Reference Guide

29 Dell EMC PowerEdge MX SmartFabric Deployment Guide
4. Configure the port channels that connect to the downstream MX9116n FSEs. Then, exit configuration
mode and save the configuration.
Z9100-ON Leaf 1
Z9100-ON Leaf 2
interface port-channel1
description "To MX Chassis"
no shutdown
switchport mode trunk
switchport trunk allowed vlan10
vlt-port-channel 1
interface ethernet1/1/1
description "To MX Chassis-1"
no shutdown
no switchport
channel-group 1 mode active
interface ethernet1/1/3
description "To MX Chassis-2"
no shutdown
no switchport
channel-group 1 mode active
end
write memory
interface port-channel1
description "To MX Chassis"
no shutdown
switchport mode trunk
switchport trunk allowed vlan10
vlt-port-channel 1
interface ethernet1/1/1
description "To MX Chassis-1"
no shutdown
no switchport
channel-group 1 mode active
interface ethernet1/1/3
description "To MX Chassis-2"
no shutdown
no switchport
channel-group 1 mode active
end
write memory