API Guide

Table Of Contents
(CMC) Enterprise license, OpenManage Enterprise Power Manager leverages
information from the OpenManage Enterprise console for platform-level
power management. OpenManage Enterprise Power Manager then communicates
with Integrated Dell Remote Access Controller (iDRAC) or CMC on each
managed server or chassis to provide power-management data, as well as
execution of control policy - making it easy for IT professionals to
identify areas to gain efficiencies and cut wasteful costs. Features
vary by access method and server model - Please contact Sales or refer
to: dell.com/support.",
"InstalledDate": "2019-06-14 21:13:09.487",
"LastUpdatedDate": null,
"LastDisabledDate": null,
"AvailableVersionDetails@odata.navigationLink": "/api/PluginService/
Plugins('2F6D05BE-EE4B-4B0E-B873-C8D2F64A4625')/AvailableVersionDetails"
}
/api/PluginService/Plugins('<PluginId>')/AvailableVersionDetails
This URL returns the plug-in version information.
GET method for AvailableVersionDetails
Description This method returns the plug-in version information.
Privilege VIEW
HTTP response
codes
200
Example
response body
{
"@odata.context": "/api/
$metadata#Collection(PluginService.VersionDetail)",
"@odata.count": 1,
"value": [
{
"@odata.type": "#PluginService.VersionDetail",
"Version": "1.0.0.9",
"Description": "Dell EMC OpenManage Enterprise Power Manager
is an extension to the Dell EMC OpenManage Enterprise console and uses
fine-grained instrumentation to provide increased visibility over power
consumption, anomalies, and utilization. In addition, the Power Manager
extension alerts and reports on thermal events with servers and groups
of servers. This enables increased control, faster response times,
greater accuracy, and broader decision-making intelligence than would
otherwise be possible. When used with Dell EMC PowerEdge servers or
chassis with the required iDRAC Enterprise or Chassis Management Control
(CMC) Enterprise license, OpenManage Enterprise Power Manager leverages
information from the OpenManage Enterprise console for platform-level
power management. OpenManage Enterprise Power Manager then communicates
with Integrated Dell Remote Access Controller (iDRAC) or CMC on each
managed server or chassis to provide power-management data, as well as
execution of control policy - making it easy for IT professionals to
identify areas to gain efficiencies and cut wasteful costs. Features
vary by access method and server model - Please contact Sales or refer
to: dell.com/support.",
"PackageSize": "4191876",
"ReleaseNoteURL": " https://www.dell.com/openmanage-
enterprise-power-manager ",
"MinimumOmeVersionRequired": "3.2.0"
}
]
}