Reference Guide

66 Dell EMC PowerEdge MX SmartFabric Deployment Guide
9.5.1.3 Show port status
The OME-M console can be used to show MX9116n FSE port status, toggle administrative states, configure
breakouts, MTU settings, and auto-negotiation.
1. Open the OME-M console.
2. From the navigation menu, click Devices > I/O Modules.
3. Click an IOM name for the first MX9116n, for example, IOM-A1. The IOM Overview page for that
device is displayed.
4. On the IOM Overview page, click Hardware > Port Information.
Figure 51 shows ports 1/1/1, 1/1/5, 1/71/1 and 1/71/3 are up. Ports 1/1/1 and 1/1/5 are connected to the
compute sleds in the local chassis. Ports 1/71/1 and 1/71/3, in port group 1/1/1, are connected to the compute
sleds in the opposite chassis via the MX7116n FEM.
The figure also shows the uplinks to the Cisco ACI leafs, using port channel 1, are up. It also shows the VLTi
ports, using port channel 1000, are up.
IOM port information