Users Guide
– 1 Minute
– 10 Minutes
– 30 Minutes
– 1 Hour
– Indenitely
• Conguration Prole tasks:
– Associate server proles—You can associate proles to blade servers. The prole is extracted from the server and is attached to
the slot containing the server.
– Migrate server proles—You can migrate a prole from one server to another. The system unassigns the identity from the rst
server before the migration. If the unassignment fails, the system displays a critical error. You can override the error and force the
migration to a new server.
– Edit server proles—You can edit the prole characteristics that are unique to the device or slot. If a prole is attached to a
compute, the updated prole conguration is propagated to the compute.
– Remove slot associations—You can detach the server prole from the slot.
NOTE: When a compute sled is inserted into a chassis, sometimes the message, "No device image found", is displayed. To
resolve the issue refresh the inventory of the compute sled, manually.
Conguring compute settings
You can congure the following compute settings:
• Network
• Management
Conguring compute network settings
To congure the compute network settings:
1 Click Devices > Compute > View Details > Settings > Network.
2 In the General Settings section, select the LAN Enablement check box to congure the network settings.
3 Congure the IPv4, IPv6, and management VLAN settings.
Conguring compute management settings
To congure the compute management settings:
1 Click Devices > Compute > View Details > Settings > Management.
2 Congure the password to access the iDRAC console and select IPMI over LAN to enable access from OME–Modular to iDRAC,
through BIOS.
Viewing compute hardware
You can view the details of the hardware components that are installed in the compute sled, on the compute Hardware page. The
hardware components include processor, storage controller, and FRU.
NOTE: If the storage controller cards are absent in iDRAC, the storage enclsoure details are not displayed on the Compute >
View Details > Hardware > Storage Enclosure page.
Viewing compute rmware
You can view the rmware list for the compute in the compute Firmware page. Click Devices > Compute > View Details > Firmware.
Managing compute sleds
41