Users Guide

Table Of Contents
Selecting physical disks
Use the Select Physical Disks screen to select the physical disks to be used for the virtual drive and select the physical disk
drive-related properties.
The number of physical disks required for the virtual disk varies depending on the RAID level. The minimum and maximum numbers of
physical disks required for the RAID level are displayed on the screen.
Protocol — Select the protocol for the disk pool: Serial Attached SCSI (SAS), Serial ATA (SATA), or NVM Express (NVMe).
SAS drives are used for high performance, while SATA drives are used for a more cost-effective solution. A disk pool is a logical
grouping of physical disk drives on which one or more virtual drives can be created. The protocol is the type of technology used to
implement RAID.
Media Type — Select the media type for the disk pool: Hard Disk Drives (HDD) or Solid State Disks (SSD). HDDs use traditional
rotational magnetic media for data storage and SSDs implement flash memory for data storage.
Disk Boot Size — Select one of the following disk block sizes:
512 — indicates that the 512 bytes block size hard drives (HDD) are selected.
4K — indicates that the 4K block size hard disk drives (HDD) are selected. 4K block HDDs allow the faster data transfer with
fewer commands.
T10 Protection Information (T10 PI) Capability— It is known as DIF (Data Integrity Fields) and the supporting HDDs are referred
to DIF drives. The T10 enabled HDDs validates and stores the data integrity fields for each block. It performs this action when you
write the data on the disk and return these values on a read request. When you read or write the data from the HDD, the data is
checked for the errors. Select one of the following types of T10 protection information capabilities:
All — indicates that both the T10 PI capable and non-capable HDDs are selected.
T10 PI Capable — indicates that only T10 PI capable HDDs are selected.
Non-T10 Capable — indicates that only non-T10 capable HDDs are selected.
NOTE: PERC 9 with version 9.3.2 and above doesn’t support T10 PI capabilities.
Encryption Capability — Select Yes to enable encryption capability.
Encryption Protocol — Select the type of encryption protocol. Select one of the following types of encryption protocol type:
TCG Enterprise SSC — indicates only TCG Enterprise SSC Capable drives are selected.
TCG Opal SSC — indicates only TCG Opal SSC Capable drives are selected.
Non-Encryption Capable — indicates only non-encryption capable drives are selected.
Select Span Length — Select the span length. The span length value refers to the number of physical disk drives included in each
span. Span length applies only to RAID 10, RAID 50, and RAID 60. The Select Span Length — Setting span length is only supported
in RAID 10, RAID 50, and RAID 60. And in a RAID 10 configuration, the default value is set to 2 and the option Span Length is not
available is the storage controller supports Uneven span.
Select the physical disk-drives using the check boxes at the bottom of the screen. The physical disk-drive selection must meet the
requirements of the RAID level and span length. To select all the physical disk-drives, click Select All. After you select the option, the
option changes to Deselect.
Configuración de atributos del disco virtual
Utilice esta página para especificar los siguientes valores de los atributos de la unidad virtual:
Size (Tamaño): especifique el tamaño de la unidad virtual.
Stripe Element Size (Tamaño del elemento de la sección): seleccione el tamaño del elemento de la sección. Este tamaño
constituye la cantidad de espacio en la unidad que una sección consume en cada unidad de disco físico de la sección. La lista Stripe
Element Size (Tamaño del elemento de la sección) puede contener más opciones que las que se muestran inicialmente en la
pantalla. Utilice las teclas de flecha hacia arriba y flecha hacia abajo para ver todas las opciones disponibles.
Read Policy (Política de lectura): seleccione la política de lectura:
Read Ahead (Lectura anticipada): la controladora lee los sectores secuenciales de las unidades virtuales cuando busca datos.
La política Lectura anticipada puede mejorar el rendimiento del sistema si los datos se escriben en sectores secuenciales de las
unidades virtuales.
No Read Ahead (Sin lectura anticipada): la controladora no utiliza la política Lectura anticipada. La política Sin lectura
anticipada puede mejorar el rendimiento del sistema si los datos son aleatorios y no están escritos en sectores secuenciales.
Adaptive Read Ahead (Lectura anticipada adaptativa): la controladora inicia la política Lectura anticipada solo si la lectura más
reciente requiere sectores secuenciales accedidos de la unidad de disco. Si la lectura más reciente requiere sectores de acceso
aleatorio de la unidad de disco, la controladora utilizará la política Sin lectura anticipada.
Write Policy (Política de escritura): seleccione la política de escritura.
Write Through (Escritura simultánea): la controladora envía una señal de terminación de la solicitud de escritura solo después
de que los datos se escriban en la unidad de disco. La política Escritura simultánea proporciona una mayor seguridad de los datos
44