Reference Guide

63 Dell EMC PowerEdge MX SmartFabric Deployment Guide
The Group Topology page shows the MX9116n and MX7116n connections and if any validation errors are
present. On the MX9116n FSEs, ports 1/1/17-18 are used to connect to the MX7116n FEMs. Ports 1/1/37-40
are used for the VLTi.
9.5.1.2 Show the SmartFabric status
The overall health of the SmartFabric is viewed as follows:
1. Open the OME-M console.
2. From the navigation menu, click Devices > Fabric.
3. Click the fabric name, for example, SmartFabric1, to expand the details of the fabric.
The overall status of the fabric is in the upper left corner of the page as shown in Figure 46.
Fabric status details
The left pane of the Overview tab lists Uplinks, Switches, Servers, and ISL Links. Click the Switches link
to view the switch health status as shown in Figure 47.
SmartFabric switch status