Modular Chassis Hardware Configuration
The MX7000 Modular chassis currently offers two different servers that support NVDIMM-N: MX740c (2-socket) and MX840c
(4-socket). In order for an power loss condition to be detected, the chassis must have at least one Management Module
installed. While not a requirement for NVDIMM-N support, dual Management Modules provide additional redundancy and
robustness to the NVDIMM-N solution.
If a user is operating a chassis with NVDIMM-N equipped servers and a Management Module firmware update is performed, it
is recommended that the chassis be equipped with two Management Modules. If the chassis has a single Management Module,
the NVDIMM-Ns in the server may be placed in read-only mode during the Management Module upgrade.
NVDIMM-N Module Details
Figure 6 is a picture of a typical NVDIMM-N, and it shows the location of status LEDs on the NVDIMM-N. Table 3 describes the
NVDIMM-Ns LED behavior during different modes of operation.
The DIMM has the following key features:
JEDEC compliant DDR4 288-pin NVDIMM-N
16GB RDIMM, PC4-2666
SLC Flash for backup
In-system health monitoring and alert
On-board I
2
C temperature sensor with integrated SPD EEPROM
Figure 7. NVDIMM-N
Table 5. : NVDIMM-N LED Behavior
NVDIMM-N Operation Green LED Blue LED Amber LED
Powered Off Off Off Off
NVDIMM-N going through
power-on and initialization
On Off On
NVDIMM-N is operating
normally
On Slow Blink (every 15 seconds) Off
Save of Restore Operation in
progress
On Fast Blink Off