
CPU0100
Message CPU <
number
> temperature is less than the lower warning threshold.
Details System performance may be degraded.
Action Check system operating environment.
CPU0101
Message CPU <
number
> temperature is less than the lower critical threshold.
LCD Message CPU <
number
> temperature is outside of range.
Details System performance may be degraded.
Action Check system operating environment, fans, and heat-sinks.
CPU0102
Message CPU <
number
> temperature is greater than the upper warning threshold.
Details System performance may be degraded.
Action Check system operating environment, fans, and heat-sinks.
CPU0103
Message CPU <
number
> temperature is greater than the upper critical threshold.
LCD Message CPU <
number
> temperature is outside of range. Check fans.
Details System performance may be degraded.
Action Check system operating environment, fans, and heat-sinks.
CPU0104
Message CPU <
number
> temperature is outside of range.
LCD Message CPU <
number
> temperature is outside of range. Check fans.
Details System performance may be degraded.
Action Check system operating environment, fans, and heat-sinks.
CPU0200
Message CPU <
number
> <
name
> voltage is less than the lower warning threshold.
83