BIOS Error Messages
When BIOS detects an NVDIMM-N related error during POST, BIOS displays an F1/F2 prompt and a corresponding error
message. Multiple messages will appear when multiple errors were detected. BIOS will also log an event for each error in the
Server System Event Log (SEL) and Life Cycle Log (LCL). Please refer to the JEDEC JESD245B spec for more information on
each NVDIMM-N related failure. NVDIMM-N [Location] is the memory slot location as shown in Figure 5.
UEFI0302* NVDIMM-N Not Ready or Not Responding on NVDIMM-N located at [Location].
This NVDIMM-N module will be set to read only mode. Remove input power to the system, reseat the NVDIMM-N module, and
restart the server. If the issue persists, replace the faulty memory module identified in the message.
UEFI0302* Save Error on NVDIMM-N located at [Location].
This NVDIMM-N module will be set to read only mode. Remove input power to the system, reseat the NVDIMM-N module, and
restart the server. If the issue persists, replace the faulty memory module identified in the message.
UEFI0302* Restore Error on NVDIMM-N located at [Location].
This NVDIMM-N module will be set to read only mode. Remove input power to the system, reseat the NVDIMM-N module, and
restart the server. If the issue persists, replace the faulty memory module identified in the message.
UEFI0302 Arm Error on NVDIMM-N located at [Location].
This NVDIMM-N module will be set to read only mode. Remove input power to the system, reseat the NVDIMM-N module, and
restart the server. If the issue persists, replace the faulty memory module identified in the message.
UEFI0302* Erase Error on NVDIMM-N located at [Location].
This NVDIMM-N module will be set to read only mode. Remove input power to the system, reseat the NVDIMM-N module, and
restart the server. If the issue persists, replace the faulty memory module identified in the message.
UEFI0302 Factory Default Error on NVDIMM-N located at [Location].
This NVDIMM-N module will be set to read only mode. Remove input power to the system, reseat the NVDIMM-N module, and
restart the server. If the issue persists, replace the faulty memory module identified in the message.
UEFI0302 Set Event Notification Error on NVDIMM-N located at [Location].