Error Code Message Information
Action Re-seat the memory modules. If the issue persists, see Getting Help.
MEM0004
Message Memory device at location <
location
> is disabled.
Details The memory may not be seated correctly, misconfigured, or has failed. Memory size is
reduced.
Action Re-seat the memory modules. If the issue persists, see Getting Help.
MEM0005
Message Persistent correctable memory error limit reached for a memory device at location(s)
<
location
>.
LCD Message Persistent correctable memory error limit reached for <
location
>. Re-seat memory.
Details The memory is operational. This an early indicator of a possible future uncorrectable
error.
Action Re-seat the memory modules. If the issue persists, see Getting Help.
MEM0007
Message Unsupported memory configuration; check memory device at location <
location
>.
LCD Message Unsupported memory configuration. Check memory <
location
>.
Details The memory may not be seated correctly, misconfigured, or has failed. Memory size is
reduced.
Action Check the memory configuration. Re-seat the memory modules. If the issue persists,
see Getting Help.
MEM0009
Message Memory device at location <
location
> is throttled.
Details System performance is degraded.
Action If unexpected, review system logs for power or thermal exceptions.
MEM0010
Message Memory device at location <
location
> is over heating.
LCD Message Memory device <
location
> is over heating. Check fans.
Details System performance is degraded.
Action If unexpected, review system logs for power or thermal exceptions.
MEM0022
Message Memory device at location <
location
> is absent.
Details The memory may not be seated correctly, misconfigured, or has failed. Memory size is
reduced.
Action Re-seat the memory modules. If the issue persists, see Getting Help.
MEM0701
Message Correctable memory error rate exceeded for <
location
>.
93