Cooling fans
Your system supports:
Up to four cooling fans in a non-redundant power supply unit (PSU) configuration.
Up to five cooling fans in a redundant PSU configuration.
NOTE: Fan 1 must be installed in a redundant power supply configuration and is connect to Power Interposer board (PIB)
NOTE: Hot-swap removal or installation of the fans is not supported.
NOTE: Each fan is listed in the systems management software, referenced by the respective fan number. If there is a
problem with a particular fan, you can easily identify and replace the proper fan by noting the fan numbers on the cooling
fan assembly.
Extracción de un ventilador de refrigeración
Requisitos previos
NOTA: El procedimiento para extraer cada ventilador es el mismo.
1. Extraiga la cubierta de refrigeración.
2. Si procede, extraiga la cubierta de refrigeración.
Pasos
1. Desconecte el cable de alimentación del conector de alimentación de la placa base o la placa mediadora de alimentación.
2. Levanta y extraiga el ventilador del soporte de ventilador de refrigeración.