Users Guide

Table Of Contents
Figure 15. NVDIMM-N Status
NOTE:
1. All NVDIMM-N errors will be reported to the OS and logged in the server System Event Log. NVDIMM-N Health Status
currently only reflects Correctable Error Threshold Exceeded and Uncorrectable Error status on the NVDIMM-N. Other
errors are reported to OS and logged, but are not be reflected in the iDRAC/OM NVDIMM-N Health Status.
2. NVDIMM-N DIMMs are currently reported as DDR4 16GB Single-Rank 2666 DIMMs in the Memory Details page.
DellEMC standard DDR4 16GB RDIMMs are reported as DDR4 16GB Dual-Rank 2666 DIMMs.
BBU Status
Select the Batteries link on the Dashboard to get more information for the NVDIMM-N Battery health. iDRAC will display the
NVDIMM-N Battery status only after BIOS has completed the system inventory (at end of POST), and it has detected that
NVDIMM-Ns are installed in the server. The Battery status will not be reported if NVDIMM-Ns are not installed.
Figure 16. BBU Status
iDRAC NVDIMM-N Management
25