Dell™ PowerEdge™ R210 Systems Getting Started With Your System 系统使用入门 Mengaktifkan Sistem Anda はじめに 시스템시작하기
Dell™ PowerEdge™ R210 Systems Getting Started With Your System Regulatory Model E10S Regulatory Type E10S001 w w w. d e l l . c o m | s u p p o r t . d e l l .
Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make better use of your computer. CAUTION: A CAUTION indicates potential damage to hardware or loss of data if instructions are not followed. WARNING: A WARNING indicates a potential for property damage, personal injury, or death. ____________________ Information in this document is subject to change without notice. © 2009 Dell Inc. All rights reserved.
Installation and Configuration WARNING: Before performing the following procedure, review the safety instructions that came with the system. Unpacking the System Unpack your system and identify each item. Installing the Rails and System in a Rack CAUTION: If installed in a closed or multi-unit rack assembly, the operating ambient temperature of the rack environment may be greater than room ambient.
Optional – Connecting the Keyboard, Mouse, and Monitor Connect the keyboard, mouse, and monitor (optional). The connectors on the back of your system have icons indicating which cable to plug into each connector. Be sure to tighten the screws (if any) on the monitor's cable connector. Connecting the Power Cable Connect the system’s power cable to the system and, if a monitor is used, connect the monitor’s power cable to the monitor.
Securing the Power Cable Bend the system power cable as shown in the illustration and secure the cable in the retention clip. Plug the other end of the power cable into a grounded electrical outlet or a separate power source such as an uninterrupted power supply (UPS) or a power distribution unit (PDU). Turning On the System Press the power button on the system and the monitor. The power indicators should light.
Installing the Optional Bezel Install the bezel (optional). Complete the Operating System Setup If you purchased a preinstalled operating system, see the operating system documentation that ships with your system. To install an operating system for the first time, see the installation and configuration documentation for your operating system. Be sure the operating system is installed before installing hardware or software not purchased with the system.
• Microsoft Windows Small Business Server 2008 (x64) Standard and Premium Editions • Microsoft Windows® Essential Business Server (x64) Standard and Premium Editions • Microsoft Windows Server 2003 R2 32-bit (x86) Standard and Enterprise Editions • Microsoft Windows Server 2003 R2 (x64) Standard and Enterprise Editions • Microsoft Windows Server® 2008 Hyper-V™ • Microsoft Hyper-V Server 2008 • Red Hat® Enterprise Linux® 5.3 (x86_64) • Red Hat Enterprise Linux 5.
Obtaining Technical Assistance If you do not understand a procedure in this guide or if the system does not perform as expected, see your Hardware Owner’s Manual. Dell™ offers comprehensive hardware training and certification. See www.dell.com/training for more information. This service may not be offered in all locations.
Memory (continued) Memory module capacities 1 GB, 2 GB, or 4GB Minimum RAM 1 GB Maximum RAM 16 GB Drives Hard drives Up to two 3.5-inch cabled SAS or SATA internal drives or Up to two 2.5-inch cabled SAS, SATA, or SSD internal drives Optical drive One optional internal slimline SATA DVD-ROM or DVD+/-RW drive NOTE: DVD devices are data only Optional external USB DVD-ROM Connectors Back NIC Two RJ-45 (for integrated 1-GB NICs) Serial 9-pin, DTE, 16550-compatible USB Two 4-pin, USB 2.
Video Video type Matrox G200, integrated in Winbond WPCM450 Video memory 8 MB Power AC power supply (per power supply) Wattage 250 W Voltage 100-240 VAC, 50/60 Hz, 4-2 A Heat dissipation 1039 BTU/hr maximum Maximum inrush current Under typical line conditions and over the entire system ambient operating range, the inrush current may reach 25 A Batteries System battery CR 2032 3.0-V lithium ion coin cell Physical Height 4.24 cm (1.67 in) Width 43.4 cm (17.09 in) Depth 39.37 cm (15.
Environmental (continued) Relative humidity Operating 20% to 80% (noncondensing) with a maximum humidity gradation of 10% per hour Storage 5% to 95% (noncondensing) Maximum vibration Operating 0.26 Grms at 5–350 Hz for 15 min Storage 1.54 Grms at 10–250 Hz for 15 min Maximum shock Operating One shock pulse in the positive z axis (one pulse on each side of the system) of 31 G for 2.
12 Getting Started With Your System
Dell™ PowerEdge™ R210 系统 系统使用入门 管制型号 E10S 管制类型 E10S001 w w w. d e l l . c o m | s u p p o r t . d e l l .
注、小心和警告 注:“注”表示可以帮助您更好地使用计算机的重要信息。 小心:“小心”表示如果不遵循说明,就有可能损坏硬件或导致数据 丢失。 警告: “警告”表示可能会造成财产损失、人身伤害甚至死亡。 ____________________ 本说明文件中的信息如有更改,恕不另行通知。 © 2009 Dell Inc. 版权所有,翻印必究。 未经 Dell Inc. 书面许可,严禁以任何形式复制这些材料。 本文中使用的商标:Dell、DELL 徽标和 PowerEdge 是 Dell Inc. 的商标; Intel 和 Xeon 是 Intel Corporation 在美国 和其它国家和地区的注册商标; Microsoft、 Hyper-V、 Windows 和 Windows Server 是 Microsoft Corporation 在美国和 / 或其它国家和地区的商标或注册商标; Red Hat 和 Red Hat Enterprise Linux 是 Red Hat, Inc. 在美国和其它国家 / 地区的注册商标; SUSE 是 Novell Inc.
安装和配置 警告:执行下列步骤之前,请阅读系统随附的安全说明。 打开系统包装 打开系统包装并识别每件物品。 在机架中安装滑轨和系统 小心:如果在封闭或多部件的机架部件中安装,则机架环境的操作环境温度 可能会高于室温。因此,当在与制造商指定的最大环境温度 (Tma) 相当的环 境中安装设备时应将此因素考虑在内。请参阅第 20 页上的“技术规格”。 遵循系统随附的安全说明和机架安装说明组装滑轨并在机架中安装系统。 系统使用入门 15
可选 – 连接键盘、鼠标和显示器 连接键盘、鼠标和显示器(可选)。 系统背面的连接器附有图标,这些图标指示了要插入每个连接器的电缆。 确保拧紧显示器的电缆连接器上的螺钉(如果有)。 连接电源电缆 将系统电源电缆连接至系统,如果使用显示器,将显示器电源电缆连接至显 示器。 16 系统使用入门
固定电源电缆 如图所示,将系统电源电缆弯曲图中的形状,并使用固定夹固定好电缆。 将电源电缆的另一端插入接地的电源插座或单独的电源,如不间断电源设备 (UPS) 或配电装置 (PDU)。 开启系统 按下系统和显示器的电源按钮。电源指示灯将会亮起。 系统使用入门 17
安装可选挡板 安装挡板(可选)。 完成操作系统安装 如果购买了预安装的操作系统,请参阅随系统提供的操作系统说明文件。 第一次安装操作系统时,请参阅操作系统的安装和配置说明文件。请确保先 安装操作系统,然后再安装未预装的硬件或软件。 支持的操作系统 18 • Microsoft® Windows Server® 2008 R2 (x64) Web、Standard、 Foundation 及 Enterprise 版 • Microsoft Windows Server 2008 SP2 (x86) Web、Standard 及 Enterprise 版 • Microsoft Windows Server 2008 SP2 (x64) Web、Standard 及 Enterprise 版 • Microsoft Windows Server 2008 x32 位 (x86) Web、Standard 及 Enterprise 版 • Microsoft Windows Server 2008 (x64) Web、Standard、Foundation 及 Enterprise 版
• Microsoft Windows® Essential Business Server (x64) Standard 及 Premium 版 • Microsoft Windows Server 2003 R2 32 位 (x86) Standard 及 Enterprise 版 • • Microsoft Windows Server 2003 R2 (x64) Standard 及 Enterprise 版 Microsoft Windows Server® 2008 Hyper-V™ • Microsoft Hyper-V Server 2008 • Red Hat® Enterprise Linux® 5.3 (x86_64) • Red Hat Enterprise Linux 5.3 (x86) • SUSE® Linux Enterprise Server 11 (x86_64) 注:有关支持的操作系统的最新信息,请参阅 www.dell.
技术规格 处理器 处理器类型 Intel® Xeon® 处理器 3400 系列 扩充总线 总线类型 PCI Express 第 2 代 扩充槽 一个全高、半长 x16 链路 内存 体系结构 1066 和 1333 MHz DDR3 非缓冲错误纠正代 码 (ECC) DIMMs 内存模块插槽 四个 240 针插槽 内存模块容量 1GB、2 GB 或 4GB 最小 RAM 1 GB 最大 RAM 16 GB 驱动器 硬盘驱动器 至多两个 3.5 英寸电缆连接型 SAS 或 SATA 内 部驱动器 或 至多两个 2.
连接器 背面 NIC 两个 RJ-45(用于集成的 1 GB NIC) 串行 9 针、DTE、16550 兼容连接器 USB 两个 4 针、USB 2.0 兼容连接器 视频 15 针 VGA 连接器 eSATA 一个 7 针连接器 正面 视频 15 针 VGA 连接器 USB 两个 4 针、USB 2.0 兼容连接器 内部 USB 两个 4 针、USB 2.0 兼容连接器 视频 视频类型 集成在 Winbond WPCM450 中的 Matrox G200 视频内存 8 MB 电源 交流电源设备(每个电源设备) 功率 250 W 电压 100-240 VAC,50/60 Hz,4-2 A 散热 最大 1039 BTU/ 小时 最大涌入电流 在典型的线路条件下和整个系统运行范围内, 涌入电流可达 25 A。 电池 系统电池 CR 2032 3.
物理 高度 4.24 厘米(1.67 英寸) 宽度 43.4 厘米(17.09 英寸) 厚度 39.37 厘米(15.5 英寸) 重量(最大配置) 8.058 公斤(17.77 磅) 环境参数 注:有关特定系统配置的环境测量值的其它信息,请参阅 www.dell.com/environmental_datasheets。 温度 运行时 10° 到 35 °C(50° 到 95 °F),最大温度 变化梯度为每小时 10°C 注:海拔高度在 2950 英尺以上时,最高操作 温度按 1 华氏度 /550 英尺降低。 存储时 – 40° 到 65 °C(– 40° 到 149 °F), 最大温度梯度为每小时 20 °C 相对湿度 运行时 20% 至 80%(非冷凝),最大湿度梯度为每小 时 10% 存储时 5% 至 95%(非冷凝) 最大振动 22 运行时 在 5 - 350 Hz、0.26 Grms 时,可持续 15 分钟 存储时 在 10 - 250 Hz、1.
环境参数 (续) 最大撞击 运行时 z 轴正方向上可承受一个 31 G 的撞击脉冲 (系统每一面承受一个脉冲),在操作方向最 多可持续 2.6 毫秒 存储时 x、y 和 z 轴正负方向上可承受连续六 个 71 G 的撞击脉冲(系统每一面承受一个 脉冲),最长可持续 2 毫秒 x、y 和 z 轴正负方向上可承受连续六个 32 G 的正弦波撞击脉冲(系统每一面承受一个 脉冲),速度变化为每秒 270 英寸(每秒 686 厘米) 海拔高度 运行时 -16 至 3,048 米(-50 至 10,000 英尺) 注:海拔高度在 2950 英尺以上时,最高操作 温度按 1 华氏度 /550 英尺降低。 存储时 -16 至 10,600 米(-50 至 35,000 英尺) 气载污染物级别 分类 G2 或更低(根据 ISA-S71.
24 系统使用入门
Sistem Dell™ PowerEdge™ R210 Mengaktifkan Sistem Anda Model Regulasi E10S Tipe Regulasi E10S001 w w w. d e l l . c o m | s u p p o r t . d e l l .
Catatan, Perhatian dan Peringatan CATATAN: CATATAN menunjukkan informasi penting yang membantu Anda untuk menggunakan komputer dengan lebih baik. PERHATIAN: PERHATIAN menunjukkan kemungkinan kerusakan pada perangkat keras atau hilangnya data jika petunjuk tidak diikuti. PERINGATAN: PERINGATAN menunjukkan kemungkinan kerusakan barang, cedera tubuh, atau kematian. ____________________ Informasi dalam dokumen ini dapat berubah tanpa pemberitahuan. © 2009 Dell Inc. Hak cipta dilindungi undang-undang.
Instalasi dan Konfigurasi PERINGATAN: Sebelum melakukan prosedur berikut, bacalah petunjuk keselamatan yang disertakan dengan sistem. Membuka kemasan Sistem Buka kemasan sistem Anda dan kenali masing-masing barang. Memasang Rel dan Sistem dalam Rak PERHATIAN: Jika diinstal pada rangkaian rak tertutup atau multiunit, suhu pengoperasian normal lingkungan rak mungkin lebih besar daripada suhu normal ruangan.
Opsional – Menghubungkan Keyboard, Mouse, dan Monitor Hubungkan keyboard, mouse, dan monitor (opsional). Konektor di bagian belakang sistem Anda ditandai dengan ikon yang menunjukkan kabel mana yang harus ditancapkan ke masing-masing konektor. Pastikan untuk mengencangkan sekrup (jika ada) pada konektor kabel monitor. Menghubungkan Kabel Daya Hubungkan kabel daya sistem ke sistem dan, jika menggunakan monitor, hubungkan kabel daya monitor ke monitor.
Mengamankan Kabel Daya Bengkokkan kabel daya sistem seperti ditunjukkan pada gambar kemudian tempelkan kabel pada klip pengikat. Tancapkan ujung kabel daya yang lain ke stopkontak listrik yang ditanahkan atau sumber daya terpisah seperti catu daya tak terputus (UPS) atau unit distribusi daya (PDU). Menyalakan Sistem Tekan tombol daya pada sistem dan monitor. Indikator daya seharusnya menyala.
Memasang Bezel Opsional Pasang bezel (opsional). Menyelesaikan Pemasangan Sistem Operasi Jika Anda membeli sistem operasi yang telah terinstal, lihat dokumentasi sistem operasi yang dikirimkan dengan sistem Anda. Untuk menginstal sistem operasi untuk pertama kalinya, lihat dokumentasi instalasi dan konfigurasi untuk sistem operasi Anda. Pastikan bahwa sistem operasi telah terinstal sebelum Anda menginstal perangkat keras atau perangkat lunak yang tidak dibeli bersama sistem.
• Microsoft Windows Small Business Server 2008 (x64) Edisi Standard dan Premium • Microsoft Windows® Essential Business Server (x64) Edisi Standard dan Premium • Microsoft Windows Server 2003 R2 32-bit (x86) Edisi Standard and Enterprise • Microsoft Windows Server 2003 R2 (x64) Edisi Standard dan Enterprise • Microsoft Windows Server® 2008 Hyper-V™ • Microsoft Hyper-V Server 2008 • Red Hat® Enterprise Linux® 5.3 (x86_64) • Red Hat Enterprise Linux 5.
Mendapatkan Bantuan Teknis Jika Anda tidak memahami suatu prosedur dalam panduan ini atau jika sistem tidak bekerja seperti yang diharapkan, lihat Panduan Pemilik Perangkat Keras. Dell™ menyediakan pelatihan dan sertifikasi perangkat lunak yang komprehensif. Lihat www.dell.com/training untuk informasi lebih lanjut. Layanan ini mungkin tidak tersedia di semua lokasi.
Konektor Belakang NIC Dua RJ-45 (untuk NIC terpadu 1-GB) Serial 9-pin, DTE, kompatibel dengan 16550 USB Dua 4-pin, memenuhi standar USB 2.0 Video VGA 15-pin eSATA Satu konektor 7-pin Depan Video VGA 15-pin USB Dua 4-pin, memenuhi standar USB 2.0 Internal USB Dua 4-pin, memenuhi standar USB 2.
Fisik Tinggi 4,24 cm (1,67 inci) Lebar 43,4 cm (17,09 inci) Tebal 39,37 cm (15,5 inci) Berat (konfigurasi maksimum) 8,058 kg (17,77 pon) Lingkungan CATATAN: Untuk informasi lebih lanjut mengenai kondisi lingkungan untuk konfigurasi sistem spesifik, lihat www.dell.com/environmental_datasheets. Suhu Pengoperasian 10° s/d 35°C (50° s/d 95°F) dengan perubahan suhu maksimum 10°C per jam CATATAN: Pada ketinggian di atas 899,16 m (2.950 ft), suhu pengoperasian maksimum berkurang 1°F/167,64 m (550 ft).
Lingkungan (bersambung) Guncangan maksimum Pengoperasian Satu pulsa guncangan pada sumbu z positif (satu pulsa pada setiap sisi sistem) sebesar 31 G selama 2,6 mdtk dalam orientasi pengoperasian Penyimpanan Enam pulsa guncangan berturut-turut pada sumbu x, y, dan z positif dan negatif (satu pulsa pada setiap sisi sistem) sebesar 71 G selama hingga 2 mdtk Enam pulsa guncangan berturut-turut pada sumbu x, y, dan z positif dan negatif (satu pulsa pada setiap sisi sistem) sebesar 32G pulsa gelombang kotak bi
36 Mengaktifkan Sistem Anda
Dell™ PowerEdge™ R210 システム はじめに 認可モデル E10S 認可タイプ E10S001 w w w. d e l l . c o m | s u p p o r t . d e l l .
メモ、注意、警告 メモ:コンピュータを使いやすくするための重要な情報を説明してい ます。 注意:手順に従わない場合は、ハードウェアの損傷やデータの損失の可能 性があることを示しています。 警告: 物的損害、けが、または死亡の原因となる可能性があることを示 しています。 ____________________ 本書の内容は予告なく変更されることがあります。 © 2009 すべての著作権は Dell Inc. にあります。 Dell Inc. の書面による許可のない複製は、いかなる形態においても厳重に禁じられてい ます。 本書に使用されている商標:Dell、DELL ロゴ、および PowerEdge は Dell Inc.
取り付けと設定 警告:次の手順を実行する前に、システムに付属しているマニュアルの 安全にお使いいただくための注意事項をお読みください。 システムの開梱 システムを箱から取り出し、同梱品がすべて揃っていることを確認し ます。 ラックへのレールとシステムの取り付け 注意:閉ざされたラックアセンブリ、または複数ユニットのラックアセン ブリに設置した場合、ラック動作時の周囲温度が室内の周囲温度を上回る ことがあります。そのため、設置環境が製造元の指定する最大周囲温度に 適合している場合でも、考慮が必要です。詳細については、44 ページの 「仕様」を参照してください。 レールの組み立てとラックへのシステムの取り付けの際は、システムに 付属しているマニュアルの安全にお使いいただくための注意事項および ラックへの取り付け手順に従ってください。 はじめに 39
オプション – キーボード、マウス、モニターの接続 キーボード、マウス、モニター(オプション)を接続します。 システム背面のコネクタには、どのケーブルを各コネクタに接続するか を示すアイコンがあります。モニターのケーブルコネクタにネジがある 場合は、必ず締めてください。 電源ケーブルの接続 システムの電源ケーブルをシステムに接続し、モニターを使用する場 合は、モニターの電源ケーブルをモニターに接続します。 40 はじめに
電源ケーブルの固定 システムの電源ケーブルを図のように曲げ、固定クリップで固定し ます。 電源ケーブルのもう一方の端をアースされた電源コンセントまたは UPS (無停電電源装置)や配電装置(PDU)などの電源に接続します。 システムの電源投入 システムとモニターの電源ボタンを押します。電源インジケータが点灯 します。 はじめに 41
ベゼル(オプション)の取り付け ベゼル(オプション)を取り付けます。 OS のセットアップの完了 システムに OS がプリインストールされている場合は、システムに同梱 の OS のマニュアルを参照してください。OS を初めてインストールす る場合は、お使いの OS のインストールと設定に関するマニュアルを参 照してください。システムとは別途に購入したハードウェアやソフト ウェアのインストールは、OS がインストール済みであることを確認し てから行ってください。 対応 OS • Microsoft® Windows Server® 2008 R2(x64) Web/Standard/Foundation/Enterprise Edition • Microsoft Windows Server 2008 SP2(x86) Web/Standard/Enterprise Edition • Microsoft Windows Server 2008 SP2(x64) Web/Standard/Enterprise Edition • Microsoft Windows Server 2008
• Microsoft Windows Small Business Server 2008(x64) Standard/Premium Edition • Microsoft Windows® Essential Business Server(x64) Standard/Premium Edition • Microsoft Windows Server 2003 R2 32 ビット(x86) Standard/Enterprise Edition • Microsoft Windows Server 2003 R2(x64)Standard/Enterprise Edition • Microsoft Windows Server® 2008 Hyper-V™ • Microsoft Hyper-V Server 2008 • Red Hat® Enterprise Linux® 5.3(x86_64) • Red Hat Enterprise Linux 5.
テクニカルサポートの利用法 本書の手順が理解できない場合やシステムが思ったとおりに動作しない 場合は、 『ハードウェアオーナーズマニュアル』を参照してください。 デルでは広範囲にわたるハードウェアのトレーニングと資格認証を実施 しています。詳細については、www.dell.com/training を参照して ください。このサービスが提供されていない地域もあります。 仕様 プロセッサ プロセッサのタイプ Intel® Xeon® プロセッサ 3400 シリーズ 拡張バス バスのタイプ PCI Express Gen 2 拡張スロット フルハイト、ハーフレングス x16 リンク 1 個 メモリ アーキテクチャ 1066 および 1333 MHz DDR3 バッファなし ECC DIMM メモリモジュールソケット 240 ピンソケット 4 個 メモリモジュールの容量 1 GB、2 GB、または 4GB 最小 RAM 1 GB 最大 RAM 16 GB ドライブ ハードドライブ ケーブル接続済み 3.
コネクタ 背面 NIC RJ-45(内蔵 1 GB NIC 用)コネクタ 2 個 シリアル 16550 互換 9 ピン DTE USB 4 ピン USB 2.0 対応コネクタ 2 個 ビデオ 15 ピン VGA eSATA 7 ピンコネクタ 1 個 前面 ビデオ 15 ピン VGA USB 4 ピン USB 2.0 対応コネクタ 2 個 内蔵 USB 4 ピン USB 2.0 対応コネクタ 2 個 ビデオ ビデオのタイプ Matrox G200(Winbond WPCM450 に内蔵) ビデオメモリ 8 MB 電源 AC 電源ユニット(各電源ユニットにつき) ワット数 250 W 電圧 100-240 VAC、50/60 Hz、4-2 A 熱消費 最大 1,039 BTU/ 時 最大流入電流 通常のラインコンディションのもと、システ ムの動作環境全範囲で、入電量が 25 A に達 することがあります。 バッテリー システムバッテリー 3.
サイズと重量 縦幅 4.24 cm 横幅 43.4 cm 奥行き 39.37 cm 重量(最大構成) 8.058 kg 環境 メモ:特定のシステム構成でのその他の環境条件の詳細については、 www.dell.com/environmental_datasheets を参照してください。 温度 動作時 1 時間当たり最大 10°C の温度変化で 10 ~ 35°C メモ:高度が 900 m を超えると、動作時の許 容最大温度は、168 m ごとに 1 °F ずつ低下し ます。 保管時 1 時間当たり最大 20°C の温度変化で -40 ~ 65°C 相対湿度 動作時 1 時間当たり最大 10 パーセントの湿度変化 で 20 ~ 80 パーセント(結露しないこと) 保管時 5 ~ 95 パーセント(結露しないこと) 最大耐久震度 46 動作時 15 分間にわたり 5 ~ 350 Hz で 0.26 Grms 保管時 15 分間にわたり 10 ~ 250 Hz で 1.
環境 (続き) 最大耐久衝撃 動作時 z 軸の正方向に 2.6 ミリ秒で 31 G の 1 衝撃 パルス(システムの各面に対して 1 パルス) 保管時 x、y、z 軸の正および負方向に 6 連続衝撃パ ルス(システムの各面に対して 1 パルス)、 2 ミリ秒以下で 71 G x、y、z 軸の正および負方向に 6 連続衝撃パ ルス(システムの各面に対して 1 パルス)、 32 G フェアードスクエアパルス波(686 cm / 秒の速度変化) 高度 動作時 –16 ~ 3,048 m メモ:高度が 900 m を超えると、動作時の許 容最大温度は、168 m ごとに 1 °F ずつ低下し ます。 保管時 –16 ~ 10,600 m 空気汚染物質レベル クラス G2 またはそれ未満(ISA-S71.
48 はじめに
Dell™ PowerEdge™ R210 시스템 시스템시작하기 규정 모델 E10S 규정 유형 E10S001 w w w. d e l l . c o m | s u p p o r t . d e l l .
주 , 주의 및 경고 주: 주는 컴퓨터를 보다 효율적으로 사용하는 데 도움이 되는 중요 정보를 제 공합니다. 주의: 주의는 지침을 준수하지 않으면 하드웨어 손상이나 데이터 손실의 위험 이 있음을 알려 줍니다. 경고 : 경고는 재산상의 피해나 심각한 부상 또는 사망을 유발할 수 있는 위험 이 있음을 알려줍니다 . ____________________ 이 문서의 정보는 사전 통보 없이 변경될 수 있습니다. © 2009 Dell Inc. 저작권 본사 소유. Dell Inc.의 서면 승인 없이 어떠한 경우에도 무단 복제하는 것을 엄격히 금합니다. 본 설명서에 사용된 상표인 Dell, DELL 로고 및 PowerEdge는 Dell Inc.의 상표이며, Intel 및 Xeon 은 미국 및 기타 국가에서 Intel Corporation의 등록 상표입니다.
설치 및 구성 경고 : 다음 절차를 수행하기 전에 시스템과 함께 제공되는 안전 지침을 검토 하십시오 . 시스템 포장 풀기 시스템 포장을 풀고 각 항목을 확인합니다. 랙에 레일 및 시스템 설치 주의: 폐쇄형 또는 다중 장치 랙 조립품에 설치된 경우 랙 환경의 작동 주변 온 도가 실내 온도보다 높을 수 있습니다. 따라서 제조업체가 지정한 TMA(최대 주변 온도)에 가까운 환경에 장비를 설치할 때는 주의를 기울여야 합니다. 자세한 내용은 56페이지의 "기술 사양"을 참조하십시오. 안전 지침 및 시스템과 함께 제공되는 랙 설치 지침에 따라 레일을 조립하고 시스템을 랙에 설치합니다.
선택사양 – 키보드 , 마우스 및 모니터 연결 키보드, 마우스 및 모니터(선택사양)를 연결합니다. 시스템 후면에 있는 커넥터에는 각 커넥터에 연결될 케이블이 표시된 아이 콘이 있습니다. 모니터의 케이블 커넥터에 있는 나사(해당하는 경우)를 단단 히 고정하십시오. 전원 케이블 연결 시스템의 전원 케이블을 시스템에 연결하고, 모니터를 사용하는 경우 모니 터의 전원 케이블을 모니터에 연결합니다.
전원 케이블 고정 그림과 같이 시스템 전원 케이블을 구부려서 고정 클립으로 케이블을 고정 합니다. 전원 케이블의 반대쪽 끝을 접지된 전원 콘센트나, 무정전 전원 공급 장치 (UPS) 또는 배전 장치(PDU)와 같은 별도의 전원에 연결합니다. 시스템 켜기 시스템과 모니터의 전원 단추를 누릅니다. 그러면 전원 표시등이 켜집니다.
베젤 ( 선택사양 ) 설치 베젤(선택사양)을 설치합니다. 운영 체제 설치 완료 시스템 구입 시 운영 체제가 미리 설치되어 있는 경우 시스템과 함께 제공되 는 운영 체제 설명서를 참조하십시오. 운영 체제를 처음 설치하려면 운영 체 제 설치 및 구성 설명서를 참조하십시오. 시스템과 함께 구입하지 않은 하드 웨어 또는 소프트웨어를 설치하기 전에 운영 체제가 설치되어 있는지 확인 하십시오.
• • • Microsoft Windows Small Business Server 2008(x64) Standard 및 Premium Edition Microsoft Windows® Essential Business Server(x64) Standard 및 Premium Edition Microsoft Windows Server 2003 R2 32비트(x86) Standard 및 Enterprise Edition • Microsoft Windows Server 2003 R2(x64) Standard 및 Enterprise Edition • • Microsoft Windows Server® 2008 Hyper-V™ Microsoft Hyper-V Server 2008 • Red Hat® Enterprise Linux® 5.3(x86_64) • Red Hat Enterprise Linux 5.
기술 지원 얻기 본 안내서의 절차가 이해되지 않거나 시스템이 제대로 작동하지 않을 경우에 는 하드웨어 소유자 설명서를 참조하십시오. Dell™은 포괄적인 하드웨어 교 육 및 인증을 제공합니다. 자세한 내용은 www.dell.com/training을 참조하십 시오. 지역에 따라 이 서비스가 제공되지 않을 수도 있습니다. 기술 사양 프로세서 프로세서 유형 Intel® Xeon® Processor 3400 시리즈 확장 버스 버스 유형 PCI Express Generation 2 확장 슬롯 전체 높이, half-length x16 링크 1개 메모리 아키텍처 1066 및 1333 MHz DDR3 비버퍼형 ECC (Error Correcting Code) DIMM 메모리 모듈 소켓 240핀 4개 메모리 모듈 용량 1 GB, 2 GB 또는 4 GB 최소 RAM 1 GB 최대 RAM 16 GB 드라이브 하드 드라이브 3.
커넥터 후면 NIC RJ-45 (내장형 1GB NIC용) 2개 직렬 9핀, DTE, 16550 호환 USB 4핀 2개, USB 2.0 호환 비디오 15핀 VGA eSATA 7핀 커넥터 1개 전면 비디오 15핀 VGA USB 4핀 2개, USB 2.0 호환 내부 USB 4핀 2개, USB 2.0 호환 비디오 비디오 유형 Winbond WPCM450에 내장된 Matrox G200 비디오 메모리 8 MB 전원 AC 전원 공급 장치(전원 공급 장치마다) 와트 250 W 전압 100-240 VAC, 50/60 Hz, 4-2 A 열 손실 최대 1039 BTU/hr 최대 유입 전류 일반적인 회선 상태 및 전체 시스템 작동 범위에 서 최대 25A의 전류가 유입될 수 있습니다. 전지 시스템 전지 CR 2032 3.
규격 높이 4.24 cm (1.67인치) 너비 43.4 cm (17.09인치) 깊이 39.37 cm (15.5인치) 무게(최대 구성 시) 8.058 kg(17.77lb) 환경 주: 특정 시스템 구성을 위한 환경 측정에 대한 자세한 정보는 www.dell.com/environmental_datasheets를 참조하십시오. 온도 작동 10°~35°C (50°~95°F), 시간당 최고 10°C 의 온도 변화 기준 주: 2,950피트 이상의 고도인 경우 최대 작동 온 도는 1°F/550 ft로 감소됩니다. 보관 –40°~65°C (–40°~149°F), 시간당 최고 20°C의 온도 변화 기준 상대 습도 작동 20 %~80 %(비응축), 시간당 최고 10 %의 습도 변 화 기준 보관 5 %~95 %(비응축) 최대 진동 작동 5~350 Hz에서 15분 동안 0.26 Grms 보관 10~250 Hz에서 15분 동안 1.54 Grms 최대 충격 작동 작동 방향으로 2.
환경 ( 계속 ) 고도 작동 –16~3,048 m(–50~10,000 ft) 주: 2,950피트 이상의 고도인 경우 최대 작동 온 도는 1°F/550 ft로 감소됩니다. 보관 –16~10,600 m(–50~35,000 ft) 공기 중 오염 물질 수준 등급 ISA-S71.
60 시스템 시작 하기