Owners Manual
Table Of Contents
- Dell PowerEdge M830 (For Dell PowerEdge VRTX Enclosure) Owner's Manual
- Dell PowerEdge M830 (for PowerEdge VRTX) system overview
- Documentation resources
- Technical specifications
- Initial system setup and configuration
- Pre-operating system management applications
- Options to manage the pre-operating system applications
- System Setup
- Viewing System Setup
- System Setup details
- System BIOS
- Viewing System BIOS
- System BIOS Settings details
- Boot Settings
- Network Settings
- UEFI iSCSI Settings
- System Security
- Secure Boot Custom Policy Settings
- System Information
- Memory Settings
- Processor Settings
- SATA Settings
- Integrated Devices
- Serial Communication
- System Profile Settings
- Miscellaneous Settings
- iDRAC Settings utility
- Device Settings
- Dell Lifecycle Controller
- Boot Manager
- PXE boot
- Installing server module components
- Safety instructions
- Recommended tools
- Removing and installing a server module
- System cover
- Inside the server module
- Cooling shroud
- Processor blank and DIMM blank
- System memory
- PCIe mezzanine cards
- PCIe mezzanine card support bracket
- Internal dual SD module (optional)
- rSPI card (optional)
- SD vFlash card
- Network daughter card
- Processors
- Hard drives or SSDs
- Hard drive or SSD bay numbering
- Hard drive or SSD installation guidelines
- Removing a hard drive or SSD
- Installing a hard drive or SSD
- Removing a hard drive or SSD blank
- Installing a hard drive or SSD blank
- Shutdown procedure for servicing a hard drive
- Configuring the boot drive
- Removing a 2.5-inch hard drive or SSD from a 2.5-inch hard drive or SSD carrier
- Installing a 2.5-inch hard drive or SSD in a 2.5-inch hard-drive or SSD carrier
- Removing a 1.8-inch SSD from a 1.8-inch SSD carrier
- Installing a 1.8-inch SSD in a 1.8-inch SSD carrier
- Hard-drive or SSD cage
- Hard-drive or SSD backplane
- Removing a 2.5-inch (x4) SAS hard-drive or SSD backplane
- Installing a 2.5-inch (x4) SAS hard-drive or SSD backplane
- Removing a 2.5-inch (x4) SATA hard-drive or SSD backplane
- Installing a 2.5-inch (x4) SATA hard-drive or SSD backplane
- Removing a 2.5-inch (x2) SATA hard drive or SSD plus 2.5-inch (x2) PCIe SSD backplane
- Installing a 2.5-inch (x2) SATA hard drive or SSD plus 2.5-inch (x2) PCIe SSD backplane
- Removing a 1.8-inch (x12) SAS SSD backplane
- Installing a 1.8-inch (x12) SAS SSD backplane
- System battery
- Storage controller card
- Expander card
- System board
- Trusted Platform Module
- Using system diagnostics
- Jumpers and connectors
- Troubleshooting your system
- Getting help
3. Hold the tab on the processor shield and rotate the shield upward and out of the way.
4. Lift the processor out of the socket and leave the release lever up so that the socket is ready for the new processor.
Figure 34. Removing a processor
1.
socket-release lever 1 2. pin–1 corner of the processor
3. processor 4. slot (4)
5. processor shield 6. socket-release lever 2
7. processor socket 8. tab (4)
Next steps
1. If you are removing the processor permanently, install the processor blank.
2. If you are removing the processor permanently, install the processor/DIMM blank. If you are installing a new processor, see
the Installing a processor section.
3. Install a processor.
4. Install the heat sink.
5. Reinstall the cooling shroud.
6. Follow the procedure listed in the After working inside your system section.
Related references
Safety instructions on page 53
Related tasks
Before working inside your system on page 53
Removing the cooling shroud on page 60
Removing a heat sink on page 90
Installing a processor on page 94
Installing server module components
93