Reference Guide

47 Dell EMC PowerEdge MX SmartFabric Deployment Guide
Dot1q Tunnel 1 no no
Switchport Isolated 1 0 0
vPC card type 1 N9K TOR N9K TOR
Allowed VLANs - 1,10 1,10
Local suspended VLANs - - -
8.3.3 show lldp neighbors
The show lldp neighbors command provides information about lldp neighbors. In this case Eth1/1 and
Eth1/3 are connected to the two MX9116n FSEs, C160A2 and C140A1. The remaining links, Eth1/29 and
Eth1/31, represent the VLTi connection.
NX3232C-Leaf1(config)# show lldp neighbors
Capability codes:
(R) Router, (B) Bridge, (T) Telephone, (C) DOCSIS Cable Device
(W) WLAN Access Point, (P) Repeater, (S) Station, (O) Other
Device ID Local Intf Hold-time Capability Port ID
S3048-ON mgmt0 120 PBR ethernet1/1/45
C160A2 Eth1/1 120 PBR ethernet1/1/41
C140A1 Eth1/3 120 PBR ethernet1/1/41
NX3232C-Leaf2 Eth1/29 120 BR Ethernet1/29
NX3232C-Leaf2 Eth1/31 120 BR Ethernet1/31
Total entries displayed: 5
8.3.4 show spanning-tree summary
The show spanning-tree summary command validates that STP is enabled on the leaf switches. All
interfaces are shown as forwarding.
NX3232C-Leaf1# show spanning-tree summary
Switch is in rapid-pvst mode
Root bridge for: VLAN0010
Port Type Default is disable
Edge Port [PortFast] BPDU Guard Default is disabled
Edge Port [PortFast] BPDU Filter Default is disabled
Bridge Assurance is enabled
Loopguard Default is disabled
Pathcost method used is short
STP-Lite is disabled
Name Blocking Listening Learning Forwarding STP Active
---------------------- -------- --------- -------- ---------- ----------
VLAN0001 0 0 0 2 2
VLAN0010 0 0 0 2 2
---------------------- -------- --------- -------- ---------- ----------
2 vlans 0 0 0 4 4