Table 17. Sensor information using web interface and RACADM (continued)
View sensor information For Using web interface Using RACADM
For power supplies, you can also use
the System.Power.Supply command
with the get subcommand.
For more information, see the iDRAC
RACADM CLI Guide available at https://
www.dell.com/idracmanuals.
Fan Dashboard > > System Health > Fans
CPU Dashboard > System Health > CPU
Memory Dashboard > System Health >
Memory
Intrusion Dashboard > System Health >
Intrusion
Power Supplies > Hardware > Power Supplies
Removable Flash Media Dashboard > System Health >
Removable Flash Media
Temperature Dashboard > System Health >
Power/Thermal > Temperatures
Voltage Dashboard > System Health >
Power/Thermal > Voltages
Monitoring performance index of CPU, memory, and
input output modules
In Dells 14
th
generation Dell PowerEdge servers, Intel ME supports Compute Usage Per Second (CUPS) functionality. The
CUPS functionality provides real-time monitoring of CPU, memory, and I/O utilization and system-level utilization index for the
system. Intel ME allows out-of-band (OOB) performance monitoring and does not consume CPU resources. The Intel ME has a
system CUPS sensor that provides computation, memory, and I/O resource utilization values as a CUPS Index. iDRAC monitors
this CUPS index for the overall system utilization and also monitors the instantaneous utilization index of the CPU, Memory, and
I/O.
NOTE:
CUPS functionality is not supported on following servers:
PowerEdge R240
PowerEdge R240xd
PowerEdge R340
PowerEdge R6415
PowerEdge R7415
PowerEdge R7425
PowerEdge T140
The CPU and chipset have dedicated Resource monitoring Counters (RMC). The data from these RMCs is queried to obtain
utilization information of system resources. The data from RMCs is aggregated by the node manager to measure the cumulative
utilization of each of these system resources that is read from iDRAC using existing intercommunication mechanisms to provide
data through out-of-band management interfaces.
The Intel sensor representation of performance parameters and index values is for complete physical system. Therefore, the
performance data representation on the interfaces is for the complete physical system, even if the system is virtualized and has
multiple virtual hosts.
To display the performance parameters, the supported sensors must be present in the server.
The four system utilization parameters are:
Viewing iDRAC and managed system information