This section describes the tasks for troubleshooting and resolving issues using the OME–Modular user interface.
• Firmware update is failing
• Storage assignment is failing
• Management role of IOMs is downgraded
• IOM health is downgraded
• Drives on compute sled are not visible
• Storage sleds cannot be applied to IOMs
• Drives in OpenManage are not visible
• iDRAC drive information does not match OpenManage drive information
• The assignment mode of storage sled is unknown
Storage
This section describes the issues that are related to storage sleds and steps to resolve the issues.
Firmware update is failing
1 Firmware update may fail if one or more subcomponents fail to ash during the rmware update process.
2 If an IOM is downgraded owing to a chassis mismatch or faulty subcomponent, the rmware activation fails.
Storage assignment is failing
A storage assignment fails if:
1 The IOMs are currently downgraded.
2 There is only one IOM present.
3 Only one hot-swappable Expander is present on a storage sled.
SAS IOM status is downgraded
Both SAS IOMs are degraded if a:
1 Peer SAS IOM is detected but cannot be communicated with.
2 Firmware Mismatch is detected.
3 Chassis Mismatch is detected.
SAS IOM health is downgraded
The SAS IOM health is downgraded if: