c. thermal grease syringe
3. Place the heat sink onto the processor.
4. Tighten one of the four screws to secure the heat sink to the system board.
5. Repeat the procedure for the remaining two screws.
Figure 36. Installing the heat sink
1.
retention screw (4) 2. heat sink
3. processor socket 4. retention screw slot (4)
Next steps
1. Follow the procedure listed in the After working inside your system section.
2. While booting, press F2 to enter System Setup and verify that the processor information matches the new system configuration.
3. Run the system diagnostics to verify that the new processor operates correctly.
Related References
Safety instructions on page 51
Related tasks
Before working inside your system on page 51
Installing a processor on page 92
Installing the cooling shroud on page 59
After working inside your system on page 52
Hard drives or SSDs
Your system supports up to four 2.5 inch SAS/SATA/PCIe SSDs or SAS /SATA hard drives and twelve 1.8-inch SAS SSDs. The hard
drives or SSDs are supplied in special hot-swappable drive carriers that fit in the drive bays and these drives connect to the system board
through the hard-drive or SSD backplane board.
NOTE: Mixing of SSD/SAS/SATA hard drives is not supported.
94 Installing server module components