Users Guide
Table Of Contents
- Dell Lifecycle Controller GUI v2.70.70.70 User's Guide
- Contents
- Introduction
- Using Lifecycle Controller
- Operating system deployment
- Monitor
- Hardware inventory view and export
- About view and export current inventory
- About view and export factory-shipped inventory
- Viewing hardware inventory — current or factory shipped
- Exporting hardware inventory — current or factory shipped
- Viewing or exporting hardware inventory after part replacement
- Viewing or exporting current inventory after resetting Lifecycle Controller
- Lifecycle Controller log
- Firmware update
- Configure
- System control panel access options
- Configuring iDRAC
- Configuring system time and date
- Configuring vFlash SD card
- Configuring RAID
- Configuring RAID using software RAID
- Creating a secure virtual disk on a RAID controller
- Key encryption
- Local key encryption mode
- Breaking mirrored drives
- System setup — Advanced Hardware Configuration
- Collect system inventory on restart
- Configuring local FTP server
- Configuring a local USB drive
- Configuring NFS and CIFS servers
- Conditions while configuring HTTP / HTTPS server
- Maintain
- Platform restore
- Backup server profile
- Export server profile
- Import server profile
- Import server license
- Part replacement configuration
- Repurpose or retire system
- Hardware diagnostics
- SupportAssist Collection
- Easy-to-use system component names
- Using the system setup and boot manager
- Troubleshooting and frequently asked questions
Easy-to-use system component names
The following is the list of most commonly used Fully Qualified Device Descriptors (FQDD) used in all the interfaces including
GUI, Redfish, WSMAN, and RACADM.
● ALL
● iDRAC
● System
● LifecycleController
● EventFilters
● BIOS
● NIC
● FC
● RAID
The following table lists the FQDD of the system components and the equivalent easy-to-use names.
Table 13. Easy-to-use Names of System Components
FQDD of System Component Name Easy-to-use Name
RAID.Integrated.1-1 Integrated RAID Controller 1
RAID.Slot.1-1 RAID Controller in Slot 1
NIC.Mezzanine.1B-1 NIC in Mezzanine
NIC.Mezzanine.1C-1
NIC.Mezzanine.1C-2
NIC.Mezzanine.3C-2
NonRAID.Integrated.1-1
Integrated Storage Controller 1
NonRAID.Slot.1-1 Storage Controller in Slot 1
NonRAID.Mezzanine.2C-1 Storage Controller in Mezzanine 1 (Fabric C)
NIC.Embedded.1
NIC.Embedded.2
Embedded NIC 1
Embedded NIC 2
NIC.Embedded.1-1 Embedded NIC 1 Port 1
NIC.Embedded.1-1-1 Embedded NIC 1 Port 1 Partition 1
NIC.Slot.1-1
NIC.Slot.1-2
NIC in Slot 1 Port 1
NIC in Slot 1 Port 2
Video.Embedded.1-1 Embedded Video Controller
HostBridge.Embedded.1-1 Embedded Host Bridge 1
ISABridge.Embedded.1-1 Embedded ISA Bridge 2
8
Easy-to-use system component names 71