Owners Manual

2. Restart the system
3. Enter System Setup
4. Set the drive as first in the boot sequence
The USB device is displayed in the Boot Order Setup screen only if it is attached to the system before you run the System
Setup. You can also select the boot device by pressing F11 during system start-up and selecting a boot device for the current
boot sequence.
Hard drive or SSD indicator patterns
The hard drive or SSD (Solid-State Drives) indicators display different patterns as drive events occur in the system.
NOTE: The server module must have a hard drive or SSD or a hard drive blank installed in each drive bay.
Figure 5. Hard drive or SSD indicators
1. drive activity indicator (green)
2. drive status indicator (green and amber)
NOTE:
If the drive is in Advanced Host Controller Interface (AHCI) mode, the status LED (on the right side) does not
function and remains off.
Table 5. Drive status indicator codes
Drive-status indicator pattern Condition
Flashes green twice per second Identifying drive or preparing for removal.
Off Drive ready for insertion or removal.
NOTE: The drive status indicator remains off until all hard
drives are initialized after the system is turned on. Drives are
not ready for insertion or removal during this time.
Flashes green, amber, and turns off Predicted drive failure
Flashes amber four times per second Drive failed
Steady green Drive online
Flashes green for three seconds, amber for three
seconds, and turns off after six seconds
Rebuild aborted