Computer Hardware User Manual
Table Of Contents
- Contents
- About Your System
- Using The System Setup And Boot Manager
- Installing Blade Components
- Recommended Tools
- Removing And Installing A Blade
- Opening And Closing The Blade
- Inside The Blade
- Cooling Shroud
- System Memory
- I/O Module Mezzanine Cards
- Management Riser Card
- SD vFlash Card
- Network Daughter Card/LOM Riser Card
- Processors
- Hard Drives/SSDs
- Hard-Drive/SSD Backplane
- System Board
- NVRAM Backup Battery
- Storage Controller Card
- Troubleshooting Your System
- Using System Diagnostics
- Jumpers And Connectors
- Technical Specifications
- System Messages
- Getting Help

Error Code Message Information
Details The memory may not be operational. This an early indicator of a possible future
uncorrectable error.
Action Re-seat the memory modules. If the issue persists, see Getting Help.
MEM0702
Message Correctable memory error rate exceeded for <
location
>.
LCD Message Correctable memory error rate exceeded for <
location
>. Re-seat memory.
Details The memory may not be operational. This an early indicator of a possible future
uncorrectable error.
Action Re-seat the memory modules. If the issue persists, see Getting Help.
MEM1001
Message Memory device at location <
location
> failed to transition to a running state.
LCD Message Memory device <
location
> failed to transition to a running state. Re-seat memory
Details The memory may not be operational. This an early indicator of a possible future
uncorrectable error.
Action Re-seat the memory modules. If the issue persists, see Getting Help.
MEM1003
Message Memory device at location <
location
> failed to transition to in test.
Details The memory may not be operational. This an early indicator of a possible future
uncorrectable error.
Action Re-seat the memory modules. If the issue persists, see Getting Help.
MEM1012
Message Memory device at location <
location
> is in a degraded state.
Details The memory may not be operational. This an early indicator of a possible future
uncorrectable error.
Action Re-seat the memory modules. If the issue persists, see Getting Help.
MEM1016
Message Memory device at location <
location
> is not installed correctly.
LCD Message Memory <
location
> is not installed correctly. Reinstall.
Details The memory may not be seated correctly, misconfigured, or has failed. Memory size is
reduced.
Action Check the memory configuration. Re-seat the memory modules. If the issue persists,
see Getting Help.
MEM1205
Message Memory mirror redundancy is lost. Check memory device at location(s) <
location
>.
LCD Message Memory mirror lost on <
location
>. Power cycle system.
Details The memory may not be seated correctly, misconfigured, or has failed.
94