Owners Manual
Table Of Contents
- Dell PowerEdge M830 (For Dell PowerEdge VRTX Enclosure) Owner's Manual
- Dell PowerEdge M830 (for PowerEdge VRTX) system overview
- Documentation resources
- Technical specifications
- Initial system setup and configuration
- Pre-operating system management applications
- Options to manage the pre-operating system applications
- System Setup
- Viewing System Setup
- System Setup details
- System BIOS
- Viewing System BIOS
- System BIOS Settings details
- Boot Settings
- Network Settings
- UEFI iSCSI Settings
- System Security
- Secure Boot Custom Policy Settings
- System Information
- Memory Settings
- Processor Settings
- SATA Settings
- Integrated Devices
- Serial Communication
- System Profile Settings
- Miscellaneous Settings
- iDRAC Settings utility
- Device Settings
- Dell Lifecycle Controller
- Boot Manager
- PXE boot
- Installing server module components
- Safety instructions
- Recommended tools
- Removing and installing a server module
- System cover
- Inside the server module
- Cooling shroud
- Processor blank and DIMM blank
- System memory
- PCIe mezzanine cards
- PCIe mezzanine card support bracket
- Internal dual SD module (optional)
- rSPI card (optional)
- SD vFlash card
- Network daughter card
- Processors
- Hard drives or SSDs
- Hard drive or SSD bay numbering
- Hard drive or SSD installation guidelines
- Removing a hard drive or SSD
- Installing a hard drive or SSD
- Removing a hard drive or SSD blank
- Installing a hard drive or SSD blank
- Shutdown procedure for servicing a hard drive
- Configuring the boot drive
- Removing a 2.5-inch hard drive or SSD from a 2.5-inch hard drive or SSD carrier
- Installing a 2.5-inch hard drive or SSD in a 2.5-inch hard-drive or SSD carrier
- Removing a 1.8-inch SSD from a 1.8-inch SSD carrier
- Installing a 1.8-inch SSD in a 1.8-inch SSD carrier
- Hard-drive or SSD cage
- Hard-drive or SSD backplane
- Removing a 2.5-inch (x4) SAS hard-drive or SSD backplane
- Installing a 2.5-inch (x4) SAS hard-drive or SSD backplane
- Removing a 2.5-inch (x4) SATA hard-drive or SSD backplane
- Installing a 2.5-inch (x4) SATA hard-drive or SSD backplane
- Removing a 2.5-inch (x2) SATA hard drive or SSD plus 2.5-inch (x2) PCIe SSD backplane
- Installing a 2.5-inch (x2) SATA hard drive or SSD plus 2.5-inch (x2) PCIe SSD backplane
- Removing a 1.8-inch (x12) SAS SSD backplane
- Installing a 1.8-inch (x12) SAS SSD backplane
- System battery
- Storage controller card
- Expander card
- System board
- Trusted Platform Module
- Using system diagnostics
- Jumpers and connectors
- Troubleshooting your system
- Getting help
NOTE: This is a Field Replaceable Unit (FRU). Removal and installation procedures should be performed only by Dell
certified service technicians.
NOTE: You must remove the storage controller card to replace a faulty storage controller card or service other components
inside the system.
1. Follow the safety guidelines listed in the Safety instructions section.
2. Follow the procedure listed in the Before working inside your system section.
3. Keep the #2 Phillips screwdriver ready.
4. Remove the following:
a. hard drives or SSDs
b. hard drive backplane or SSD backplane
c. hard drive cage or SSD cage
Steps
1. Loosen the two retention screws on the hard-drive backplane or SSD backplane cable connector and lift it away from the
storage controller card.
CAUTION: To prevent damage to the storage controller card, hold the card only by its edges.
2. Lift the storage controller card away from the system.
Figure 64. Removing the storage controller card
1.
retention screw (2) 2. slot on the storage controller card
3. tab on the storage controller card support bracket 4. standoff (2)
Next steps
1. Install the storage controller card.
2. Follow the procedure listed in the After working inside your system section.
126
Installing server module components