Users Guide
Conguring IOM network settings
The network settings for IOMs include conguring the public management IP for the selected management port.
To congure the networking settings:
1
Click All Devices > I/O Modules > View Details > Settings > Network or Devices > I/O Modules > View Details > Settings >
Network.
2 In the IPv4 Settings section, select Enable IPv4.
3 Enter the IP Address, Subnet Mask, and Gateway for the management port.
The IP Address, Subnet Mask, and Gateway options are enabled only if the Enable DHCP check box is cleared.
4 In the IPv6 Settings section, select Enable IPv6.
5 Enter the IPv6 Address, select the Prex Length.
The IPv6 Address, Prex Length, and Gateway options are enabled only if the Enable Autoconguration check box is cleared.
6 Enter the Gateway for the management port.
The IPv6 Address, Prex Length, and Gateway options are enabled only if the Enable Autoconguration check box is cleared.
NOTE: For tagged or untagged VLAN network, any IPv6 setting congured using OME - Modular may not have the
default gateway. To get the default gateway, go to the respective OS10 CLI and enable Stateless Address
Autoconguration (SLAAC) on the respective tagged or untagged VLAN.
7 In the DNS Server Settings section, enter the Preferred DNS Server, Alternate DNS Server 1, and Alternate DNS Server 2
addresses.
For MXG610s IOMs, you can set the Preferred DNS and Alternate Server 1 and 2 addresses. However, the server address for
Alternate DNS Server 2 is not applied though the response is successful as, MXG610s IOMs support only two server address for DNS
settings.
8 In the Management VLAN section, select Enable VLAN and enter the VLAN ID.
For MXG610s FC IOMs, DHCP works only without VLAN while Static IP works with or without VLAN conguration. To change the IP
conguration from DHCP IP to Static IP, perform the following steps:
a Disable DHCP, congure the static IP, and save the conguration.
b Enable VLAN, congure the VLAN ID, and save the conguration.
Conguring root password
To congure the root password:
1 Click All Devices > I/O Modules > View Details > Settings > Management or Devices > I/O Modules > View Details > Settings >
Management.
The I/O Modules page is displayed.
2 Enter the Host Name and Root Password for the IOM.
Conguring SNMP settings
To congure the SNMP settings:
1 Click All Devices > I/O Modules > View Details > Settings > Monitoring or Devices > I/O Modules > View Details > Settings >
Monitoring.
2 Select Enable SNMP to congure the SNMP version and community string.
Ethernet IO Modules
59