Reference Guide

58 Dell EMC PowerEdge MX SmartFabric Deployment Guide
Server templates created
9.3.4.2 Add VLANs to the server templates
After successfully creating server templates, associate each template with VLANs as follows:
1. On the Configuration > Deploy page, select a server template previously created such as MX740c
with QLogic QL41232HMKR NIC.
2. Click the Edit Network button.
3. In the Edit Network window, complete the following:
a. For both ports, if they will be untagged members of a VLAN, select the VLAN from the drop-down
box under Untagged Network. No ports are untagged in this example.
b. For both ports, select the VLANs they are tagged members of in the drop-down box under
Tagged Network. Both ports are tagged members of all six VLANs in this example as shown in
Figure 42.
VLANs added to server template