For Linux operating systems, configure the USB NIC as DHCP on the host operating system before enabling USB NIC.
For vSphere, you must install the VIB file before enabling USB NIC.
NOTE: To configure USB NIC as DHCP in Linux operating system or XenServer, refer to the operating system or hypervisor
documentation.
Installing VIB file
For vSphere operating systems, before enabling the USB NIC, you must install the VIB file.
To install the VIB file:
1. Using Win-SCP, copy the VIB file to /tmp/ folder of the ESX-i host operating system.
2. Go to the ESXi prompt and run the following command:
esxcli software vib install -v /tmp/ iDRAC_USB_NIC-1.0.0-799733X03.vib --no-sig-check
The output is:
Message: The update completed successfully, but the system needs to be rebooted for
the changes to be effective.
Reboot Required: true
VIBs Installed: Dell_bootbank_iDRAC_USB_NIC_1.0.0-799733X03
VIBs Removed:
VIBs Skipped:
3. Reboot the server.
4. At the ESXi prompt, run the command: esxcfg-vmknic l.
The output displays the usb0 entry.
Enabling or disabling OS to iDRAC Pass-through using web
interface
To enable OS to iDRAC Pass-through using Web interface:
1. Go to iDRAC Settings > Connectivity > Network > OS to iDRAC Pass-through.
The OS to iDRAC Pass-through page is displayed.
2. Change the State to Enabled.
3. Select any of the following options for Pass-through Mode:
LOM The OS to iDRAC pass-through link between the iDRAC and the host operating system is established through
the LOM or NDC.
USB NIC The OS to iDRAC pass-through link between the iDRAC and the host operating system is established
through the internal USB bus.
NOTE:
If you set the pass-through mode to LOM, ensure that:
OS and iDRAC are on the same subnet
NIC selection in Network Settings is set to LOM
4. If the server is connected in shared LOM mode, then the OS IP Address field is disabled.
NOTE:
If the VLAN is enabled on the iDRAC, the LOM-Passthrough will only function in shared LOM mode with VLAN
tagging configured on the host.
NOTE:
When Pass-through mode is set to LOM, it is not possible to launch iDRAC from host OS after cold boot.
Configuring iDRAC 105