Users Guide

For the MX5108n, ports 9 and 10 are used. Port 10 operates at 40GbE instead of 100GbE because all VLT links must run at the same speed.
Ensure that you use a cable or optic bre that supports 40GbE.
NOTE: You cannot select the ports, and the connection topology is enforced by SmartFabric Services.
NOTE: VLT is supported only on Ethernet and not on FCoE. Physically separate uplinks for LAN and FCoE trac are required for
MX5108n and MX9116n switches.
Upstream network switch requirements
It is recommended, but not required, that PowerEdge MX switches are connected to a pair of redundant upstream switches. While
connecting a pair of switches in Fabric mode to an upstream switch pair, the upstream switch pair must be congured in the following way:
1 Both upstream switches must be connected to each other using technologies such as VLT or VPC.
2 The upstream switch ports must be in a port-channel using LACP.
NOTE
: The LACP option is supported on Ethernet uplinks only.
3 Ensure that a compatible Spanning Tree Protocol is congured. For more information, see the section, Spanning Tree Protocol.
Spanning Tree Protocol
OS10 defaults to RPVST+ as the Spanning Tree protocol. To change STP modes, use the spanning-tree mode command. See the OS10
User Guide for exact steps. Use the spanning-tree mode command to change STP modes. For steps, see the OS10 Enterprise Edition User
Guide.
NOTE
: If the upstream network is running RSTP, change from RPVST+ to RSTP before physically connecting the switches to the
upstream network. Failure to do so may cause a network outage.
68 SmartFabric Services