Users Guide
To congure SNMP alerts, perform the following steps:
1 From the main menu, select Application Settings > Alerts.
2 Click SNMP Conguration.
3 Select Enable to enable the conguration.
4 Enter the Destination Address.
You can congure up to four SNMP destinations.
5 Select the SNMP Version.
The available SNMP versions are:
• SNMP V1
• SNMP V2
NOTE: For MX9116n or MX5108n IOMs, only SNMP V2, is supported.
6 Enter the Community String.
When you congure the community string for SNMP V1, by default, the community string is appended with |common|FibreChannel11.
7 Select the Port Number and click Send to test the SNMP trap.
Conguring sys log alerts
You can congure up to four sys log destinations.
To congure system log alerts, perform the following steps:
1 Click Application Settings > Alerts > Syslog Conguration.
2 Select the Enabled check box corresponding to the required server.
3 Enter the destination address or the hostname.
4 Enter the port number.
38
Logging in to OME-Modular