iDRAC 8/7 v2.70.70.
Notes, cautions, and warnings NOTE: A NOTE indicates important information that helps you make better use of your product. CAUTION: A CAUTION indicates either potential damage to hardware or loss of data and tells you how to avoid the problem. WARNING: A WARNING indicates a potential for property damage, personal injury, or death. © 2019 Dell Inc. or its subsidiaries. All rights reserved. Dell, EMC, and other trademarks are trademarks of Dell Inc. or its subsidiaries.
Contents 1 Introduction............................................................................................................................... 33 New in this release.............................................................................................................................................................. 33 Supported RACADM Interfaces........................................................................................................................................
getsensorinfo........................................................................................................................................................................72 getssninfo............................................................................................................................................................................. 75 getsvctag....................................................................................................................................
vflashsd................................................................................................................................................................................ 151 vflashpartition.....................................................................................................................................................................152 vmdisconnect...............................................................................................................................
cfgSessionManagement................................................................................................................................................... 168 cfgSsnMgtRacadmTimeout (Read or Write)........................................................................................................... 168 cfgSsnMgtConsRedirMaxSessions (Read or Write)...............................................................................................168 cfgSsnMgtWebserverTimeout (Read or Write).....
cfgServerInfo...................................................................................................................................................................... 181 cfgServerName (Read Or Write)................................................................................................................................181 cfgServerNic3MacAddress (Read Only)...................................................................................................................
cfgThermalEnhancedCoolingMode (Read or Write)............................................................................................... 193 cfgIpmiSol........................................................................................................................................................................... 194 cfgIpmiSolEnable (Read or Write).............................................................................................................................
cfgServerPowerLastDayMinTime (Read Only).......................................................................................................203 cfgServerPowerLastDayMaxPower (Read Only)................................................................................................... 204 cfgServerPowerLastDayMaxTime (Read Only)......................................................................................................204 cfgServerPowerLastWeekMinPower (Read Only)................................
cfgIPv6StaticGateway (Read or Write)....................................................................................................................215 cfgIPv6StaticPrefixLength (Read or Write).............................................................................................................215 cfgIPv6StaticAutoConfig (Read/Write)...................................................................................................................
cfgLoggingSELOEMEventFilterEnable (Read or Write)........................................................................................ 226 cfgRacSecurity.................................................................................................................................................................. 226 cfgRacSecCsrCommonName (Read or Write).......................................................................................................
System.Location.Chassis.Name (Read Only).......................................................................................................... 242 System.Location.Chassis.Slot (Read or Write)....................................................................................................... 242 System.OpenIDConnectServer....................................................................................................................................... 242 System.OpenIDConnectServer.
System.Power.Supply.......................................................................................................................................................256 System.Power.Supply.CurrentDraw (Read Only)................................................................................................... 257 System.Power.Supply.FwVer (Read Only).............................................................................................................. 257 System.Power.Supply.[i].
LifecycleController.LCAttributes.UserProxyType (Read and Write)....................................................................270 LifecycleController.LCAttributes.UserProxyUserName (Read or Write).............................................................270 LifecycleController.LCAttributes.VirtualAddressManagementApplication (Read or Write).............................. 270 iDRAC.ActiveDirectory..........................................................................................................
iDRAC.IOIDOpt.VirtualAddressPersistencePolicyNonAuxPwrd (Read or Write)................................................283 iDRAC.IPBlocking.............................................................................................................................................................. 283 iDRAC.IPBlocking.BlockEnable (Read or Write)......................................................................................................283 iDRAC.IPBlocking.FailCount (Read or Write)..................
iDRAC.IPv6.Address2 (Read or Write).....................................................................................................................296 iDRAC.IPv6.Address3 (Read or Write).....................................................................................................................296 iDRAC.IPv6.Address4 (Read or Write)..................................................................................................................... 297 iDRAC.IPv6.Address5 (Read or Write)........
iDRAC.Logging.SELOEMEventFilterEnable (Read or Write)................................................................................ 309 iDRAC.NIC..........................................................................................................................................................................309 iDRAC.NIC.Autoconfig (Read or Write)................................................................................................................... 309 iDRAC.NIC.
iDRAC.RemoteHosts.SMTPServerIPAddress (Read or Write).............................................................................322 iDRAC.RFS......................................................................................................................................................................... 323 iDRAC.RFS.IgnoreCertWarning (Read or Write).................................................................................................... 323 iDRAC.RFS.MediaAttachState (Read Only).........
iDRAC.ServiceModule.WMIInfo (Read or Write).................................................................................................... 335 iDRAC.SmartCard............................................................................................................................................................. 335 iDRAC.SmartCard.SmartCardCRLEnable (Read or Write)....................................................................................336 iDRAC.SmartCard.
iDRAC.USB.PortStatus (Read or Write).................................................................................................................. 347 iDRAC.Telnet.Timeout (Read or Write).................................................................................................................... 347 iDRAC.UserDomain........................................................................................................................................................... 348 iDRAC.UserDomain.
iDRAC.VirtualMedia.KeyEnable (Read or Write).....................................................................................................360 iDRAC.VNCServer............................................................................................................................................................ 360 iDRAC.VNCServer.Enable (Read or Write)............................................................................................................. 360 iDRAC.VNCServer.
BIOS.IntegratedDevices.InternalSdCardRedundancy (Read or Write)................................................................ 374 BIOS.IntegratedDevices.InternalUsb (Read or Write)............................................................................................ 374 BIOS.IntegratedDevices.InternalUsb1 (Read or Write)...........................................................................................374 BIOS.IntegratedDevices.InternalUsb2 (Read or Write)....................................
BIOS.ProcSettings............................................................................................................................................................ 388 BIOS.ProcSettings.CorePerfBoost (Read or Write)...............................................................................................388 BIOS.ProcSettings.DataReuse (Read or Write)......................................................................................................388 BIOS.ProcSettings.
BIOS.ProcSettings.ProcX2Apic (Read or Write).................................................................................................... 402 BIOS.ProcSettings.QpiBandwidthPriority (Read or Write)....................................................................................403 BIOS.ProcSettings.QpiSpeed (Read or Write)........................................................................................................403 BIOS.ProcSettings.RtidSetting (Read or Write)..........................
BIOS.SataSettings.SataPortHModel (Read Only)...................................................................................................416 BIOS.SataSettings.SataPortI (Read or Write)..........................................................................................................417 BIOS.SataSettings.SataPortICapacity (Read or Write).......................................................................................... 417 BIOS.SataSettings.SataPortIDriveType (Read or Write)..............
BIOS.SysProfileSettings.Proc2TurboCoreNum (Read or Write)...........................................................................431 BIOS.SysProfileSettings.ProcC1E (Read or Write)..................................................................................................431 BIOS.SysProfileSettings.ProcCStates (Read or Write)......................................................................................... 432 BIOS.SysProfileSettings.ProcPwrPerf (Read or Write)...............................
FC.FCDevice.PCIDeviceID (Read Only)................................................................................................................... 445 FC.FCTarget...................................................................................................................................................................... 446 FC.FCTarget.BootScanSelection (Read or Write)..................................................................................................446 FC.FCTarget.
NIC.DCBSettings.EnhancedTransmissionSelection (Read Only)..........................................................................458 NIC.DCBSettings.PriorityFlowControl (Read Only)................................................................................................458 NIC.DeviceLevelConfig.....................................................................................................................................................458 NIC.DeviceLevelConfig.EVBModesSupport (Read Only).......
NIC.IscsiFirstTgtParams.FirstTgtChapPwd (Password)........................................................................................ 471 NIC.IscsiFirstTgtParams.FirstTgtIpAddress (Read or Write)................................................................................. 471 NIC.IscsiFirstTgtParams.FirstTgtIpVer (Read or Write)........................................................................................ 472 NIC.IscsiFirstTgtParams.FirstTgtIscsiName (Read or Write).......................
NIC.NICConfig.LegacyBootProto (Read or Write).................................................................................................485 NIC.NICConfig.LnkSpeed (Read or Write).............................................................................................................. 486 NIC.NICConfig.NumberVFAdvertised (Read or Write)..........................................................................................486 NIC.NICConfig.VLanId (Read or Write)...................................
NIC.VndrConfigGroup.VirtWWPN (Read or Write)............................................................................................... 500 NIC.VndrConfigGroup.WWN (Read Only)...............................................................................................................500 NIC.VndrConfigGroup.WWPN (Read Only)............................................................................................................ 500 NIC.VndrConfigPage...................................................
Storage.enclosure.BackplaneRequestedMode (Read or Write)............................................................................ 512 Storage.enclosure.BackplaneType (Read Only).......................................................................................................513 Storage.PhysicalDisk......................................................................................................................................................... 513 Storage.PhysicalDisk.
1 Introduction This document provides information about the RACADM subcommands, supported RACADM interfaces, and property database groups and object definitions for the following: • • iDRAC for Blade Servers iDRAC on Rack and Tower Servers Most of the commands mentioned in this document are applicable for multi-generation servers. That is, the commands are applicable for iDRAC6, iDRAC7, and iDRAC8.
• SSH or Telnet — Also known as Firmware RACADM. Firmware RACADM is accessible by logging in to iDRAC using SSH or Telnet. Similar to Remote RACADM, at the RACADM prompt, directly run the commands without the RACADM prefix. Remote — Supports running RACADM commands from a remote management station such as a laptop or desktop. To run Remote RACADM commands, install the DRAC Tools utility from the OpenManage software on the remote computer.
• To display the supported indexes for a specified group, run: racadm get device. Example racadm get nic.nicconfig NIC.nicconfig.1 [Key=NIC.Integrated.1-1-1#nicconfig] NIC.nicconfig.2 [Key=NIC.Integrated.1-2-1#nicconfig] NIC.nicconfig.3 [Key=NIC.Integrated.1-3-1#nicconfig] NIC.nicconfig.4 [Key=NIC.Integrated.1-4-1#nicconfig] • To display the object list for the specified group, run: racadm get device.. Example racadm get nic.nicconfig.2 [Key=NIC.Integrated.
Option Description --nocertwarn Does not display certificate related warning message. -i Specifies the index number for the indexed group, if applicable. -g Specifies the group name if applicable. -o Specifies the object name if applicable. Using autocomplete feature Use the autocomplete feature to: • • • Display all the available RACADM commands in the alphabetical order on pressing the Tab key at the prompt.
• Example 3: racadm> getl racadm> getled or LEDState: Not-Blinking • Example 4: racadm>> get bios.uefiBootSettings BIOS.UefiBootSettings BIOS.UefiBootSettings.UefiBootSeq BIOS.UefiBootSettings.UefiPxeIpVersion NOTE: In the RACADM autocomplete mode, some of the RACADM commands specific to certain server platforms may not be available. In such scenarios, execute the RACADM command in the normal execution mode.
Supported RACADM Subcommands The following table provides the list of RACADM subcommands and their corresponding interface support. For more information about the RACADM subcommands including syntax and valid entries, see RACADM Subcommand Details. Table 2.
Subcommand iDRAC on Blade Servers Telnet/SSH/Serial Local RACADM Remote RACADM license Yes Yes Yes nicstatistics Yes Yes Yes ping Yes Yes Yes ping6 Yes Yes Yes racdump Yes No Yes racreset Yes Yes Yes racresetcfg Yes Yes Yes remoteimage Yes Yes Yes rollback Yes Yes Yes sensorsettings Yes Yes Yes serveraction Yes Yes Yes set Yes Yes Yes setled Yes Yes Yes setniccfg Yes Yes Yes sshpkauth Yes Yes Yes sslcertupload No Yes Yes sslcertview Yes Ye
Other Documents You May Need In addition to this guide, you can access the following guides available on the Dell Support website at www.dell.com/esmmanuals. To access the documents, click the appropriate product link. • • • • • • The Integrated Dell Remote Access Controller 8 (iDRAC8) User’s Guide provides information about configuring and using an iDRAC to remotely manage and monitor your system and its shared resources through a network.
Contacting Dell NOTE: If you do not have an active Internet connection, you can find contact information on your purchase invoice, packing slip, bill, or Dell product catalog. Dell provides several online and telephone-based support and service options. Availability varies by country and product, and some services may not be available in your area. To contact Dell for sales, technical support, or customer service issues: 1. Go to Dell.com/support. 2. Select your support category. 3.
2 RACADM Subcommand Details This section provides detailed description of the RACADM subcommands including the syntax and valid entries. Topics: • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • 42 Guidelines to Quote Strings Containing Special Characters When Using RACADM Commands Help and help subcommand arp autoupdatescheduler cd cd..
• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • racreset racresetcfg remoteimage rollback sensorsettings serveraction set setled setniccfg sshpkauth sslcertdownload sslcertupload sslcertview sslcertdelete sslcsrgen sslkeyupload sslresetcfg storage swinventory systemconfig systemerase systemperfstatistics techsupreport testemail testtrap testalert traceroute traceroute6 update usercertupload usercertview vflashsd vflashpartition vmdisconnect Guidelines to Quote Strings Containing Specia
NOTE: The - (dash) character cannot be the first character of the string, regardless of whether the string is quoted. There are different escaping rules for double quotation marks. There are different escaping rules for using single quotation mark and double quotation marks. For using double quotation marks: The following characters must be escaped by prepending a backward slash: • • • • • $ (dollar sign) " (double quotation mark) ' (single quotation marks) ` (back quotation mark) \ (backward slash) For e
To use this subcommand, you must have Debug privilege. To use this subcommand, you must have Execute Diagnostic Commands. Synopsis Input Example racadm arp N/A racadm arp Table 5. Output Address HW Type HW Address Mask Device 192.168.1.1 Ether 00:0d:65:f3:7c:bf C eth0 autoupdatescheduler Table 6. Details of autoupdatescheduler Description You can automatically update the firmware of the devices on the server. To run this subcommand, you must have the Server Control privilege.
• -f — Specifies the catalog location and the filename. If the filename is not specified, then the default file that is used is catalog.xml. NOTE: If the file is in a subfolder within the share location, then enter the network share location in the –l option and enter the subfolder location and the filename in the –f option. • • • • • • • -ph — Specifies the FTP/HTTP proxy hostname. -pu — Specifies the FTP/HTTP proxy user name. -pp — Specifies the FTP/HTTP proxy password.
• For HTTPS, run the command: racadm autoupdatescheduler create -u httpuser -p httppwd -l https:// test.com -f cat.xml -ph 10.20.30.40 -pu padmin -pp ppwd -po 8080 -pt http -time 14:30 -dom 1 -rp 5 -a 1 • For TFTP, run the command: racadm autoupdatescheduler create -l tftp://1.2.3.4 -f cat.xml.gz time 14:30 -dom 1 -rp 5 -a 1 • To view AutoUpdateScheduler parameter: racadm autoupdatescheduler view hostname = 192.168.0 sharename = nfs sharetype = nfs catalogname = Catlog.
Input racadm> cd.. Output To traverse back to the previous directory, use the command. Example • Example 1: To traverse back from power to system object: • • Input: racadm/power> cd.. Output: system>> • Example 2: To traverse back from system object to the prompt: Input: racadm/system> cd.. Output: • • racadm>> clearasrscreen Table 9. Details of clearasrscreen Description Clears the last crash (ASR) screen that is in memory.
Output A message is displayed indicating that the pending state is cleared or deleted. Example racadm clearpending NIC.Integrated.1-1 closessn Table 11. Details of closessn attribute Description Closes a communication session on the device. Use getssninfo to view a list of sessions that can be closed using this command. To run this subcommand, you must have the Administrator permission. NOTE: This subcommand ends all the sessions other than the current session.
Example • racadm clrsel The SEL was cleared successfully • racadm clrsel -m server-1 Clear SEL log on server 1 config Table 13. Details of config attribute Description Allows you to set iDRAC configuration parameters individually or to batch them as part of a configuration file and then modify iDRAC configuration properties. If the data is different, the iDRAC object is written with a new value. NOTE: This subcommand will be deprecated in the later versions.
• • Output Examples -i — The -i , or index option, is valid only for indexed groups and can be used to specify a unique group (used with -g and -o). The is a decimal integer from 1 through n, where n can vary from 1 to maximum number of indexes a particular group supports. If -i is not specified, a value of 1 is assumed for groups, which are tables that have multiple entries. The index is specified by the index value, not a named value. 'nx' is allowed for servers.
coredumpdelete Table 15. Details of coredumpdelete Description Deletes any currently available coredump data stored in the RAC. To use this subcommand, you must have Execute Debug Command permission. To use this subcommand, you must have Clear Logs or Execute DebugCommands permission. NOTE: If a coredumpdelete command is issued and a coredump is not currently stored in the RAC, the command displays a success message. This behavior is expected.
• • -s — Specifies the start time for the scheduled job in yyyymmddhhmmss format. The default value TIME_NOW starts the job immediately. -e — Specifies the expiry time for the scheduled job in yyyymmddhhmmss format. The default value TIME_NA does not apply the waiting time. NOTE: For the diagnostic report run operation, the time difference between the -s and -e options must be more than five minutes. Output Provides the Job ID for the diagnostic operation.
• • • Critical Warning Info Valid examples of alert queries are: Input • • • • • idrac.alert.all idrac.alert.audit idrac.alert.audit.lic idrac.alert.audit.warning idrac.alert.audit.lic.critical • • • • • get — Displays the list of eventfilter settings. set — Configures the actions and notifications for a given eventfilter configuration. -i — Message ID for which the simulation is needed. -c — Alert category of the specific event filter. -a — The action that must be invoked when the event occurs.
• Configure using subcategory and severity as parameters. For example, all information events under the licensing subcategory in the audit category are assigned power off as action and all notifications are disabled: racadm eventfilters set -c idrac.alert.audit.lic.info -a poweroff -n none • Configure the event generation interval for temperature statistics: racadm eventfilters set -c idrac.alert.system.tmps.
• • • • Check the firmware update process status. Update iDRAC firmware from FTP or TFTP server by providing an IP address and optional path. Update iDRAC firmware from the local file system using Local and Remote RACADM. Roll back to the standby firmware. Allows you to update the firmware on the KVM, active CMC, standby CMC, iDRAC or an IOM infrastructure device. You can: • • • • Check the firmware update process status. Update CMC from FTP or TFTP server by providing an IP address and optional path.
For SSH or Telnet or Serial: racadm fwupdate -g -u -a -d [-m ] racadm fwupdate -f -d [-m ] racadm fwupdate -u -m iominf- racadm fwupdate -s [-m ] racadm fwupdate -c [-m ] For Remote RACADM: racadm fwupdate -p -u -d [-m ] racadm fwupdate -g -u -a 192.168.0.10 -d firmimg.cmc -m cmc-active racadm fwupdate -r [-m ] racadm -r 192.168.0.
• • -g — Downloads the firmware update using the TFTP server. -a — The IP Address option specifies the TFTP server IP address, used with -g option. Specifies the TFTP server IP address or FQDN used for the firmware image (used with -g). • -p — The -p, or put, option is used to update the firmware file from the managed system to iDRAC. The -u option must be used with the -p option.
• Upload the firmware image from the FTP server and start the firmware update. • racadm fwupdate -f 192.168.0.100 fred xxx -d firmimg.cmc -m cmc-active Upload a firmware image from the client and start firmware update. • racadm fwupdate -p -u -d firmimg.cmc Start IOM infrastructure firmware update. • racadm fwupdate -u -m iominf-1 Update firmware on both the CMCs. • racadm fwupdate -g -u -a 192.168.0.2 -d firmimg.cmc -m cmc-active -m cmcstandby Update firmware on multiple servers.
NOTE: These commands specifically apply to an active-CMC update. Signed CMC Firmware Image: • To get the firmware update status: racadm fwupdate –s –m cmc-active Invalid firmware: The uploaded firmware image does not contain a verification signature. Table 21.
NOTE: INI file format is deprecated. It is recommended to use XML or JSON formats. • Server Configuration Profile XML/JSON format — XML/JSON format files can be exported to a local file, to an NFS network share or to a CIFS network share. NOTE: To run theGet sub-command for Server Configuration Profile XML files, use the Lifecycle Controller version 1.1 or later. NOTE: Some objects may have a pending value if a Set operation is performed on the object through a reboot job.
• • -l—Specifies network share location to which the file will be exported. -t—Specifies the file type to be exported. The valid values are: • • • • • • • JSON—It exports the SCP JSON file to a network share file. xml—It exports the SCP xml format file, either to a local or network share file. ini—It exports the legacy configuration file. If -t is not specified, then the ini format file is exported. It can only be exported to a local file.
• Export the xml configuration of the iDRAC component to a CIFS share. racadm get -f file -t xml -u myuser -p xxx -l //192.168.0/share iDRAC.Embedded.1 • -c Include password hash in the configuration .xml file. racadm get -f -t xml -l -u p -t xml --includeph getconfig Table 24. Details of getconfig attribute Description Retrieves iDRAC configuration parameters individually or all iDRAC configuration groups may be retrieved and saved to a file.
• • • Output -o — The -o or object option specifies the object name that is used in the query. This option is optional and can be used with the -g option. -u — The-u or user name option, is used to display the configuration for the specified user. The option is the login name for the user. -v — The -v option displays more information with the display of the properties and is used with the -g option.
• Displays the user group instance at index 2 with verbose information for the property values. racadm getconfig -g cfgUserAdmin -i 2 -v • Displays an entire group of serial configuration. racadm getconfig -g cfgSerial • Displays a single object from a particular group. racadm getconfig -g cfgSerial -o cfgSerialBaudRate • Displays an indexed group. racadm getconfig -g cfgUserAdmin -o cfgUserAdminUserName -i 2 • Displays the current Enhanced Cooling Mode property configuration.
DHCP DHCPServerV4 MAC Address FQDD IPv4 Address Subnet Mask IPv6 Address Prefix Length IPv4 Gateway Address IPv4 DNSServer Address IPv4 DNSServer Address : : : : : : : : : 0: 1: Enabled 10.94.224.25 14-FE-B5-FF-B1-9C NIC.Integrated.1-1-1 10.94.225.189 255.255.255.128 fe80::7c5f:a114:84d4:17f6 64 10.94.225.129 10.116.2.250 10.116.2.251 getled Table 27. Details of getled attribute Description Displays the LED settings on a module: blinking, not blinking, or unknown (for empty slots).
getniccfg Table 28. Details of getniccfg attribute Description Displays the current and static NIC settings for iDRAC. Displays the current NIC settings. Synopsis Input racadm getniccfg [-m ] –m must be one of the following values: • • • • Output chassis : Default state if -m is not specified. server- : where n=1–16 server- : where n=1–8; x = a, b, c, d (lower case) switch- : where n=1–6 NOTE: Table 29.
IP Address 14 =:: IP Address 15 =:: LOM Status: NIC Selection =dedicated Link Detected =Yes Speed =1Gb/s Duplex Mode =Full Duplex Active NIC =Dedicated Static IPv4 settings: Static IP Address =192.168.0.120 Static Subnet Mask =255.255.255.0 Static Gateway =192.168.0.1 Static IPv6 settings: Static IP Address 1 =2000:de11:bcd1:fc14:1234:5678:2468:abcd/64 Static Prefix Length =64 Static Gateway =:: IPv6 information is displayed only if IPv6 is enabled in iDRAC.
NOTE: On Local RACADM, the number of logs are restricted to 100 by default. • • --more — Displays one screen at a time and prompts you to continue (similar to the UNIX more command). -s — Specifies the starting record used for the display. • -c — Specifies the number of records to display. NOTE: On Remote RACADM, the number of logs are restricted to 25 by default. • • • -i — Displays the number of entries in the CMC log.
Category AgentID Severity Timestamp Message Arg Message Arg Message Example = = = = 1 = 2 = = Audit CMC Information 2014-10-18 15:48:10 14503 48186 Successfully closed Session process: pid=14503 sid=4818 Display the recent 2 records for RAC log racadm getraclog -c 2 SeqNumber = 4102 Message ID = LIC201 Category = Audit AgentID = DE Severity = Warning Timestamp = 2014-06-12 01:38:19 Message = License yPMRJGuEf7z5HG8LO7gh assigned to device iDRAC expires in 4 days.
getremoteservicesstatus Table 32. Details of getremoteservicesstatus Description Displays the status of a system.
Example • Display entire log. racadm getsel • Display number of records in log. racadm getsel -i getsensorinfo Table 34. Details of getsensorinfo Description Displays the status for system sensors. NOTE: For Dell PowerEdge FX2 chassis with FM120x4 server, the power related information is not displayed. NOTE: General purpose graphical processing unit (GPGPU) status is displayed only on PowerEdge C4130 servers.
System Board Fan3 RPM Ok 5880 RPM 600 RPM NA 0% System Board Fan4 RPM Ok 5880 RPM 600 RPM NA 0% System Board Fan5 RPM Ok 5640 RPM 600 RPM NA 144% System Board Fan6 RPM Ok 5880 RPM 600 RPM NA 152% Table 39. Voltage sensor CPU1 VCORE PG Ok Good NA NA System Board 3.3V PG Ok Good NA NA System Board 5V AUX PG Ok Good NA NA CPU1 M23 VPP PG Ok Good NA NA System Board 1.
System Board Pwr Consumption Ok 56 Watts NA 1386 Watts 0 Watts [N] Table 41. PROCESSOR sensor CPU1 Status Ok Presence Detected NA NA CPU2 Status N/A Absent NA NA Table 42.
4 4 4 4 4 4 23:09:40 23:09:40 23:09:40 23:09:40 23:09:40 23:09:40 idrac8 idrac8 idrac8 idrac8 idrac8 idrac8 L4, L4, L4, L4, L4, L4, S3 S3 S3 S3 S3 S3 [10297]: [10297]: [10297]: [10297]: [10297]: [10297]: ret is 0 probename is Chassis Controller pCMCStatusobj->offsetKey is 24 pCMCStatusobj->sensorValue is 0 MAP Uninitialized, time to uninit = 0 millisec RACADM total execution time: 1680 milliseconds Table 44.
NOTE: Based on the Session ID (SSNID) or the user name (User), the iDRACCMC administrator can close the respective sessions or all the sessions using the closessn subcommand. For more information, see closessn. Synopsis racadm getssninfo [-u ] [-A] racadm getssninfo [-u | -u *] [-A] Input • • -u — displays only sessions associated with a specific user. -A — does not display headers or labels. Table 50. Example SSNID Type User IP Address Login Date/Time 58999 SSH root 192.
NOTE: The host name and OS Name fields in the getsysinfo output display accurate information only if the Dell OpenManage Server Administrator is installed on the managed system. Else, these fields may be blank or inaccurate. An exception to this are VMware operating system names, which are displayed even if the Server Administrator is not installed on the managed system.
Chassis Midplane Version= 1.1 Power Status = ON Output RAC Information: RAC Date/Time = Thu Sep Firmware Version Firmware Build Last Firmware Update Hardware Version MAC Address = = = = = 2.20.20.20 41 09/02/2015 22:18:35 0.01 B8:2A:72:FC:4F:B0 Common settings: Register DNS RAC Name DNS RAC Name Current DNS Domain Domain Name from DHCP = = = = 1 ipmierrata sha512.
• Display iDRACCMC information racadm getsysinfo -d • Display IPv4 details without header racadm getsysinfo -A "RAC IPv4 Information:" "1" "10.94.195.33" "10.94.195.1" "255.255.255.0" "1" "10.94.192.67" "0.0.0.0" "1" "CMC IPv4 Information:" "1" "192.168.0.10" "192.168.0.10" "255.255.255.0" "1" "192.168.0.10" "0.0.0.0" "1" gettracelog Table 53. Details of attribute Description Lists all the trace login entries of iDRAC. Displays the CMC diagnostic trace log.
getversion Table 54. Details of getversion attribute Description Displays the current software version, model and generation information, and whether the target device can be updated. NOTE: The Linux shell script does not support the characters—$ (dollar),` (back quote), \ (forward slash), & (ampersand), ( (open bracket), ) (Close bracket), = (equal), | (Pipe), ; (semi colon)," (Double quote), ' (single quote), < (less than), and > (greater than).
server-7 1.0.6 PowerEdgeM620 server-9 1.0.5 PowerEdgeM520 racadm getversion Bios Version = 2.0.18 iDRAC Version = 2.00.00.00 Lifecycle Controller Version = 2.00.00.00 Table 57. Details server-1 1.6.0 PowerEdgeM520 server-2 6.3.0 PowerEdgeM610x server-4 7.0.0 PowerEdgeM710HD server-5 6.3.0 PowerEdgeM710 server-7 1.7.1 PowerEdgeM620 server-9 1.7.1 PowerEdgeM520 Table 58.
hwinventory Table 59. Details of hwinventory Description Allows you to display or export current internal hardware inventory or shipped hardware inventory by device. NOTE: iDRAC supports a maximum of 12 parallel sessions of hardware inventory. Synopsis • • • • racadm racadm racadm racadm or NFS Input • — Specifies the FQDD of the target device. • • • • hwinventory hwinventory NIC|FC hwinventory hwinventory export -f -u -p -l • FQDD — NIC.
PCI Sub Vendor ID: PCI Device ID: PCI Sub Device ID: Current MAC Address: Permanent MAC Address: Virtual iSCSI MAC Address: Permanent iSCSI MAC Address: Virtual FIP MAC Address: Permanent FIP MAC Address: Permanent FCoE MAC Address: Slot Type: Data Bus Width: Slot Length: Bus Number: DeviceNumber: Function Number: Last Update Time: Last System Inventory Time: ProductName: WWN: VirtWWN: WWPN: VirtWWPN: Family Version: Controller BIOS Version: EFI Version: Max Bandwidth: Min Bandwidth: FCoE WWNN: Vendor Name:
Priority Flow Control: DCB Exchange Protocol: Congestion Notification: VEB-VEPA Single Channel: VEB-VEPA Multi Channel: EVB: BPE: Open Flow: Partition WOL Support: Virtual Link Control Partition RX Flow Control: Partition TX Flow Control: TX Bandwidth Control Maximum: TX Bandwidth Control Minimum: • Not Not Not Not Not Not Not Not Not Not Not Not Not Not Capable Capable Capable Capable Capable Capable Capable Capable Capable Capable Capable Capable Capable Capable To export the inventory to a remote CIFS
PCI Sub Device ID: PCI Bus: PCI Device: PCI Function: Vendor Name: Device Name: 2001000E1E091075 WWN: VirtWWN: WWPN: VirtWWPN: Chip Type: Family Version: EFI Version: OS Driver Version: First FC Target WWPN: First FC Target LUN: Second FC Target WWPN: Second FC Target LUN: Hard Zone Address: Hard Zone Enable: FC Tape Enable: Loop reset Delay: Frame Payload Size : Fabric Login Retry Count: Fabric Login Timeout: Port Login Retry Count: Port Login Timeout: Port Down Retry Count: Port Down Timeout: Link Down Ti
collisions:0 txqueuelen:1000 RX bytes:272532097 (259.9 MiB) TX bytes:0 (0.0 B) inlettemphistory Table 62. Details of inlettemphistory Description Displays the average and the peak temperatures during the last hour, day, week, month, or year. Also Exports the inlet temperature history data file. The file can be exported to a remote file share, local file system, or the management station. NOTE: For FM120x4 systems, this subcommand provides the historical data for system board temperature.
Peak Last Last Last Last Last Temperatures Hour = 23C ( Day = 25C ( Week = 27C ( Month = 29C ( Year = 29C ( 73.4F 77.0F 80.6F 84.2F 84.2F ) ) ) ) ) [At [At [At [At [At Wed, Tue, Fri, Wed, Wed, 30 29 25 16 16 May May May May May 2012 2012 2012 2012 2012 11:00:57] 15:37:23] 10:38:20] 15:34:13] 15:34:13] jobqueue Table 63. Details of jobqueue Description Enables you to view and delete a job or jobs in the current Job Queue. NOTE: • To run this subcommand, you must have the Server control privilege.
Example • View jobs in the current job queue. racadm jobqueue view • View status of a specific job ID. racadm jobqueue view -i • Issue configuration changes for a PERC controller then start a real time job to execute the changes. racadm set RAID.Slot.3-1.RAIDdefaultWritePolicy WriteBack racadm set RAID.Slot.3-1.Name “Prod Workload” racadm jobqueue create RAID.Slot.3-1 –realtime • Delete all possible jobs from the current job queue.
lclog Table 65. Details of lclog Description Allows you to: • • • • • Export the lifecycle log history. The log exports to remote or local share location. View the lifecycle log for a particular device or category. Add comment to a record in lifecycle log. Add a work note (an entry) in the lifecycle log. View the status of a configuration job. NOTE: • • Synopsis When you run this command on Local RACADM, the data is available to RACADM as a USB partition and may display a pop-up message.
• • • • • • • • • • • • • • Storage • Worknotes • Config • Updates • Audit -b —The subcategory used to filter the records. Provides multiple subcategories using a "," as the delimiter. -q—The sequence number from which the records must be displayed. Records older than this sequence number is displayed. NOTE: This parameter input is an integer. If an alphanumeric input is provided, then invalid subcommand syntax error is displayed. -n—Specifies the n number of records that must be displayed.
• Display the records under storage and system categories with severities set to warning or critical. racadm lclog view -c storage,system -s warning,critical • Display the records having severities set to warning or critical, starting from sequence number 4. racadm lclog view -s warning,critical -q 4 • Display 5 records starting from sequence number 20. racadm lclog view -q 20 -n 5 • Display all records of events that have occurred between 2011-01-02 23:33:40 and 2011-01-03 00:32:15.
Synopsis Input • racadm license view [-c ] • racadm license import [-f ] -l -u -p -c [-o] • racadm license export -f [-l ] [-u ] [-p ] -e -c • racadm license delete -t [-o] • racadm license delete -e [-o] • racadm license delete -c [-o] • racadm license replace -u -p -f l
• Import a license from a CIFS share to a device, in this case Embedded iDRAC. racadm license import -u admin -p xxx -f License.xml -l //192.168.0/licshare -c idrac.embedded.1 • Import a license from an NFS share to a device, in this case Embedded iDRAC. racadm license import -f Licen.xml -l 192.168.0:/share -c idrac.embedded.1 • Import a license by overriding the EULA warning. racadm license import -u admin -p passwd -f License.xml -l //192.168.0/licshare -c idrac.embedded.
netstat Table 67. Details of netstat Description Display the routing table and network statistics. Synopsis racadm netstat Examples • To display the routing table and network statistics, type the following command: $ racadm netstat nicstatistics Table 68. Details of nicstatistics Description Synopsis Displays the statistics for the NIC FQDD. • racadm nicstatistics • racadm nicstatistics • racadm hwinventory NIC.Integrated.
Total Unicast Bytes Transmitted: • 0 To get the network statistics, type the following command: $ racadm nicstatistics NIC.Slot.5-2-1 : QLogic CNA Gigabit Ethernet-B8:AC:6F:B3:BF:10 NIC.Slot.5-2-1 : QLogic CNA Gigabit Ethernet-B8:AC:6F:B3:BF:11 NIC.Slot.5-2-1 : QLogic CNA Gigabit Ethernet-B8:AC:6F:B3:BF:12 NIC.Slot.5-2-1 : QLogic CNA Gigabit Ethernet-B8:AC:6F:B3:BF:13 NIC.Slot.5-2-1 : QLogic CNA Gigabit Ethernet-B8:AC:6F:B3:BF:14 ping Table 69.
Example Pinging 2011:de11:bdc:194::31 from 2011:de11:bdc:194::101 with 32 bytes of data: Reply from 2011:de11:bdc:194::31: time<1ms Reply from 2011:de11:bdc:194::31: time<1ms Reply from 2011:de11:bdc:194::31: time<1ms Reply from 2011:de11:bdc:194::31: time<1ms Ping statistics for 2011:de11:bdc:194::31: Packets: Sent = 4, Received = 4, Lost = 0 (0% loss), Approximate round trip times in milli-seconds: Minimum = 0ms, Maximum = 0ms, Average = 0ms RACADM Proxy Table 71.
User Configuration Administrator Configure User Clear Logs Administrator Logs • • • Chassis Control Administrator System Control Server Administrator System Control Test Alert User System Operations Debug Command Administrator Debug Fabric x Administrator (where x is A, B, or C) System Control The user privilege in the Remote RACADM proxy for CMC maps to iDRAC privilege. When CMC is not placed on the network, the import, export, and file operation commands to CIFS, NFS, or FTP will fail.
To run this subcommand, you must have the Administrator privilege. To run this subcommand, you must have the Debug permission.
Current IP Address Current IP Gateway Current IP Netmask DHCP Enabled Current DNS Server 1 Current DNS Server 2 DNS Servers from DHCP = = = = = = = 192.168.0.1 192.168.0.1 192.168.0.1 0 0.0.0.0 0.0.0.
ff00::/8 256 0 :: 0 eth1 Kernel IP routing table Destination Gateway 0.0.0.0 192.168.0.1 192.168.0.1 0.0.0.0 Genmask 0.0.0.0 192.168.0.1 Active Internet connections (w/o servers) Proto Recv-Q Send-Q Local Address tcp 0 0 192.168.0.1:53986 tcp 0 0 192.168.0.1:53985 tcp 0 0 192.168.0.1:199 tcp 0 0 192.168.0.1:199 U Flags UG U MSS Window 0 0 0 0 Foreign Address 192.168.0.1:199 192.168.0.1:199 192.168.0.1:53986 192.168.0.
Current DNS Server 2 DNS Servers from DHCP Register DNS CMC Name DNS CMC Name Current DNS Domain = = = = = 0.0.0.
NOTE: After you run the racreset subcommand, CMC may require up to two minutes to return to a usable state. NOTE: There is a 100 percent fan request when the command is run against the servers. Synopsis racadm racreset soft racadm racreset hard racadm racreset soft -f racadm recreset hard -f racadm racreset [-m [-f]] Input • -f — This option is used to force the reset.
NOTE: Certain firmware processes must be stopped and restarted to complete the reset to defaults. iDRAC becomes unresponsive for about 30 seconds while this operation completes. Synopsis • RAC reset operation initiated successfully. It may take several minutes for the RAC to come online again. racadm racresetcfg Input Example • racadm racresetcfg -f • racadm racresetcfg -all • • -f — Force resetcfg. If any vFlash partition creation or formatting is in progress, iDRAC returns a warning message.
• NOTE: Use a forward slash (/) when providing the image location. If backward slash (\) is used, override the backward slash for the command to run successfully. For example: racadm remoteimage -c -u user -p xxx -l /\/\192.168.0.2/\CommonShare/ \diskette NOTE: The following options only apply to connect and deploy actions • -u —Username User name to access the network share. For domain users, you can use the following formats: Example • • • • -p domain/user domain\user user@domain —Password to access
Synopsis racadm rollback [--reboot] NOTE: To get the list of available rollback versions and FQDDs, run the racadm swinventory command. Input • • : Specify the FQDD of the device for which the rollback is required. --reboot: Performs a graceful system reboot after the BIOS firmware rollback. Example • To perform BIOS firmware rollback: racadm rollback iDRAC.Embedded.1-1 RAC1056: Rollback operation initiated successfully.
• Input racadm serveraction -m • -m — Must be one of the following values: • • server–: where n=1–16 • server–: where n=1–8; x=a–d (enter lowercase letter only). -a — Performs power action on all servers. Not allowed with the powerstatus action. — Specifies the power management operation to perform. The options are: • • hardreset — Performs a force reset (reboot) operation on the managed system.
• Get Power Status of blade 16 on CMC by using the following command: racadm serveraction -m server-16 powerstatus ON • Turn off the server 16 from CMC, when the power is already turned off on that server by using the following command: racadm serveraction -m server-16 powerdown Server is already powered OFF. • Power action on all servers by using the following command: racadm serveraction -a powerup set Table 80. Details of set Description Modifies the value of configuration objects on a component.
• racadm get ..
If -b is not specified, graceful shutdown is taken as the default except as noted above for files containing new values for immediate application-capable s. NOTE: If the operating system is in use, then the graceful shutdown option may time out within 300 seconds. If this operation is unsuccessful, then retry with the force option. • • • -w — Maximum time to wait for the graceful shutdown to occur. The value must be entered in seconds.
• racadm set -f myidrac.xml -t xml -l 10.1.2.3:/myshare Configure a RAC from an XML configuration file located on a remote HTTP share. • racadm set -f myfile.xml -t xml -u httpuser -p httppwd -l http://test.com/myshare Configure a RAC from an XML configuration file located on a remote HTTPS share. • racadm set -f myfile.xml -t xml -u httpsuser -p httpspwd -l https://test.com/myshare Import a Server Configuration Profile from a CIFS share, using only the iDRAC component.
• -l — Specifies the LED state. The values are: • • Example • 0 — No Blinking 1 — Blinking racadm setled -m chassis -l 1 Sets LED state on Chassis to Blink • racadm setled -m server-1 -1 1 LED state was set successfully. • racadm setled -m server-9 -1 1 ERROR: Server in slot 9 is an extension of the server in slot 1. NOTE: The setled command generates an error when run on the extension slot of a multi-slot server. • From iDRAC stop LED from blinking.
Input • racadm setniccfg [-m chassis] -o • racadm setniccfg –p [-6] • racadm setniccfg [-m ] -k [ ] • racadm setniccfg [-i ] -v [ ] • • • -d — Enables DHCP for the NIC. It is enabled by default. -d6 — Enables AutoConfig for the NIC (default is disabled). -s — Enables static IP settings. The IPv4 address, netmask, and gateway must be specified. Otherwise, the existing static settings are used.
• Configuration of VLAN id and priority of a slot or all blades in a sleeve. racadm setniccfg -i 5 -v 1000 • 7 Configuration of CMC to a static IPv6 address. racadm setniccfg -m chassis -s -6 2001:DB8::2 64 2001:DB8::1 • Configuration of server to use stateless autoconfiguration address. racadm setniccfg -m server-1 -d -6 • Configuration of VLAN id and priority for a switch. racadm setniccfg -m switch-1 -v 1000 7 • Removal of VLAN configuration from a switch.
• Upload an invalid key to iDRAC User 2 in the first key space using a string. $ racadm sshpkauth -i 2 -k 1 -t "This is invalid key Text" ERROR: Key text appears to be corrupt • Upload a valid key to iDRAC User 2 in the first key space using a file. $ racadm sshpkauth -i 2 -k 1 -f pkkey.key Key file successfully uploaded. • Get all keys for User 2 on iDRAC.
• Download Active Directory certificate: racadm -r 192.168.0 -u root -p xxx sslcertdownload -t 2 -f ad_cert.txt NOTE: This command is not supported in the firmware RACADM interface as it is not a file system. sslcertupload Table 85. Details of sslcertupload attribute Description Uploads a custom SSL server or CA certificate for Directory Service from the client to iDRAC. To run this subcommand, you must have the Server Control privilege.
• • 1=server certificate • 2=Active Directory -A — Prevents printing headers or labels. NOTE: If a certificate is generated using comma ‘,’ as one of the parameters for the Organization Name, Common Name, Location Name, or State Name, then this command displays the partial name in the respective fields only up to the comma. The rest of the string is not displayed. NOTE: For self-signed certificate, the common name includes PQDN (Partially qualified domain name) or FQDN (Fully qualified domain name).
Valid To Jun 4 23:54:19 2021 GMT racadm sslcertview -t 1 -A 00 US Texas Round Rock Dell Inc. Remote Access Group iDRACCMC default certificate US Texas Round Rock Dell Inc. Remote Access Group iDRACCMC default certificate Jun 7 23:54:19 2011 GMT Jun 4 23:54:19 2021 GMT sslcertdelete Table 88. Details of sslcertdelete Description Command to delete a custom signing certificate from iDRAC. To run this subcommand, you must have the Server Control privilege.
Example Use Remote RACADM to delete the custom signing certificate. $ racadm -r 192.168.0 -u root -p xxx sslcertdelete -t 3 sslcsrgen Table 89. Details of sslcsrgen attribute Description Generates and downloads a certificate signing request (CSR) file to the client’s local file system. The CSR can be used for creating a custom SSL certificate that can be used for SSL transactions on iDRACCMC. To run this subcommand, you must have the Configure iDRACchassis administrator privilege.
NOTE: The duration for generating a CSR key depends on the length specified for the key. sslkeyupload Table 90. Details of sslkeyupload Description Uploads SSL key from the client to iDRAC. To run this subcommand, you must have the Server Control privilege. NOTE: This option is only supported on the remote interface (s). Synopsis Input Output Example racadm sslkeyupload -t -f • -t — Specifies the key to upload. The value is: • • 1 — SSL key used to generate the server certificate.
• To view the help details for get command, run the following command: racadm storage help get • To generate and view information about the inventory of storage root node, run the following command: racadm storage get status • To generate and view information about the inventory of controllers, run the following command: racadm storage get controllers -o racadm storage get controllers -o -p • To get the list of controllers, run the following command: racadm storage
• To generate and view information about the inventory of enclosures, run the following command: racadm storage get enclosures -o racadm storage get enclosures --refkey racadm storage get enclosures --refkey -o p • To get the list of enclosures, run the following command: racadm storage get enclosures • To get the properties of the PCIeSSD enclosure, run the following command: racadm storage ge
• To generate and view information about the inventory of fans, run the following command: racadm storage get fans --refkey racadm storage get fans --refkey -o racadm storage get fans --refkey -o p • To generate and view information about the inventory of EMMs, run the following command: racadm storage get emms -refkey rac
• To create, delete, and secure the virtual disks. To start or stop the consistency check on the specified virtual disk, run the following command: racadm storage createvd: -rl {r0|r1|r5|r6|r10|r50|r60}[-wp {wt|wb| wbf}] [-rp {nra|ra|ara}] [-ss {1k|2k|4k| 8k|16k|32k|64k|128k|256k|512k|1M|2M|4M|8M| 16M}]-pdkey: [dcp {enabled|disabled|default}] [-name ] [-size {b|k|m|g|t}] [T10PIEnable] NOTE: T10PI is not supported on PERC 9 and PERC 10.
NOTE: Convert to RAID and non-RAID is not supported on PERC 10 and BOSS controllers.
• To start or stop a blink or identify operation on the specified or PCIeSSD device, run the following command: racadm storage blink: racadm storage blink: racadm storage unblink: racadm storage unblink: • NOTE: The Start or Stop a Blink feature is not supported for HHHL PCIe SSD devices.
• • • -name —Specifies the name of the virtual disk. -size —Specifies the size of each virtual disk. • b—Specifies the size in bytes • k—Specifies the size in kilobytes • m—Specifies the size in megabytes • g—Specifies the size in gigabytes • t—Specifies the size in terabytes -sc—Number of spans in a virtual disk (required for multi-span RAID level). NOTE: • For PERC9, if the value of controller.
NOTE: Ensure that ISM is installed and running to perform the preparetoremove operation. • secureerase—Specifies the PCIeSSD drive to perform the secure erase operation. Example Inventory • To view the help details for get command, run the following command: racadm>>storage help get racadm storage help get Storage monitoring and inventory of hardware RAID connected to the system.
This command retrieves the status of the inventory for storage root node. racadm storage get status raid Root Node Status : Ok • To generate and view information about the inventory of controllers connected to the server. racadm storage get controllers RAID.Integrated.1-1 The following command is an optimized version and displays the full controller objects along with their keys: racadm storage get controllers -o RAID.Integrated.
• This operation displays vdisk, which has pending operation: racadm storage get vdisks -pending DISK.Virtual.267386880:RAID.Slot.5-1 • This operation displays controllers, which have pending operations: racadm storage get controllers -pending RAID.Integrated.1-1 • This operation displays pdisk, which has pending operation: racadm storage get pdisks -pending Disk.Bay.20:Enclosure.Internal.0-1:RAID.Integrated.
EncryptionMode SasAddress PciDeviceId PciSubdeviceId PciVendorId PciSubvendorId PciBus PciDevice PciFunction BusWidth SlotLength SlotType MaxCapableSpeed LearnMode T10PICapability SupportRAID10UnevenSpans SupportEnhancedAutoForeignImport EnhancedAutoImportForeignConfig SupportControllerBootMode ControllerBootMode RealtimeConfigurationCapability CurrentControllerMode BootVD = = = = = = = = = = = = = = = = = = = = = = = None 0x5B083FE0E3EF5A00 0x5d 0x1f4d 0x1000 0x1028 0x7 0x0 0x0 8x or x8 Other PCI Express
CurrentControllerMode BootVD • = Not Supported = Disk.Virtual.0:RAID.Integrated.1-1 To generate and view information about the inventory of batteries connected to the controller, run the following command: racadm storage get batteries The following command is an optimized version and displays the batteries along with their keys: racadm storage get batteries -o Battery.Integrated.1:RAID.Integrated.
• 132 OperationalState Not applicable Layout Raid-0 Size 278.88 GB SpanDepth 1 AvailableProtocols SAS MediaType HDD ReadPolicy Read Ahead WritePolicy Write Back StripeSize 64K DiskCachePolicy Default BadBlocksFound NO Secured NO RemainingRedundancy 0 EnhancedCache Not Applicable T10PIStatus Disabled BlockSizeInBytes 512 Table 94.
The following command displays all enclosure keys connected to the connectors: racadm storage get enclosures --refkey RAID.Integrated.1-1 Enclosure.Internal.0-1:RAID.Integrated.1-1 The following command is an optimized and filtered version: racadm storage get enclosures --refkey RAID.Integrated.1-1 -o -p Name Enclosure.Internal.0-1:RAID.Integrated.
Disk.Bay.0:Enclosure.Internal.0-1:RAID.Integrated.1-1 Status = Ok DeviceDescription = Disk 0 in Backplane 1 of Integrated raid Controller 1 RollupStatus = Ok Name = Physical Disk 0:1:0 State = Online OperationState = Not Applicable PowerStatus = Spun-Up Size = 278.88 GB FailurePredicted = NO RemainingRatedWriteEndurance = Not Applicable SecurityStatus = Not Capable BusProtocol = SAS MediaType = HDD UsedraidDiskSpace = 278.88 GB AvailableraidDiskSpace = 0.
The following command is an optimized and filtered version: racadm storage get emms --refkey -o -p • To generate and view information about the inventory of PSU connected to the enclosure.
PCIeNegotiatedLinkWidth = x4 PCIeCapableLinkWidth = x4 MaxCapableSpeed = 8 GT/s NegotiatedSpeed = 8 GT/s FormFactor = 2.5 Inch Revision = IPM0ED35SAM SAMSUNG MZWEI800HAGM 000D3 RemainingRatedWriteEndurance = 100 % FailurePredicted = NO To get the list of controllers and properties of the PCIeSSD controller. The following command provides the list of controllers: racadm storage get controllers RAID.Integrated.1-1 PCIeExtender.Slot.
- The default value is one for basic RAID levels. - If RAID10 Uneven Span is Supported then for RAID10: -sc option will be optional. Will allow only 0 value for this option. -T10PIEnable : To create a VD with PI -------------------------------------------------------------------------------Description : Create a VD. -------------------------------------------------------------------------------Examples : racadm storage createvd:RAID.Integrated.1-1 -rl r0 pdkey:Disk.Bay.0:Enclosure.Internal.0-0:RAID.
• The following command imports the current foreign configuration from the controller: racadm storage importconfig:RAID.Integrated.1-1 • The following command deletes all virtual disks and un-assign hot spare from the associated controller: racadm storage resetconfig:RAID.Integrated.1-1 • The following command clears the current foreign configuration from the controller: racadm storage clearconfig:RAID.Integrated.1-1 NOTE: After a resetconfig or clearconfig operation, the data cannot be reversed.
• To unlock storage racadm storage unlock:RAID.Integrated.1-1 -key 1234 -passwd Dell@333 swinventory Table 95. Details of swinventory Description Displays the list of software objects and associated properties installed on a server. NOTE: Lifecycle Controller and CSIOR may not be enabled to run this subcommand. Synopsis racadm swinventory Input racadm swinventory Output racadm swinventory ------------------SOFTWARE INVENTORY------------------ComponentType = FIRMWARE ElementName = Power Supply.Slot.
• • Synopsis The minimum Lifecycle Controller version 1.3 is required. The minimum Lifecycle Controller version 2 1.3 is required. • racadm systemconfig backup -f [-n passphrase] [-l -u -p ] [--vFlash] • racadm systemconfig restore -f [-n passphrase ] [-nopreserve] [-l -u -p ] [--vFlash] • To create an AutoBackup Schedule.
• • If the-wom option is specified, then the valid values for -rp are 1–52 • If the-dow option is specified, then the valid values for -rp are 1–366. -mb: Specifies the maximum backup parameter. For --vflash maximum backup is 1. NOTE: • Avoid using the -l, -u, and -p options with --vFlash option. • If a backup file is created in a subfolder within the CIFS shared folder, then the subfolder name must be mentioned in the filename option.
Synopsis • To erase a specific component. racadm systemerase • To erase multiple components.
• To list the usage statistics of a specific sensor racadm systemperfstatistics iDRAC.Embedded.
• To export the collected report data to local share. racadm techsupreport export -f Input • -t — type of logs. You can specify any of the following values separated by a ‘,’ (comma) • • • • SysInfo — System Information OSAppNoPII — Filtered OS and Application data OSAppAll — OS and Application data TTYLog — TTYLog data NOTE: • • • • • For updating the operating system application data collection, enter the value OSAppNoPII or OSAppAll to the -t option.
Input -i — Specifies the index of the email alert to test. Output Success: Test e-mail sent successfully Failure: Unable to send test e-mail Example Commands for the idrac.EmailAlert group: • Enable the alert. racadm set idrac.EmailAlert.1.Enable 1 • Set the destination email address. racadm set idrac.EmailAlert.1.Address user1@mycompany.com • Set the custom message that is sent to the destination email address. racadm set idrac.emailalert.1.
• View the current test trap settings. racadm get iDRAC.SNMP.Alert. where is a number from 1 to 8 • Send a test trap to the destination configured for index 1: racadm testtrap -i 1 testalert Table 102. Details of testalert Description Tests FQDN supported SNMP trap notifications. To run this subcommand, you must have the Test Alert User Access. Synopsis Input racadm testalert -i -i — Specifies the index of the trap test. index must be an integer from 1 to 8 on iDRAC.
traceroute6 Table 104. Details of traceroute6 attribute Description Traces the network path of routers as the packets traverse from the system to a destination IPv6 address. To run this subcommand, you must have the Administrator privilege. To run this subcommand, you must have the Execute Diagnostic Commands permission. Synopsis Input racadm traceroute6 – Specifies IPv6 address.
Synopsis racadm update -f [--reboot] racadm update -f -l -u -p [--reboot] racadm update -f -l [--reboot] racadm update –f -t -l -u -p [-a ] [--verifycatalog] racadm update –f -t -l -u
For devices that perform update process without rebooting the host, the update status changes from Downloading to Completed. For devices that require host reboot to perform update process, the update status changes from Downloading to Scheduled. When the status is displayed as Scheduled, reboot the host to start the update process.
• Generate a comparison report using about the available updates in the repository. racadm update -f Catalog.xml -l 192.168.11.10:/Repo -t NFS -a FALSE -verifycatalog • Perform update from an FTP repository and reboot the server to apply the updates. racadm update -f Catalog.xml -e 192.168.11.10/Repo/MyCatalog -a TRUE -t FTP • Perform update from an FTP repository with authentication and reboot the server to apply the updates. racadm update -f Catalog.xml -e 192.168.11.
Output If upload is successful, the message User certificate successfully uploaded to the RAC. If unsuccessful, appropriate error message is displayed. Example To upload user certificate for user 6. racadm usercertupload -t 1 -f c:\cert\cert.txt -i 6 usercertview Table 107. Details of usercertview Description Displays the user certificate or user CA certificate that exists on iDRAC.
Input • • Output If initialization is in progress, the message Initialization of the vFlash SD Card is now in progress is displayed. If unsuccessful, appropriate error message is displayed. Initialize— performs initialize operation on SD card. Status — indicates to view the progress or status report of the initialize operation. If the status of the last operation performed is successful, the message LastAction Progress Status=============Initialize SD Card 100 % Complete is displayed.
• Create a partition from a remote image. racadm vflashpartition create -i 1 -o Drive1 -e cddvd -t image -l //ipaddress/sharefolder/isoimge.iso -u username -p xxx A new partition is created. By default, the created partition is read-only. This command is case-sensitive for the image filename extension. If the filename extension is in uppercase, for example FOO.ISO instead of FOO.iso, then the command returns a syntax error. NOTE: • This feature is not supported in Local RACADM.
3 iDRAC Property Database Group and Object Descriptions The iDRAC property database contains the configuration information for iDRAC. Associated object is organizing data, and object group is organizing object. The IDs for the groups and objects that the property database supports are listed in this section for iDRAC Enterprise on Blade Servers and iDRAC Enterprise or Express on Rack and Tower Servers. To configure iDRAC, use the group and object IDs with the RACADM subcommands.
• • • • • cfgSensorRedundancy cfgVFlashSD cfgVFlashPartition cfgLogging cfgRacSecurity Displayable Characters Displayable characters include the following set: abcdefghijklmnopqrstuvwxwz ABCDEFGHIJKLMNOPQRSTUVWXYZ 0123456789~`!@#$%^&*()_+-={}[]|\:";'<>,.?/ Table 111.
Subcommand iDRAC on Blade Servers iDRAC on Rack and Tower Servers cfgServerPower Yes Yes cfgServerPowerSupply No Yes cfgIPv6LanNetworking Yes Yes cfgIPv6URL Yes Yes cfgIpmiSerial No Yes cfgSmartCard Yes Yes cfgNetTuning No Yes cfgSensorRedundancy No Yes cfgVFlashSD Yes Yes cfgVFlashPartition Yes Yes cfgLogging Yes Yes cfgRacSecurity Yes Yes cfgIpv6StaticLanNetworking idRacInfo This group contains display parameters to provide information about the specifics of iDRAC b
idRacVersionInfo (Read Only) Table 114. Details of Read only attribute - idRacVersionInfo Description String containing the current product firmware version Legal Values A string of up to 63 ASCII characters. Default The current version number. idRacBuildInfo (Read Only) Table 115. Details of Read only attribute - idRacBuildInfo Description String containing the current RAC firmware build version. Legal Values A string of up to 16 ASCII characters.
# idRacVersionInfo=P21 # idRacBuildInfo=200708301525 # idRacName=CMC-1 racadm getconfig -g idRacInfo # idRacType=16 # idRacProductInfo=Integrated Dell Remote Access Controller # idRacDescriptionInfo=This system component provides a complete set of remote management functions for Dell PowerEdge Servers # idRacVersionInfo=1.06.06 # idRacBuildInfo=15 # idRacName=idrac-GSRS3V1 cfgStaticLanNetworking This group contains parameters to configure the device NIC for IPv4.
Default 192.168.0 cfgNicStaticUseDhcp (Read or Write) Table 121. Details of cfgNicStaticUseDhcp Description Specifies whether DHCP is used to configure the IPv4 network. Legal Values • • Default 0 — Do not use DHCP 0 — IP Address, subnet mask and gateway are configured on the device. 1 — IP Address, subnet mask and gateway are assigned from the DHCP server. NOTE: If this object is modified, then the object cfgNicUseDhcp is also modified. cfgNicStaticNetmask (Read or Write) Table 122.
NOTE: This property is only valid if cfgDNSServersFromDHCP is set to 0 (FALSE). Legal Values • • Default 0 — Do not use DHCP 0 — IP Address, subnet mask and gateway are configured on the device. 1 — IP Address, subnet mask and gateway are assigned from the DHCP server. NOTE: If this object is modified, then the object cfgNicUseDhcp is also modified. cfgDNSStaticServer2 (Read or Write) Table 126. Details of cfgDNSStaticServer2 Description Specifies the static IP address for DNS server 2.
cfgRhostsFwUpdateTftpEnable (Read or Write) Table 129. Details of attribute - cfgRhostsFwUpdateTftpEnable Description Enables or disables firmware update from a network TFTP server. NOTE: This object is read-only for iDRAC Modular servers. Legal Values • • Default 1 1 — (TRUE) 0 — (FALSE) cfgRhostsFwUpdateIpAddr (Read or Write) Table 130. Details of attribute - cfgRhostsFwUpdateIpAddr Description Specifies the network TFTP server IPv4 or IPv6 address that is used for TFTP firmware update operations.
cfgRhostsSyslogEnable (Read or Write) Table 133. Details of attribute - cfgRhostsSyslogEnable Description To allow the RAC and SEL logs to be written to up to three remote syslog servers Enables or disables remote syslog. Legal Values • • Default 0 1 (TRUE) 0 (FALSE) cfgRhostsSyslogPort (Read or Write) Table 134. Details of attribute - cfgRhostsSyslogPort Description Remote syslog port number to use for writing the RAC and SEL logs to a remote syslog server.
Legal Values String from 0 to 63 characters. Valid host name or IPv4 or IPv6 address. Default cfgUserAdmin This group provides configuration information about the users allowed to access iDRAC through the available remote interfaces. This group provides configuration information about the users allowed to access CMC through the available remote interfaces. Up to 16 instances of the user group are allowed. Each instance represents the configuration for an individual user.
cfgUserAdminIpmiSerialPrivilege (Read or Write) Table 140. Details of cfgUserAdminIpmiSerialPrivilege Description The maximum privilege on the IPMI LAN channel. This object is applicable only for iDRAC on Rack and Tower Servers and not for iDRAC Enterprise on Blade Servers. Legal Values • • • • 2 (User) 3 (Operator) 4 (Administrator) 15 (No access) Default • • 4 (User 2) 15 (All others) cfgUserAdminPrivilege - Read or Write Table 141.
Chassis Configuration Administrator 0x0000002 User Configuration 0x0000004 Administrator Clear Logs Administrator 0x0000008 Chassis Control Administrator 0x0000010 Super User 0x0000020 Server Administrator 0x0000040 Test Alert User 0x0000080 Debug Command Administrator 0x0000100 Fabric A Administrator 0x0000200 Fabric B Administrator 0x0000400 Fabric C Administrator 0x0000800 Table 143.
cfgUserAdminUserName - Read or Write Table 144. Details of cfgUserAdminUserName attribute Description The name of the user for this index. Writing a string of double quotation mark (" ") disables the user. The string cannot contain / (forward slash), \ (backward slash), . (period), @ (at symbol), quotation marks, ; (semicolon), or ‘ (backward quotation mark). NOTE: This property value must be unique among user names. Legal Values A string of up to 16 ASCII characters.
Use this object with the config or getconfig subcommands. To use this object property, you must have the Chassis Configuration Administrator privileges. NOTE: You can configure a setting that does not have the hash sign (#) prefixed in the output. To modify a configurable object, use the —o option. The following sections provide information about the objects in the cfgEmailAlert group. cfgEmailAlertIndex - Read Only Table 148.
Default Example racadm getconfig -g cfgEmailAlert -i 2 # cfgEmailAlertIndex=1 cfgEmailAlertEnable=1 cfgEmailAlertAddress=kfulton@dell.com cfgEmailAlertName=Kevin Fulton cfgSessionManagement This group contains parameters to configure the number of sessions that can connect to iDRACCMC. One instance of the group is allowed. Displays current settings for and configures the idle timeout properties for web server, Telnet, SSH and RACADM sessions.
An expired web server session logs out the current session. Legal Values 60–10800 Default 1800 cfgSsnMgtSshIdleTimeout (Read or Write) Table 156. Details of cfgSsnMgtSshIdleTimeout attribute Description Defines the secure shell idle time-out. This property sets the amount of time (in seconds) that a connection is allowed to remain idle (there is no user input). The session is canceled if the time limit exceeds this property.
Use this object with the config or getconfig subcommands. To use this object property, you must have the Chassis Configuration Administrator privilege. The following sections provide information about the objects in the cfgSerial group. NOTE: The cfgSerial object group is applicable for iDRAC Enterprise on Blade Servers for only two properties — cfgSerialTelnetEnable=1 and cfgSerialSshEnable=1. cfgSerialBaudRate - Read or Write Table 158.
cfgSerialConsoleIdleTimeout - Read or Write Table 161. Details of cfgSerialConsoleIdleTimeout attribute Description The maximum number of seconds to wait before an idle serial session is disconnected. Legal Values • • Default 300 0 = No timeout 60–1920 1800 cfgSerialConsoleNoAuth - Read or Write Table 162. Details of cfgSerialConsoleNoAuth attribute Description Enables or disables the serial console login authentication.
Default 1 cfgSerialHistorySize - Read or Write Table 166. Details of cfgSerialHistorySize attribute Description Specifies the maximum size of the serial history buffer. Legal Values 0–8192 Default 8192 cfgSerialSshEnable - Read or Write Table 167. Details of cfgSerialSshEnable attribute Description Enables or disables the secure shell (SSH) interface.
Use this object with the config or getconfig subcommands. To use this object property, you must have the Chassis Configuration Administrator privilege. NOTE: You can configure a setting that does not have the hash sign (#) prefixed in the output. To modify a configurable object, use the —o option. The following sections provide information about the objects in the cfgOobSnmp group. cfgOobSnmpAgentCommunity (Read or Write) Table 169.
• cfgRacTuneTelnetPort • cfgRacTuneSshPort cfgRacTuneConRedirPort (Read or Write) Table 171. Details of cfgRacTuneConRedirPort Description To use for keyboard, mouse, video and Virtual Media traffic to iDRAC, specify the port. Legal Values 1024–65535 Default 5900 cfgRacTuneRemoteRacadmEnable (Read or Write) Table 172. Details of cfgRacTuneRemoteRacadmEnable attribute Description Enables or disables the Remote RACADM interface.
Legal Values 10–65535 NOTE: The following port numbers are reserved and cannot be used: 21, 68, 69, 111, 123, 161, 546, 801, 4096, 5988, 5989, 6900, 9000, and 60106. Default 443 cfgRacTuneIpRangeEnable (Read or Write) Table 176. Details of cfgRacTuneIpRangeEnable attribute Description Enables or disables the IPv4 Address Range validation feature. Legal Values • • Default 0 1 (TRUE) 0 (FALSE) cfgRacTuneIpRangeAddr (Read or Write) Table 177.
Legal Values 1–65535 10–65535 Default 22 cfgRacTuneTelnetPort (Read or Write) Table 180. Details of cfgRacTuneTelnetPort attribute Description Specifies the port number used for the Telnet interface. NOTE: The following port numbers are reserved and cannot be used: 21, 68, 69, 111, 123, 161, 546, 801, 4096, 5988, 5989, 6900, 9000, and 60106. Legal Values 1–65535 10–65535 Default 23 cfgRacTuneConRedirEnable (Read or Write) Table 181.
cfgRacTuneDaylightOffset (Read Only) Table 184. Details of cfgRacTuneDaylightOffset attribute Description Specifies the daylight savings offset (in minutes) to use for the RAC Time. This value is 0 if the time zone is not a Daylight Saving time zone.
cfgRacTuneIpRangeAddr=192.168.1.1 cfgRacTuneIpRangeMask=255.255.255.0 # cfgRacTuneTimezoneOffset=-18000 # cfgRacTuneDaylightOffset=3600 cfgRacTuneLocalServerVideo (Read or Write) Table 186. Details of cfgRacTuneLocalServerVideo Description Enables or disables the local server video. Legal Values • • Default 1 1 (TRUE — Enables) 0 (FALSE— Disables) cfgRacTuneLocalConfigDisable (Read or Write) Table 187.
Legal Values 0 — (If the user of the first session has not responded for session sharing request by subsequent user. The next session user gets an access denied error after the default timeout value of 30 seconds.) 1 — (If the user of the first session has not responded for session sharing request by subsequent user. The next session user gets a read-only access after the default timeout value of 30 seconds.
cfgVirMediaAttached (Read or Write) Table 193. Details of cfgVirMediaAttached Description This object is used to attach virtual devices to the system via the USB bus. When the devices are attached, the server recognizes valid USB mass storage devices attached to the system. Which is equivalent to attaching a local USB CDROM/floppy drive to a USB port on the system. When the devices are attached, they can be connected to the virtual devices remotely using iDRAC web interface or the CLI.
command is successful, use the cfgVFlashSDWriteProtect command. For more information, see cfgVFlashSDWriteProtect Read Only. Legal Values • • Default 0 1 (TRUE) 0(FALSE) cfgServerInfo This group allows you to select the BIOS first boot device and provides the option to start the selected device only once. This group allows you to display and configure a server in the chassis. Use this object with the config or getconfig subcommands.
cfgServerDNSIMCName (Read or Write) Table 200. Details of cfgServerDNSIMCName attribute Description Displays the DNS domain name for iDRAC or IMC. Legal Values A valid string values Default None Usage You can get and set the iDRAC DNS name using the cfgServerDNSIMCName attribute.
NOTE: First attach, to configure vFlash as First Boot Device.
To use this object property, you must have the Chassis Configuration Administrator privilege. NOTE: You can configure a setting that does not have the hash sign (#) prefixed in the output. To modify a configurable object, use the —o option. The following sections provide information about the objects in the cfgActiveDirectory. cfgADSSOEnable (Read or Write) Table 203. Details of cfgADSSOEnable attribute Description Enables or disables Active Directory single sign-on authentication on iDRACCMC.
cfgADRacName (Read or Write) Table 207. Details of cfgADRacName attribute Description Name of iDRAC as recorded in the Active Directory forest. Name of CMC as recorded in the Active Directory forest. Legal Values Any printable text string of up to 254 characters, with no white space. Default cfgADRacDomain (Read or Write) Table 208. Details of cfgADRacDomain attribute Description Active Directory Domain in which iDRAC resides. Active Directory Domain in which CMC resides.
Legal Values • • Default 1 1— (Enables Active Directory with the extended schema) 2— (Enables Active Directory with the standard schema) cfgADGlobalCatalog1 (Read or Write) Table 212. Details of cfgADGlobalCatalog1 Description To obtain user names, specify the Global Catalog server from which you want the iDRAC. This object is applicable only to iDRAC. Legal Values A string of up to 254 ASCII characters representing a valid IP address or a fully qualified domain name (FQDN).
cfgADDcSRVLookupEnable (Read or Write) Table 216. Details of cfgADDcSRVLookupEnable Description Configures iDRAC to use pre‑configured domain controllers or to use DNS to find the domain controller. If using pre‑configured domain controllers, then the domain controllers to use are specified under cfgAdDomainController1 ,cfgAdDomainController2 and cfgAdDomainController3.
cfgADGcRootDomain (Read or Write) Table 220. Details of cfgADGcRootDomain Description The names of the Active Directory root domain used for DNS look up, to locate Global Catalog servers. This object is applicable only to iDRAC. Legal Values String. Maximum length = 254 Default Null cfgLDAP This group allows you to configure settings related to the Lightweight Directory Access Protocol (LDAP). Use this object with the config or getconfig subcommands.
cfgLDAPPort (Read or Write) Table 223. Details of cfgLDAPPort attribute Description Port of LDAP over SSL. Non-SSL port is not supported. Legal Values 1–65535 Default 636 cfgLDAPBaseDN (Read or Write) Table 224. Details of cfgLDAPBaseDN attribute Description The domain name of the branch of the directory where all searches must start. Legal Values String. Maximum length = 254 Default Null cfgLDAPUserAttribute (Read or Write) Table 225.
Default 1 cfgLDAPBindDN (Read or Write) Table 228. Details of cfgLDAPBindDN attribute Description The distinguished name of a user used to bind to the server when searching for the login user's DN. If not provided, an anonymous bind is used. If necessary It is optional to support anonymous bind. NOTE: If cfgLDAPBindDN is [null] and cfgLDAPBindPassword is [null], then the iDRACCMC attempts an anonymous bind.
cfgLDAPSRVLookupDomainName (Read Only) Table 232. Details of cfgLDAPSRVLookupDomainName attribute Description To use in the SRV lookup, configure the domain name. Legal Values String of maximum length of 254 alphanumeric characters and hyphens. The string must begin with a letter. Default [null] cfgLDAPSRVLookupServiceName (Read or Write) Table 233. Details of cfgLDAPSRVLookupServiceName attribute Description To use in the SRV lookup, configure the service name.
Default None Example racadm getconfig -g cfgLDAPRoleGroup -o cfgLDAPRoleGroupDN -i 1 cn=everyone,ou=groups,dc=openldap,dc=com cfgLdapRoleGroupPrivilege (Read or Write) Table 236. Details of cfgLdapRoleGroupPrivilege Description A bit–mask defining the privileges associated with this particular group.
cfgSSADRoleGroupDomain (Read or Write) Table 239. Details of cfgSSADRoleGroupDomain attribute Description Active Directory Domain in which the Role Group resides. Legal Values Any printable text string of up to 254 characters, with no white space. Default cfgSSADRoleGroupPrivilege (Read or Write) Table 240. Details of cfgSSADRoleGroupPrivilege attribute Description Use the bit mask numbers listed in the table below to set role-based authority privileges for a Role Group.
cfgIpmiSol This group is used to configure the Serial Over LAN (SOL) capabilities of the system. The following sections provide information about the objects in the cfgIpmiSol group. cfgIpmiSolEnable (Read or Write) Table 243. Details of cfgIpmiSolEnable Description Enables or disables SOL. Legal Values • • Default 1 1(TRUE) 0(FALSE) cfgIpmiSolBaudRate (Read or Write) Table 244. Details of cfgIpmiSolBaudRate Description Specifies baud rate for serial communication over LAN.
cfgIpmiSolSendThreshold (Read or Write) Table 247. Details of cfgIpmiSolSendThreshold Description To buffer before sending an SOL data packet, specify the SOL threshold limit value and the maximum number of bytes. Legal Values 1–255 Default 255 cfgIpmiLan This group is used to configure the IPMI over LAN capabilities of the system. The following sections provide information about the objects in the cfgIpmiLan group. cfgIpmiLanEnable (Read or Write) Table 248.
cfgIpmiLanEncryptionKey (Read or Write) Table 251. Details of cfgIpmiLanEncryptionKey Description Specifies the IPMI encryption key. Legal Values A string of hexadecimal digits from 0 to 40 characters with no spaces. Only an even number of digits is allowed. Default 0000000000000000000000000000000000000000 cfgIpmiLanPetCommunityName (Read or Write) Table 252. Details of cfgIpmiLanPetCommunityName Description Specifies the SNMP community name for traps. Legal Values A string of up to 18 characters.
Default 0 cfgIpmiPef This group is used to configure the platform event filters available on the managed server. The event filters can be used to control policy related to actions that are triggered when critical events occur on the managed server. The following sections provide information about the objects in the cfgIpmiPef group. cfgIpmiPefName (Read Only) Table 256. Details of cfgIpmiPefName Description Specifies the name of the platform event filter. Legal Values A string of up to 255 characters.
Default 1 cfgIpmiPet This group is used to configure platform event traps on the managed server. The following sections provide information about the objects in the cfgIpmiPet group. cfgIpmiPetIndex (Read Only) Table 260. Details of cfgIpmiPetIndex Description Unique identifier for the index corresponding to the trap. Legal Values 1–4 Default The index value of a specific platform event trap. cfgIpmiPetAlertDestIpAddr (Read/Write) Table 261.
Default The index value. cfguserdomainname (Read Only) Table 264. Details of cfguserdomainname Description Specifies the Active Directory user domain name. Legal Values A string of up to 254 ASCII characters Default cfgServerPower This group provides several power management features. The following sections provide information about the objects in the cfgServerPower group. cfgServerPowerStatus (Read Only) Table 265.
cfgServerPowerCapEnable (Read or Write) Table 268. Details of cfgServerPowerCapEnable Description Enables or disables the user specified power budget threshold. This object is Read only for iDRAC Enterprise on Blade Servers. Legal Values • • Default 1 0 — Disables the user specified power budget threshold 1 — Enables the user specified power budget threshold cfgServerMinPowerCapacity (Read Only) Table 269.
cfgServerPowerConsumptionClear (Write Only) Table 273. Details of cfgServerPowerConsumptionClear Description Clears the current recorded power statistics. Legal Values 1 — Clears the Power Consumption Statistics Default None cfgServerPowerCapWatts (Read or Write) Table 274. Details of cfgServerPowerCapWatts Description Represents the server power threshold in Watts. NOTE: This value is applicable only if the cfgServerPowerCapEnable is set to 1.
cfgServerPowerLastDayAvg (Read Only) Table 278. Details of cfgServerPowerLastDayAvg Description Displays the average power value during the last day. Legal Values None Default Average power value during the last day. cfgServerPowerLastWeekAvg (Read Only) Table 279. Details of cfgServerPowerLastWeekAvg Description Displays the average power value during the last week. Legal Values None Default Average power value during the last week. cfgServerPowerLastHourMinPower (Read Only) Table 280.
cfgServerPowerLastHourMaxPower (Read Only) Table 282. Details of cfgServerPowerLastHourMaxPower Description Displays the maximum power value during the last hour. Legal Values Not applicable Default Maximum power value during the last hour. cfgServerPowerLastHourMaxTime (Read Only) Table 283. Details of cfgServerPowerLastHourMaxTime Description Displays the timestamp of maximum power value during the last hour.
Default Timestamp of the minimum power value during the last day. cfgServerPowerLastDayMaxPower (Read Only) Table 286. Details of cfgServerPowerLastDayMaxPower Description Displays the maximum power value during the last day. Legal Values Not applicable Default Maximum power value during the last day. cfgServerPowerLastDayMaxTime (Read Only) Table 287. Details of cfgServerPowerLastDayMaxTime Description Displays the timestamp of maximum power value during the last day.
• • • • Default YYYY = Year HH = hour MM = Minutes SS = Seconds Timestamp of the minimum power value during the last week. cfgServerPowerLastWeekMaxPower (Read Only) Table 290. Details of cfgServerPowerLastWeekMaxPower Description Displays the maximum power value during the last week. Legal Values None Default Maximum power value during the last week. cfgServerPowerLastWeekMaxTime (Read Only) Table 291.
This object is applicable only for iDRAC on Rack and Tower Servers and not for iDRAC Enterprise on Blade Servers. Legal Values None Default Difference between the available power and the peak power consumption. cfgServerActualAmperageConsumption (Read Only) Table 294. Details of cfgServerActualAmperageConsumption Description Displays the current power consumption. Legal Values Not applicable Default Current power consumption. cfgServerPeakAmperage (Read Only) Table 295.
cfgServerCumulativePowerConsumptionTimeStamp (Read Only) Table 298. Details of cfgServerCumulativePowerConsumptionTimeStamp Description Displays the timestamp of the cumulative power consumption. Legal Values A string of up to 32 characters. Time in the format: DD MM Date HH:MM:SS YYYY where, • • • • • • • Default DD = Day of the week MM= Month Date=Date YYYY = Year HH = hour MM=Minutes SS = Seconds Timestamp of the cumulative power consumption. cfgServerCumulativePowerClear (Write Only) Table 299.
NOTE: The getconfig subcommand always shows eight cfgServerPowerSupply indexes, even if two power supplies are installed in the system or the system supports a maximum of two PSUs. For the uninstalled and unsupported units, all the objects in the cfgServerPowerSupply group displays a value of 0. The following sections provide information about the objects in the cfgServerPowerSupply group. cfgServerPowerSupplyIndex Table 301. Details of cfgServerPowerSupplyIndex Description Specifies index of the PSU.
cfgServerPowerSupplyFwVer (Read Only) Table 305. Details of cfgServerPowerSupplyFwVer Description Displays the firmware version of the PSU, in the format x.xx.xxx. Legal Values A string up to 8 characters. Default Null cfgServerPowerSupplyCurrentDraw (Read Only) Table 306. Details of cfgServerPowerSupplyCurrentDraw Description Displays the instantaneous current consumption in 0.1 amps. Legal Values A string of up to 32 characters. Default 0 cfgServerPowerSupplyType Table 307.
cfgIPv6Address1 (Read or Write) Table 309. Details of cfgIPv6Address1 Description Specifies iDRAC IPv6 address. Specifies CMC IPv6 address. Legal Values String representing a valid IPv6 entry. Default : cfgIPv6Gateway (Read or Write) Table 310. Details of cfgIPv6Gateway attribute Description iDRAC gateway IPv6 address. CMC gateway IPv6 address. NOTE: This property is used only if cfgIPv6AutoConfig is set to 0 (false). Legal Values Specifies string representing a valid IPv6 entry.
0–128 Default 64 cfgIPv6LinkLocalAddress (Read Only) Table 313. Details of cfgIPv6LinkLocalAddress Description The iDRAC IPv6 link local address. Legal Values Specifies a string representing a valid IPv6 entry. Default : cfgIPv6Address2 (Read Only) Table 314. Details of cfgIPv6Address2 Description The iDRAC IPv6-second address. Legal Values A string representing a valid IPv6 entry. Default : cfgIPv6Address3 (Read Only) Table 315.
cfgIPv6Address6 (Read Only) Table 318. Details of cfgIPv6Address6 Description The iDRAC IPv6 sixth address. Legal Values String representing a valid IPv6 entry. Default : cfgIPv6Address7 (Read Only) Table 319. Details of cfgIPv6Address7 Description The iDRAC IPv6 seventh address. Legal Values String representing a valid IPv6 entry. Default : cfgIPv6Address8 (Read Only) Table 320. Details of cfgIPv6Address8 Description The iDRAC IPv6 eighth address.
cfgIPv6Address11 (Read Only) Table 323. Details of cfgIPv6Address11 Description The iDRAC IPv6 eleventh address. Legal Values String representing a valid IPv6 entry. Default : cfgIPv6Address12 (Read Only) Table 324. Details of cfgIPv6Address12 Description The iDRAC IPv6 twelfth address. Legal Values String representing a valid IPv6 entry. Default : cfgIPv6Address13 (Read Only) Table 325. Details of cfgIPv6Address13 Description The iDRAC IPv6 thirteenth address.
cfgIPv6DNSServersFromDHCP6 (Read or Write) Table 328. Details of cfgIPv6DNSServersFromDHCP6 attribute Description Specifies whether cfgIPv6DNSServer1 and cfgIPv6DNSServer2 are static or DHCP IPv6 addresses. NOTE: This property is used only if cfgIPv6AutoConfig is set to 1(true). Legal Values 1 (TRUE) 0 (FALSE) Default 0 1 cfgIPv6DNSServer1 (Read or Write) Table 329. Details of cfgIPv6DNSServer1 attribute Description Specifies the IPv6 DNS server address.
Default cfgIPv6StaticGateway (Read or Write) Table 332. Details of cfgIPv6StaticGateway Description Returns or sets gateway static IPv6 address. Legal Values Any IPv6 address Default cfgIPv6StaticPrefixLength (Read or Write) Table 333. Details of cfgIPv6StaticPrefixLength Description The prefix length for static IPv6 address 1. Legal Values 0–128 Default 64 cfgIPv6StaticAutoConfig (Read/Write) Table 334.
Default cfgIPv6StaticDNSServer2 (Read or Write) Table 337. Details of cfgIPv6StaticDNSServer2 Description Specifies the DNS server 2 static IPv6 address. Legal Values Any IPv6 address Default cfgIPv6DNSServer2 (Read or Write) Table 338. Details of cfgIPv6DNSServer2 attribute Description Specifies the IPv6 DNS server address. NOTE: This property is only valid if cfgIPv6DNSServersFromDHCP6 is set to 0 (false). Legal Values A string representing a valid IPv6 entry.
The following sections provide information about the objects in the cfgIPv6URL group. cfgIPv6URLstring (Read Only) Table 339. Details of cfgIPv6URLstring Description The iDRAC IPv6 URL. Legal Values A string of up to 80 characters. Default cfgIpmiSerial This group specifies properties used to configure the IPMI serial interface of the BMC. It is applicable only for iDRAC on Rack and Tower Servers and not for iDRAC Enterprise on Blade Servers. cfgIpmiSerialBaudRate (Read or Write) Table 340.
cfgIpmiSerialDeleteControl (Read or Write) Table 343. Details of cfgIpmiSerialDeleteControl Description Enables or disables delete control on the IPMI serial interface. Legal Values • • Default 0 0 (FALSE) 1 (TRUE) cfgIpmiSerialEchoControl (Read or Write) Table 344. Details of cfgIpmiSerialEchoControl Description Enables or disables echo control on the IPMI serial interface. Legal Values • • Default 1 0(FALSE) 1 (TRUE) cfgIpmiSerialFlowControl (Read or Write) Table 345.
• • Default 4 — LF-CR 5 — LF 1 cfgIpmiSerialLineEdit (Read or Write) Table 348. Details of cfgIpmiSerialLineEdit Description Enables or disables line editing on the IPMI serial interface. Legal Values • • Default 1 0(FALSE) 1(TRUE) cfgIpmiSerialInputNewLineSequence (Read or Write) Table 349. Details of cfgIpmiSerialInputNewLineSequence Description Specifies the input new line sequence specification for the IPMI serial interface.
Legal Values • • Default 0 1 (TRUE) 0 (FALSE) cfgNetTuning This group enables users to configure the advanced network interface parameters for the RAC NIC. When configured, the updated settings may take up to a minute to become active. This group enables users to configure the advanced network interface parameters. When configured, the updated settings may take up to a minute to become active.
• • 1 (100 MBit) 2 (1000 MBit) NOTE: You cannot manually set the Network Speed to 1000 MBit. This option is available only if cfgNetTuningNicAutoNeg is set to 1 (Enabled). Default 1 cfgNetTuningNicFullDuplex (Read or Write) Table 354. Details of cfgNetTuningNicFullDuplex attribute Description Specifies the duplex setting for the NIC. This property is used only if thecfgNetTuningNicAutoNeg is set to 0 (disabled).
cfgSensorRedundancyPolicy (Read or Write) Table 357. Details of cfgSensorRedundancyPolicy Description Sets the power supply redundancy policy. Legal Values • • • • • Default Any legal value at that particular execution instance. 2 — N/A, for systems that are not supported 3 — Non Redundant 4–1+1 Redundant 4–2+1 Redundant 16–2+2 Redundant cfgSensorRedundancyCapabilities (Read Only) Table 358.
To view the properties of this group, enable the vFlash using the command: racadm config -g cfgvFlashSD -o cfgvFlashSDEnable 1 The following sections provide information about the objects in the cfgVFlashSD group. cfgVFlashSDInitialized (Read Only) Table 360. Details of cfgVFlashSDInitialized Description Displays whether an SD card is initialized. Legal Values • • Default None 0 1 cfgVFlashSDEnable (Read or Write) Table 361.
cfgVFlashSDAvailableSize (Read Only) Table 364. Details of cfgVFlashSDAvailableSize Description Displays the available memory (in MB) on the vFlash SD card that can be used to create new partitions. Legal Values A string of up to 64 characters. Default If the card is not initialized, default is 0. If initialized, displays the unused memory on the card. cfgVFlashSDHealth (Read Only) Table 365. Details of cfgVFlashSDHealth Description Displays the current health status of the vFlash SD card.
cfgVFlashPartitionSize (Read Only) Table 368. Details of cfgVFlashPartitionSize Description Displays the size of the partition. Legal Values 1 MB to 4 GB Default None cfgVFlashPartitionEmulationType (Read or Write) Table 369. Details of cfgVFlashPartitionEmulationType Description View or modify the emulation type for the partition. Legal Values String: • • • Default HDD Floppy CD-DVD None cfgVFlashPartitionFlashOSVolLabel (Read Only) Table 370.
Legal Values • • Default 0 0 (Read Only) 1 (Read-Write) cfgVFlashPartitionAttachState (Read or Write) Table 373. Details of cfgVFlashPartitionAttachState Description View or modify the partition to attached or detached. NOTE: Detaching the vFlashPartition by setting the cfgVFlashPartitionAttachState to 0 does not require a license. Legal Values • • Default 0 — Detached 1 — Attached 0 — Detached cfgLogging This group contains parameters to enable or disable the OEM event log filtering.
cfgRacSecCsrOrganizationName (Read or Write) Table 376. Details of cfgRacSecCsrOrganizationName attribute Description Specifies the CSR Organization Name (O). Legal Values A string of up to 64 characters. Default cfgRacSecCsrOrganizationUnit (Read or Write) Table 377. Details of cfgRacSecCsrOrganizationUnit attribute Description Specifies the CSR Organization Unit (OU). Legal Values A string of up to 64 characters. Default cfgRacSecCsrLocalityName (Read or Write) Table 378.
cfgRacSecCsrEmailAddr (Read or Write) Table 381. Details of cfgRacSecCsrEmailAddr attribute Description Specifies the CSR email address. Legal Values A string of up to 64 characters. Default Example racadm config -g cfgRacSecurity cfgRacSecCsrKeySize=1024 cfgRacSecCommonName= cfgRacSecOrganizationName= cfgRacSecOrganizationUnit= cfgRacSecLocalityName= cfgRacSecStateName= cfgRacSecCountryCode= cfgRacSecEmailAddr= cfgRacSecCsrKeySize (Read or Write) Table 382.
4 Database Objects With Get and Set Commands This chapter provides the database groups and objects that must be used with the get or set subcommands. When using the objects, they must begin with FQDD or FQDD alias. The set operations for iDRAC, Lifecycle Controller and system objects do not require server restart. However, the set operations for NIC and BIOS objects are staged and job creation and server restart is required to apply and commit the pending values.
4; 5Retries - 5;6Retries- 6; IndefiniteRetries, Default - NoRetry Required License -- RACADM Dependency -- None BootStrapType system. Usage AutoDetect Required License Dependency -- Specify the boot strap method used to boot to the operating -- AutoDetect - 0;BBS - 1; Int18h - 2; Int19h- 3; Default -- RACADM -- None HideSetupPrompt -- Specifies whether to display or hide the legacy Option ROM setup prompt during system Power On Self Test (POST).
• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • System.Backplane System.ChassisControl System.ChassisInfo System.OpenIDConnectServer System.QuickSync System.LCD System.Location System.OpenIDConnectServer System.Power System.Power.Supply System.ServerOS System.ThermalSettings System.ThermalConfig LifecycleController.LCAttributes iDRAC.ActiveDirectory iDRAC.ADGroup iDRAC.ASRConfig iDRAC.AutoOSLock iDRAC.EmailAlert iDRAC.IMC iDRAC.Info iDRAC.
• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • 232 iDRAC.Telnet iDRAC.Time iDRAC.Tuning iDRAC.Update iDRAC.USB iDRAC.UserDomain iDRAC.Users iDRAC.vflashpartition iDRAC.vflashsd iDRAC.VirtualConsole iDRAC.VirtualMedia iDRAC.VNCServer iDRAC.WebServer BIOS.BiosBootSettings BIOS.EmbServerMgmt BIOS.IntegratedDevices BIOS.MemSettings BIOS.MiscSettings BIOS.NetworkSettings BIOS.OneTimeBoot BIOS.ProcSettings BIOS.ProxyAttributes BIOS.
System.Backplane The objects in this group manage the backplane. System.Backplane.BackplaneBusMode (Read Only) Table 383. Details of System.Backplane.BackplaneBusMode Description Indicates the backplane Serial General Purpose Input or Output (SGPIO) mode. Legal Values • • • Default Value 1 — I2C Write Privilege Configure iDRAC 0 — Unknown 1 — I2C 2 — SGPIO License Required iDRAC Express or iDRAC Enterprise Dependency None System.
Default Value None Write privilege Not Applicable License Required Not Applicable Dependency None System.ChassisInfo.Name (Read Only) Table 386. Details of System.ChassisInfo.Name Description Provides the name of the chassis. For example: CMC-nobel01. Legal Values String of up to 62 ASCII characters Default Value None Write Privilege Not Applicable License Required Not Applicable Dependency None System.ChassisInfo.ServiceTag (Read Only) Table 387. Details of System.ChassisInfo.
System.OpenIDConnectServer.ClientURI (Read or Write) Table 389. Details ofSystem.OpenIDConnectServer.ClientURI attribute Description Indicates the Client URI. Legal Values String of up to 1024 ASCII characters Default Value Not Applicable Write Privilege Not Applicable License Required RACADM Dependency None System.OpenIDConnectServer.DiscoveryURL (Read or Write) Table 390. Details of iSystem.OpenIDConnectServer.DiscoveryURL attribute Description Indicates the discovery URL.
License Required RACADM Dependency None System.OpenIDConnectServer.RegistrationDetails(Read or Write) Table 393. Details of System.OpenIDConnectServer.RegistrationDetails attribute Description Indicates the registration details. Legal Values String of up to 1024 ASCII characters Default Value Not Applicable Write Privilege Not Applicable License Required RACADM Dependency None System.OpenIDConnectServer.RegistrationStatus (Read or Write) Table 394. Details of System.OpenIDConnectServer.
System.QuickSync.Access (Read or Write) Table 396. Details of System.QuickSync.Access Description Configures the accessibility using Quick Sync on the server. Legal Values • • • Default Value 2 — Read-write Write Privilege Server Control 0 — Disabled 1 — Read-only 2 — Read-write License Required iDRAC Express or iDRAC Enterprise Dependency To configure, the System.QuickSync.Presence property must indicate Present System.QuickSync.InactivityTimeout (Read or Write) Table 397. Details of System.
Dependency None System.LCD This group enables you to manage the front panel LCD user string settings. The following section provides information about the objects in the System.LCD group. NOTE: The System.LCD get and set command works on iDRAC on Blade Server, even if the LCD is not present on the server. NOTE: You can change the LCD group attributes for monolithic servers even if the LCD is not present on servers. System.LCD.Configuration (Read or Write) Table 400. Details of System.LCD.
System.LCD.CurrentDisplay (Read Only) Table 402. Details of System.LCD.CurrentDisplay Description The string currently displayed on the LCD. Legal Values None Default Value Not Applicable Write Privilege Not Applicable License Required iDRAC Express or iDRAC Enterprise Dependency None System.lcd.FrontPanelLocking (Read or Write) Table 403. Details of system.lcd.
Write Privilege Configure iDRAC License Required iDRAC Express or iDRAC Enterprise Dependency None System.LCD.QualifierWatt (Read or Write) Table 406. Details of System.LCD.QualifierWatt Description Specifies the system Watt qualifier. Legal Values • • Default Value Watts Write Privilege Configure iDRAC Watts BTU per hour License Required iDRAC Express or iDRAC Enterprise Dependency None System.LCD.UserDefinedString (Read or Write) Table 407. Details of System.LCD.
System.Location.DataCenter (Read or Write) Table 409. Details of System.Location.DataCenter Description Indicates name of the data center where the system is located. Legal Values String of up to 128 ASCII characters Default Value Not Applicable Write Privilege Configure iDRAC License Required iDRAC Express or iDRAC Enterprise Dependency None System.Location.DeviceSize (Read Only) Table 410. Details of System.Location.DeviceSize Description Indicates server chassis size.
License Required iDRAC Express or iDRAC Enterprise Dependency None System.Location.RoomName (Read or Write) Table 413. Details of System.Location.RoomName Description Room name where the system is located. Legal Values String of up to 128 ASCII characters Default Value Not Applicable Write Privilege Configure iDRAC License Required iDRAC Express or iDRAC Enterprise Dependency None System.Location.Chassis.Name (Read Only) Table 414. Details of System.Location.Chassis.
System.OpenIDConnectServer.DiscoveryURL (Read or Write) Table 416. Details of iSystem.OpenIDConnectServer.DiscoveryURL attribute Description Indicates the discovery URL. Legal Values String of up to 1024 ASCII characters Default Value Not Applicable Write Privilege Not Applicable License Required RACADM Dependency None System.Power This group provides power management features for iDRAC. The following section provides information about the objects in this group.
System.Power.Avg.LastDay (Read Only) Table 419. Details of System.Power.Avg.LastDay Description Indicates the average power value during the last day. Legal Values Values: 1–65535 Default Value Average power value during the last day. Write Privilege Not Applicable License Required iDRAC Express or iDRAC Enterprise Dependency None System.Power.Avg.LastHour (Read Only) Table 420. Details of System.Power.Avg.LastHour Description Displays the average power value during the last hour.
License Required iDRAC Express or iDRAC Enterprise Dependency None System.Power.Cap.ActivePolicy.Name (Read Only) Table 423. Details of System.Power.Cap.ActivePolicy.Name Description Displays the Active Power Cap Policy Name Legal Values String of up to 128 ASCII characters Default Value Not Applicable Write Privilege Not Applicable License Required iDRAC Express or iDRAC Enterprise Dependency None System.Power.Cap.ActivePolicy.Watts (Read Only) Table 424. Details of System.Power.Cap.
System.Power.Cap. Enable (Read or Write) Table 426. Details of System.Power.Cap. Enable Description Enables or disables user specified power budget threshold configuration. Legal Values • • Default Value 1 — Enabled Write Privilege Configure iDRAC 0 — Disabled 1 — Enabled License Required iDRAC Express or iDRAC Enterprise Dependency None System.Power.Cap.MaxThreshold (Read Only) Table 427. Details of System.Power.Cap.
Legal Values Values: 0–100 Default Value Server power threshold in percentage. Write Privilege Configure iDRAC License Required iDRAC Express or iDRAC Enterprise Dependency Enable System.Power.Cap.Enable System.Power.Redundancypolicy (Read or Write) Table 430. Details of System.Power.Redundancypolicy Description Selects the redundancy policy.
System.Power.EnergyConsumption (Read Only) Table 432. Details of System.Power.EnergyConsumption Description Represents the Cumulative power consumption by the blade or system. Legal Values Values: 1–65535 Default Value Cumulative power consumption Write Privilege Configure iDRAC License Required iDRAC Express or iDRAC Enterprise Dependency None System.Power.EnergyConsumption.Clear (Read or Write) Table 433. Details of System.Power.EnergyConsumption.
Legal Values • • Default Value 1 — Enabled Write Privilege Configure iDRAC License Required iDRAC Express or iDRAC Enterprise Dependency None 0 — Disabled 1 — Enabled System.Power.Hotspare.PrimaryPSU (Read or Write) Table 436. Details of System.Power.Hotspare.PrimaryPSU Description Represents the primary PSU selection. NOTE: This object is supported only for iDRAC on Rack and Tower servers.
License Required iDRAC Express or iDRAC Enterprise Dependency None System.Power.Max.Headroom (Read Only) Table 439. Details of System.Power.Max.Headroom Description Displays the difference between the available power and the peak power consumption. NOTE: This object is not applicable on iDRAC on Modular servers. Legal Values Values: 1–65535 Default Value Difference between the available power and the peak power consumption.
System.Power.Max.LastHour (Read Only) Table 442. Details of System.Power.Max.LastHour Description Displays the maximum power value during the last hour. Legal Values Values: 1–65535 Default Value Maximum power value during the last hour. Write Privilege Not Applicable License Required iDRAC Express or iDRAC Enterprise Dependency None System.Power.Max.LastHour.TimeStamp (Read Only) Table 443. Details of System.Power.Max.LastHour.
License Required iDRAC Express or iDRAC Enterprise Dependency None System.Power.Max. Power (Read Only) Table 446. Details of System.Power.Max. Power Description The server consumes maximum power, because the last value was cleared. Legal Values Values: 1–65535 Default Value Peak power consumption of the server. Write Privilege Configure iDRAC License Required iDRAC Express or iDRAC Enterprise Dependency None System.Power.Max.Power.Timestamp (Read Only) Table 447. Details of System.Power.Max.
System.Power.Min.LastDay (Read Only) Table 449. Details of System.Power.Min.LastDay Description Displays the minimum power during the last day. Legal Values Values: 1–65535 Default Value Minimum power value during the last day. Write Privilege Not Applicable License Required iDRAC Express or iDRAC Enterprise Dependency None System.Power.Min.LastDay.TimeStamp (Read Only) Table 450. Details of System.Power.Min.LastDay.TimeStamp Description Displays the minimum power value during the last day.
License Required iDRAC Express or iDRAC Enterprise Dependency None System.Power.Min.LastWeek (Read Only) Table 453. Details of System.Power.Min.LastWeek Description Indicates the minimum power during the last week. Legal Values Values: 1–65535 Default Value Minimum power value during the last week. Write Privilege Not Applicable License Required iDRAC Express or iDRAC Enterprise Dependency None System.Power.Min.LastWeek.TimeStamp (Read Only) Table 454. Details of System.Power.Min.LastWeek.
System.Power.PFCEnable (Read or Write) Table 456. Details of System.Power.PFCEnable Description Enables the power factor correction enable. NOTE: • This object is supported only for iDRAC on Rack and Tower servers. • This object is applicable only if System.Power.Cap.Enable is set to 1. Legal Values • • Default Value 0 — Disabled Write Privilege Configure iDRAC 0 — Disabled 1 — Enabled License Required iDRAC Express or iDRAC Enterprise Dependency None System.Power.
Default 0 — None Write Privilege Not Applicable License Required Not Applicable Dependency Not Applicable System.Power.Realtime.Headroom (Read Only) Table 459. Details of System.Power.Realtime.Headroom Description Displays the difference of available power and the current power consumed. Legal Values Integral values: 1-65535 Default Value Default Write Privilege Not Applicable License Required iDRAC Express or iDRAC Enterprise Dependency Not Applicable System.Power.Realtime.
System.Power.Supply.CurrentDraw (Read Only) Table 462. Details of System.Power.Supply.CurrentDraw Description Displays the instantaneous current consumption in 0.1 amps. Legal Values String of up to 254 ASCII characters Default Value Not Applicable Write Privilege Not Applicable License Required iDRAC Express or iDRAC Enterprise Dependency None System.Power.Supply.FwVer (Read Only) Table 463. Details of System.Power.Supply.FwVer Description Displays the firmware version of the PSU.
Dependency Not Applicable System.Power.Supply.[i].Status (Read Only) Table 466. Details of System.Power.Supply.[i].Status Description Displays the status of the PSU. Legal Values • • • • Default 0 — absent Write Privilege Not Applicable 0 — absent 1 — present and OK 2 — failure 3 — predictive failure License Required Not Applicable Dependency Not Applicable System.Power.Supply.[i].Type (Read Only) Table 467. Details of System.Power.Supply.[i].
Legal Values Integer > 0 Default 0 Write Privilege Not Applicable License Required Not Applicable Dependency Not Applicable System.ServerOS Use the objects in this group to manage the host operating system's name and version details. System.ServerOS.HostName (Read or Write) Table 470. Details of System.ServerOS.HostName Description Displays the host name of the managed server.
Dependency None System.ServerOS.ServerPoweredOnTime (Read Only) Table 473. Details of System.ServerOS.ServerPoweredOnTime Description Indicates the time (in seconds) from when the operating system is turned ON. Legal Values Any integer value indicating the system powered on time duration. Default Value 0 Write Privilege Configure iDRAC License Required iDRAC Express or iDRAC Enterprise Dependency None System.
System.ThermalSettings.MinimumFanSpeed (Read or Write) Table 476. Details of System.ThermalSettings.MinimumFanSpeed Description Specifies the minimum fan speed required. NOTE: This attribute is platform dependent. Legal Values MFSMinimumLimit — MFSMaximumLimit Default Value 0 Write Privilege Not Applicable License Required iDRAC Express or iDRAC Enterprise Dependency None System.ThermalSettings.FanSpeedOffset (Read or Write) Table 477. Details of System.ThermalSettings.
NOTE: This attribute is platform dependent. Legal Values Integral Values: 0 – 100 Default Value 0 License Required iDRAC Express or iDRAC Enterprise Dependency None System.ThermalSettings.FanSpeedHighOffsetVal (Read Only) Table 480. Details of System.ThermalSettings.FanSpeedHighOffsetVal Description Indicates the percentage range for the high fan offset speed. NOTE: This attribute is platform dependent.
System.ThermalSettings.MFSMaximumLimit (Read Only) Table 483. Details of System.ThermalSettings.MFSMaximumLimit Description Indicates the maximum limit for MFS. NOTE: This attribute is platform dependent. Legal Values Integral Values: 1 - 100 Default Value 255 License Required iDRAC Express or iDRAC Enterprise Dependency None System.ThermalSettings.ThermalProfile (Read or Write) Table 484. Details of System.ThermalSettings.ThermalProfile Description Sets the thermal base algorithm.
System.ThermalConfig.CriticalEventGenerationInterval (Read or Write) Table 486. Details of System.ThermalConfig.CriticalEventGenerationInterval Description Indicates the time interval (in days) for critical events to be generated. Legal Values Integral Values: 0-365 Default Value 30 Write Privilege Configure iDRAC License Required iDRAC Express or iDRAC Enterprise Dependency None System.ThermalConfig.EventGenerationInterval (Read or Write) Table 487. Details of System.ThermalConfig.
LifecycleController.LCAttributes.autobackup (Read or Write) Table 489. Details of LifecycleController.LCAttributes.autobackup Description Enables or disables the automatic backup scheduler. Legal Values • • Default Value 0 — Disabled Write Privilege Server Control 0 — Disabled 1 — Enabled License Required iDRAC Enterprise Dependency None LifecycleController.LCAttributes.AutoDiscovery (Read Only) Table 490. Details of LifecycleController.LCAttributes.
Set the value to 1, and restart the server to reset the BIOS attributes to factory default. After the server restart, the value is set to 0 by default. Legal Values • • Default Value 0 — FALSE Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency None 0 — FALSE 1 — TRUE LifecycleController.LCAttributes.CollectSystemInventory OnRestart (Read or Write) Table 493. Details of LifecycleController.LCAttributes.
• 1—On Default Value 1—On License Required iDRAC Enterprise Dependency None LifecycleController.LCAttributes.IPChangeNotifyPS (Read or Write) Table 496. Details of LifecycleController.LCAttributes.IPChangeNotifyPS Description Notifies the provisioning server about the change in IP address. Legal Values • • Default Value 0 — Off Write Privilege Configure iDRAC License Required iDRAC Enterprise Dependency None 0 — Off 1 — On LifecycleController.LCAttributes.Licensed (Read Only) Table 497.
LifecycleController.LCAttributes.ProvisioningServer (Read or Write) Table 499. Details of LifecycleController.LCAttributes.ProvisioningServer Description Specifies the Provisioning Server Address. Legal Values String of up to 255 ACSII characters Default Value Not Applicable Write Privilege Configure iDRAC License Required iDRAC Enterprise Dependency None LifecycleController.LCAttributes.PartConfigurationUpdate (Read or Write) Table 500. Details of LifecycleController.LCAttributes.
LifecycleController.LCAttributes.SystemID (Read Only) Table 502. Details of LifecycleController.LCAttributes.SystemID Description Specifies the Dell System ID. Legal Values Not Applicable Default Value None Write Privilege Not Applicable License Required iDRAC Enterprise Dependency None LifecycleController.LCAttributes.UserProxyName (Read and Write) Table 503. Details of LifecycleController.LCAttributes.UserProxyName Description Enables to set user proxy name if the default is not set.
LifecycleController.LCAttributes.UserProxyServer (Read and Write) Table 506. Details of LifecycleController.LCAttributes.UserProxyServer Description Enables to set user proxy server if the default is not set. Legal Values String of up to 64 ASCII characters Default Value None License Required iDRAC Enterprise Dependency None LifecycleController.LCAttributes.UserProxyType (Read and Write) Table 507. Details of LifecycleController.LCAttributes.
iDRAC.ActiveDirectory To manage the configuration of the iDRAC Active Directory features, use the objects in this group. iDRAC.ActiveDirectory.AuthTimeout (Read or Write) Table 509. Details of iDRAC.ActiveDirectory.AuthTimeout Description To wait for ActiveDirectory authentication requests to complete before timing out, specify the time in seconds.
iDRAC.ActiveDirectory.DCLookupDomainName (Read or Write) Table 512. Details of iDRAC.ActiveDirectory.DCLookupDomainName Description The configured search domain is used when DCLookupByUserDomain is disabled. Legal Values String of up to 254 ASCII characters Default Value Not Applicable Write Privilege Configure iDRAC and configure user License Required iDRAC Enterprise Dependency None iDRAC.ActiveDirectory.DCLookupEnable (Read or Write) Table 513. Details of iDRAC.ActiveDirectory.
iDRAC.ActiveDirectory.DomainController2 (Read or Write) Table 515. Details of iDRAC.ActiveDirectory.DomainController2 Description FQDN that stores the address of the active directory domain controller 2 Legal Values String of up to 254 ASCII characters Default Value Not Applicable Write Privilege Configure iDRAC and configure user License Required iDRAC Enterprise Dependency None iDRAC.ActiveDirectory.DomainController3 (Read or Write) Table 516. Details of iDRAC.ActiveDirectory.
Default Value 0 — Disabled Write Privilege Configure iDRAC and configure user License Required iDRAC Enterprise Dependency Cannot be enabled unless one of the following is configured: • • • • IPv4.DNS1 IPv4.DNS2 IPv6.DNS1 IPv6.DNS2 iDRAC.ActiveDirectory.GCRootDomain (Read or Write) Table 519. Details of iDRAC.ActiveDirectory.GCRootDomain Description The names of the Active Directory root domain used for DNS look up.
Dependency None iDRAC.ActiveDirectory.GlobalCatalog3 (Read or Write) Table 522. Details of iDRAC.ActiveDirectory.GlobalCatalog3 Description To obtain user names, specifies the Global Catalog server from which you want the iDRAC. Legal Values String of up to 254 ASCII characters Default Value Not Applicable Write Privilege Configure iDRAC and configure user License Required iDRAC Enterprise Dependency None iDRAC.ActiveDirectory.RacDomain (Read or Write) Table 523. Details of iDRAC.
• 2 — Standard Schema Default Value 1 — Extended Schema Write Privilege Configure iDRAC and configure user License Required iDRAC Enterprise Dependency None iDRAC.ActiveDirectory.SSOEnable (Read or Write) Table 526. Details of iDRAC.ActiveDirectory.SSOEnable Description Enables or disables Active Directory single sign-on authentication on iDRAC.
Write Privilege Configure iDRAC and configure user License Required iDRAC Enterprise Dependency None iDRAC.ADGroup.Privilege (Read or Write) Table 529. Details of iDRAC.ADGroup.Privilege Description Role-based authority privileges for a Role Group. Legal Values Integral values: 0–511 (0x1FF) Default Value 0 Write Privilege Configure iDRAC and configure user License Required iDRAC Enterprise Dependency None iDRAC.
License Required iDRAC Express or iDRAC Enterprise Dependency None iDRAC.EmailAlert The objects in this group configure email alerting capabilities. This group is indexed from 1 to 4. iDRAC.EmailAlert.Address (Read or Write) Table 531. Details of iDRAC.EmailAlert.Address Description Specifies the destination email address for email alerts.
iDRAC.IMC This group contains the attributes that provides details about IMC configuration. iDRAC.IMC.AdministrativeState (Read or Write) Description Enable or Disable Administrative State of IMC Legal Values • • Default Value 0 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy iDRAC NIC has to be in shared mode to enable OS to iDRAC pass through. Disabled-0 Enabled-1 iDRAC.Info To manage information about iDRAC being queried, use these objects in the group. iDRAC.Info.
iDRAC.Info.Name (Read or Write) Table 536. Details of iDRAC.Info.Name Description User assigned name identifying this controller. Legal Values String of up to 15 ASCII characters Default Value Not Applicable Write Privilege Configure iDRAC License Required iDRAC Express or iDRAC Enterprise Dependency None iDRAC.Info.Product (Read or Write) Table 537. Details of iDRAC.Info.Product Description String identifying the Product.
License Required iDRAC Express or iDRAC Enterprise Dependency None iDRAC.Info.ServerGen (Read or Write) Table 540. Details of iDRAC.Info.ServerGen Description Indicates the server generation. Legal Values String of up to 12 ASCII characters Default Value Not Applicable Write Privilege Configure iDRAC License Required iDRAC Express or iDRAC Enterprise Dependency None iDRAC.IOIDOpt The objects in this group manage the IOIDOpt attributes. iDRAC.IOIDOpt.
Legal Values • • • • • • • • Default Value 7— WarmReset, PowerGoodReset, ACPowerLoss Write Privilege Configure iDRAC and Server Control 0— None 1— WarmReset 2— PowerGoodReset 3— WarmReset, PowerGoodReset 4— ACPowerLoss 5— WarmReset, ACPowerLoss 6— PowerGoodReset, ACPowerLoss 7— WarmReset, PowerGoodReset, ACPowerLoss License Required iDRAC Express or iDRAC Enterprise Dependency IOIDOptEnable attribute must be enabled. iDRAC.IOIDOpt.StorageTargetPersistencePolicy (Read or Write) Table 543.
Write Privilege Configure iDRAC License Required iDRAC Express or iDRAC Enterprise Dependency To configure, the iDRAC.IOIDOpt.Enable property must indicate Enabled. iDRAC.IOIDOpt.VirtualAddressPersistencePolicyNonAuxP wrd (Read or Write) Table 545. Details of iDRAC.IOIDOpt.VirtualAddressPersistencePolicyNonAuxPwrd Description Applied for the Non-Aux powered devices, which persist the virtual address on warm reset.
Write Privilege Configure iDRAC License Required iDRAC Express or iDRAC Enterprise Dependency None iDRAC.IPBlocking.FailWindow (Read or Write) Table 548. Details of iDRAC.IPBlocking.FailWindow Description Defines the time span in seconds that the unsuccessful attempts are counted. Legal Values Integral values from 10 to 65535 Write Privilege Configure iDRAC License Required iDRAC Express or iDRAC Enterprise Dependency None iDRAC.IPBlocking.PenaltyTime (Read or Write) Table 549. Details of iDRAC.
Legal Values • • Default Value 0 — Disabled Write Privilege Configure iDRAC 0 — Disabled 1 — Enabled License Required iDRAC Express or iDRAC Enterprise Dependency None iDRAC.IPBlocking.RangeMask (Read or Write) Table 552. Details of iDRAC.IPBlocking.RangeMask Description Standard IP mask values with left-justified bits. Legal Values Valid IPv4 Address Mask Default Value 255.255.255.0 Write Privilege Configure iDRAC License Required iDRAC Express or iDRAC Enterprise Dependency None iDRAC.
Default Value Public Write Privilege Configure iDRAC License Required iDRAC Express or iDRAC Enterprise Dependency None iDRAC.IPMILan.Enable (Read or Write) Table 555. Details of iDRAC.IPMILan.Enable Description Enables or disables the IPMI over LAN interface. Legal Values • • Default Value 0 — Disabled Write Privilege Configure iDRAC 0 — Disabled 1 — Enabled License Required iDRAC Express or iDRAC Enterprise Dependency None iDRAC.IPMILan.EncryptionKey (Read or Write) Table 556.
Dependency None iDRAC.IPMISerial To configure the IPMI serial interface, use this objects in this group. NOTE: This is supported only for rack and tower systems. iDRAC.IPMISerial.BaudRate (Read or Write) Table 558. Details of iDRAC.IPMISerial.BaudRate Description Specifies the baud rate for serial connection over IPMI. Legal Values • • • • Default Value 115200 Write Privilege Configure iDRAC 9600 19200 57600 115200 License Required iDRAC Express or iDRAC Enterprise Dependency None iDRAC.
Write Privilege Configure iDRAC License Required iDRAC Express or iDRAC Enterprise Dependency None iDRAC.IPMISerial.DeleteControl (Read or Write) Table 561. Details of iDRAC.IPMISerial.DeleteControl Description Enables or disables delete control on the IPMI serial interface. Legal Values • • Default Value 0 — Disabled Write Privilege Configure iDRAC 0 — Disabled 1 — Enabled License Required iDRAC Express or iDRAC Enterprise Dependency None iDRAC.IPMISerial.
iDRAC.IPMISerial.HandshakeControl (Read or Write) Table 564. Details of iDRAC.IPMISerial.HandshakeControl Description Enables or disables the IPMI terminal mode handshake control. Legal Values • • Default Value 1 — Enabled Write Privilege Configure iDRAC 0 — Disabled 1 — Enabled License Required iDRAC Express or iDRAC Enterprise Dependency None iDRAC.IPMISerial.InputNewLineSeq (Read or Write) Table 565. Details of iDRAC.IPMISerial.
Legal Values • • • • • • Default Value 1 — CR-LF Write Privilege Configure iDRAC 0 — None 1 — CR-LF 2 — Null 3 — CR 4 — LF-CR 5— LF License Required iDRAC Express or iDRAC Enterprise Dependency None iDRAC.IPMISOL Use the objects in this group to configure the SOL capabilities of the system. iDRAC.IPMISOL.AccumulateInterval (Read or Write) Table 568. Details of iDRAC.IPMISOL.
iDRAC.IPMISOL.Enable (Read or Write) Table 570. Details of iDRAC.IPMISOL.Enable Description Enables or disables SOL. Legal Values • • Default Value 1 — Enabled Write Privilege Configure iDRAC 0 — Disabled 1 — Enabled License Required iDRAC Express or iDRAC Enterprise Dependency None iDRAC.IPMISOL.MinPrivilege (Read or Write) Table 571. Details of iDRAC.IPMISOL.MinPrivilege Description Specifies the minimum privilege level required for serial access.
iDRAC.IPv4.Address (Read or Write) Table 573. Details of iDRAC.IPv4.Address Description The current IPv4 address assigned to iDRAC. Legal Values Valid IPv4 Address ` Default Value 192.168.0 Write Privilege Configure iDRAC License Required iDRAC Express or iDRAC Enterprise Dependency Cannot be set unless IPv4.DHCPEnable is disabled. iDRAC.IPv4.DHCPEnable (Read or Write) Table 574. Details of iDRAC.IPv4.DHCPEnable Description Specifies if DHCP is used to assign the iDRAC IPv4 address.
Default Value 0.0.0.0 Write Privilege Configure iDRAC License Required iDRAC Express or iDRAC Enterprise Dependency Cannot be set unless IPv4.DNSFromDHCP is disabled. iDRAC.IPv4.DNSFromDHCP (Read or Write) Table 577. Details of iDRAC.IPv4.DNSFromDHCP Description Specifies if the DNS server IPv4 addresses must be assigned from the DHCP server on the network.
iDRAC.IPv4.Netmask (Read or Write) Table 580. Details of iDRAC.IPv4.Netmask Description The subnet mask used for the iDRAC IPv4 address. Legal Values Valid IPv4 netmask Default Value 255.255.255.0 Write Privilege Configure iDRAC License Required iDRAC Express or iDRAC Enterprise Dependency Cannot be set unless IPv4.DHCPEnable is disabled. iDRAC.IPv4Static Use the objects in this group to manage the IPv4 Static configuration properties of iDRAC. iDRAC.IPv4Static.Address (Read or Write) Table 581.
iDRAC.IPv4Static.DNS2 (Read or Write) Table 583. Details of iDRAC.IPv4Static.DNS2 Description Statically configurable DNS Server 2. Legal Values Valid IPv4 Address Default Value 0.0.0.0 Write Privilege Configure iDRAC License Required iDRAC Express or iDRAC Enterprise Dependency None iDRAC.IPv4Static.DNSFromDHCP (Read or Write) Table 584. Details of iDRAC.IPv4Static.DNSFromDHCP Description Specifies if the DNS server IPv4 addresses should be assigned from the DHCP server on the network.
Write Privilege Configure iDRAC License Required iDRAC Express or iDRAC Enterprise Dependency None iDRAC.IPv6 To manage the IPv6 configuration properties of iDRAC, use the objects in this group. iDRAC.IPv6.Address1 (Read or Write) Table 587. Details of iDRAC.IPv6.Address 1 attribute Description iDRAC IPv6 Address. Legal Values Valid IPv6 Address Default Value Write Privilege Configure iDRAC License Required iDRAC Express or iDRAC Enterprise Dependency Cannot be set unless IPv6.
iDRAC.IPv6.Address4 (Read or Write) Table 590. Details of iDRAC.IPv6.Address 4 attribute Description iDRAC IPv6 fourth address. Legal Values Valid IPv6 Address Default Value Write Privilege Configure iDRAC License Required iDRAC Express or iDRAC Enterprise Dependency None iDRAC.IPv6.Address5 (Read or Write) Table 591. Details of iDRAC.IPv6.Address 5 attribute Description iDRAC IPv6 fifth address.
License Required iDRAC Express or iDRAC Enterprise Dependency None iDRAC.IPv6.Address8 (Read or Write) Table 594. Details of iDRAC.IPv6.Address8 attribute Description iDRAC IPv6 eighth address. Legal Values Valid IPv6 Address Default Value :: Write Privilege Configure iDRAC License Required iDRAC Express or iDRAC Enterprise Dependency None iDRAC.IPv6.Address9 (Read or Write) Table 595. Details of iDRAC.IPv6.Address9 attribute Description iDRAC IPv6 ninth address.
Legal Values Valid IPv6 Address Default Value :: Write Privilege Configure iDRAC License Required iDRAC Express or iDRAC Enterprise Dependency None iDRAC.IPv6.Address12 (Read or Write) Table 598. Details of iDRAC.IPv6.Address12 attribute Description iDRAC IPv6 twelfth address. Legal Values Valid IPv6 Address Default Value :: Write Privilege Configure iDRAC License Required iDRAC Express or iDRAC Enterprise Dependency None iDRAC.IPv6.Address13 (Read or Write) Table 599. Details of iDRAC.
iDRAC.IPv6.Address15 (Read or Write) Table 601. Details of iDRAC.IPv6.Address15 attribute Description iDRAC IPv6 fifteenth address. Legal Values Valid IPv6 Address Default Value :: Write Privilege Configure iDRAC License Required iDRAC Express or iDRAC Enterprise Dependency None iDRAC.IPv6.AutoConfig (Read or Write) Table 602. Details of iDRAC.IPv6.AutoConfig attribute Description Enables or disables the iDRAC IPv6 auto configuration option.
Write Privilege Configure iDRAC License Required iDRAC Express or iDRAC Enterprise Dependency Cannot be set unless IPv6.DNSFromDHCP6 is disabled. iDRAC.IPv6.DNSFromDHCP6 (Read or Write) Table 605. Details of iDRAC.IPv6.DNSFromDHCP6 attribute Description Specifies if the DNS Server addresses are obtained from DHCP or not.
iDRAC.IPv6.LinkLocalAddress (Read or Write) Table 608. Details of iDRAC.IPv6.LinkLocalAddress attribute Description iDRAC IPv6 Link Local Address. Legal Values Valid IPv6 Address Default Value :: Write Privilege Configure iDRAC License Required iDRAC Express or iDRAC Enterprise Dependency None iDRAC.IPv6.PrefixLength (Read or Write) Table 609. Details of iDRAC.IPv6.PrefixLength attribute Description Prefix length for the iDRAC IPv6 Address.
Write Privilege Configure iDRAC License Required iDRAC Express or iDRAC Enterprise Dependency None iDRAC.IPv6Static.DNS2 (Read or Write) Table 612. Details of iDRAC.IPv6Static.DNS2 attribute Description Statically configurable DNS Server 2. Legal Values Valid IPv6 Address Write Privilege Configure iDRAC License Required iDRAC Express or iDRAC Enterprise Dependency None iDRAC.IPv6Static.DNSFromDHCP6 (Read or Write) Table 613. Details of iDRAC.IPv6Static.
Legal Values Integral values: 1–128 Default Value 64 Write Privilege Configure iDRAC License Required iDRAC Express or iDRAC Enterprise Dependency None iDRAC.IPv6URL Use the objects in this group to manage the IPv6 static configuration properties of iDRAC. iDRAC.IPv6URL.URL (Read Only) Table 616. Details of iDRAC.IPv6URL.
Default Value Not Applicable Write Privilege Configure iDRAC and configure user License Required iDRAC Enterprise Dependency None iDRAC.LDAP.BindPassword (Write Only) Table 619. Details of iDRAC.LDAP.BindPassword attribute Description A bind password to use along with the bindDN. Legal Values String of up to 254 ASCII characters Default Value Not Applicable Write Privilege Configure iDRAC and configure user License Required iDRAC Enterprise Dependency None iDRAC.LDAP.
iDRAC.LDAP.GroupAttribute (Read or Write) Table 622. Details of iDRAC.LDAP.GroupAttribute attribute Description Specifies which LDAP attribute is used to check for group membership. Legal Values String of up to 128 ASCII characters Default Value Not Applicable Write Privilege Configure iDRAC and configure user License Required iDRAC Enterprise Dependency None iDRAC.LDAP.GroupAttributeIsDN (Read or Write) Table 623. Details of iDRAC.LDAP.
Default Value Not Applicable Write Privilege Configure iDRAC and configure user License Required iDRAC Enterprise Dependency None iDRAC.LDAP.Server (Read or Write) Table 626. Details of iDRAC.LDAP.Server attribute Description Configures the address of the LDAP Server. Legal Values String of up to 254 ASCII characters Default Value Not Applicable Write Privilege Configure iDRAC and configure user License Required iDRAC Enterprise Dependency None iDRAC.LDAP.
iDRAC.LDAPRoleGroup.Privilege(Read or Write) Table 629. Details of iiDRAC.LDAPRoleGroup.Privilege attribute Description A bit-mask defining the privileges associated with this particular group. Legal Values Integral values: 0–511 (0x1FF) Default Value 0 Write Privilege Configure iDRAC License Required iDRAC Enterprise Dependency None iDRAC.LocalSecurity To manage the ability to configure iDRAC, use the objects in this group. iDRAC.LocalSecurity.LocalConfigDisabled (Read or Write) Table 630.
iDRAC.Logging.SELOEMEventFilterEnable (Read or Write) Table 632. Details of iDRAC.Logging.SELOEMEventFilterEnable attribute Description Enables or disables the ability of Logging SEL Records with OEM. Legal Values • • Default Value 0 — Disabled Write Privilege Configure iDRAC 0 — Disabled 1 — Enabled License Required iDRAC Express or iDRAC Enterprise Dependency None iDRAC.NIC To configure the iDRAC NIC, use the object in this group.
iDRAC.NIC.AutoDetect (Read or Write) Table 634. Details of iDRAC.NIC.AutoDetect attribute Description Enables or disables auto detection feature of iDRAC. Legal Values • • Default Value 0 — Disabled Write Privilege Configure iDRAC 0 — Disabled 1 — Enabled License Required iDRAC Express or iDRAC Enterprise Dependency This object is writable only when NIC Selection is in shared mode. iDRAC.NIC.Autoneg (Read or Write) Table 635. Details of iDRAC.NIC.
Legal Values • • Default Value 0 — Disabled Write Privilege Configure iDRAC 0 — Disabled 1 — Enabled License Required iDRAC Express or iDRAC Enterprise Dependency Can be Enabled only if the following are enabled: • • IPv4.Enable and IPv4.DHCPEnable IPv6.Enable and IPv6.AutoConfig iDRAC.NIC.DNSDomainName (Read or Write) Table 638. Details of iDRAC.NIC.DNSDomainName attribute Description The DNS Domain Name.
License Required iDRAC Express or iDRAC Enterprise Dependency None iDRAC.NIC.DNSRegister (Read or Write) Table 641. Details of iDRAC.NIC.DNSRegister attribute Description Registers the iDRAC name with the DNS server. Legal Values • • Default value 0 — Disabled Write Privilege Configure iDRAC 0 — Disabled 1 — Enabled License Required iDRAC Express or iDRAC Enterprise Dependency Can be Enabled only if DNSRacName is set. iDRAC.NIC.Duplex (Read or Write) Table 642. Details of iDRAC.NIC.
iDRAC.NIC.Failover (Read or Write) Table 644. Details of iDRAC.NIC.Failover attribute Description Enables or disables failover for iDRAC to switch from shared to dedicated. Legal Values • • • • • • Default Value 0 — None Write Privilege Configure iDRAC 0 — None 2 — LOM1 3 — LOM2 4 — LOM3 5 — LOM4 6 — All License Required iDRAC Express or iDRAC Enterprise Dependency Possible Values depend on current NICSelection settings. iDRAC.NIC.MACAddress (Read or Write) Table 645. Details of iDRAC.NIC.
iDRAC.NIC.Selection (Read or Write) Table 647. Details of iDRAC.NIC.Selection attribute Description Specifies the current mode of operation for the iDRAC network interface controller. Legal Values • • • • • Default Value 1 — Dedicated Write Privilege Configure iDRAC 1 — Dedicated 2 — LOM1 3 — LOM2 4 — LOM3 5 — LOM4 License Required iDRAC Express or iDRAC Enterprise Dependency None NOTE: Values for the platforms with single LOM port are, 1 — Dedicated and 2 — LOM1. iDRAC.NIC.
Default Value 1 — 100 Write Privilege Configure iDRAC License Required iDRAC Express or iDRAC Enterprise Dependency Cannot change NIC Speed unless AutoNeg is set to disabled. iDRAC.NIC.TopologyLldp (Read or Write) Table 650. Details of iDRAC.NIC.TopologyLldp attribute Description Enables or disables the LLDP Protocol Legal Values • • Default Value 0—Disable Write Privilege Configure iDRAC Enable-1 Disable-0 License Required iDRAC Express or iDRAC Enterprise Dependency None iDRAC.NIC.
Dependency None iDRAC.NIC.VLanPort (Read or Write) Table 653. Details of iDRAC.NIC.VLanPort attribute Description Enables or disables the VLAN switch of the iDRAC. Legal Values • • • Default Value 0 — Both Write Privilege Configure iDRAC 1 — Dedicated ports only 2 — LOM ports only 0 — Both the ports License Required RACADM Dependency None iDRAC.NIC.VLanPriority (Read Only) Table 654. Details of iDRAC.NIC.
iDRAC.NICStatic.DNSDomainName (Read or Write) Table 656. Details of iDRAC.NICStatic.DNSDomainName attribute Description The DNS Domain Name. Legal Values • • Default Value Not Applicable Write Privilege Configure iDRAC 0 — Disabled 1 — Enabled License Required iDRAC Express or iDRAC Enterprise Dependency None iDRAC.NTPConfigGroup To configure the properties of NTP server, use the objects in this group. iDRAC.NTPConfigGroup.NTP1 (Read or Write) Table 657. Details of iDRAC.NTPConfigGroup.
Legal Values String of up to 254 ASCII characters. Default Value Not Applicable Write Privilege Configure iDRAC License Required iDRAC Express or iDRAC Enterprise Dependency None iDRAC.NTPConfigGroup.NTPEnable (Read or Write) Table 660. Details of iDRAC.NTPConfigGroup.NTPEnable attribute Description On iDRAC, enable or disable NTP server access to iDRAC.
Default Value 0 — Disabled Write Privilege Configure iDRAC License Required iDRAC Express or iDRAC Enterprise Dependency Can be set only if iDRAC.OS-BMC.PTCapability is set to Capable. iDRAC.OS-BMC.OSIpAddress (Read or Write) Table 663. Details of iDRAC.OS-BMC.OSIpAddress Description IPv4 address of the host Operating System. Legal Values Valid IPv4 Address Default Value 0.0.0.0 Write Privilege Configure iDRAC License Required iDRAC Express or iDRAC Enterprise Dependency None iDRAC.OS-BMC.
Dependency None iDRAC.OS-BMC.UsbNicIpAddress (Read or Write) Table 666. Details of iDRAC.OS-BMC.UsbNicIpAddress Description Displays the USB NIC IP address. Legal Values Valid IPv4 address Default Value 169.168.0 Write Privilege Configure iDRAC License Required iDRAC Express or iDRAC Enterprise Dependency None iDRAC.Racadm To manage Remote RACADM connection settings, use the object in this group. iDRAC.Racadm.Enable (Read or Write) Table 667. Details of iDRAC.Racadm.
iDRAC.Redfish The objects in this group provide configuration parameters for the Redfish interface to iDRAC. iDRAC.Redfish.Enable (Read or Write) Table 669. Details of iDRAC.Redfish.Enable Description Enables or disables Redfish service on iDRAC. Legal Values • • Default Value 1 — Enabled Write Privilege Configure iDRAC 0 — Disabled 1 — Enabled License Required RACADM Dependency None iDRAC.Redfisheventing The objects in this group provide information on Redfish events. iDRAC.Redfisheventing.
License Required RACADM Dependency None iDRAC.Redfisheventing.IgnoreCertificateErrors (Read Only) Table 672. Details of iDRAC.Redfisheventing.IgnoreCertificateErrors Description Enables or disables Ignorance of Certificate Errors notifications. Legal Values • • Default Value 0 — Disabled Write Privilege Configure iDRAC 0 — Disabled 1 — Enabled License Required None Dependency None iDRAC.RemoteHosts Use the objects in this group to manage the properties for configuration of the SMTP server.
iDRAC.RFS To configure Remote file share access to iDRAC, use the object in this group. NOTE: To perform the complete workflow for RFS and set attributes, see the remoteimage section. iDRAC.RFS.IgnoreCertWarning (Read or Write) Table 675. Details of idrac.rfs.ignoreCertWarning attribute Description To ignore certificate warning message. Legal Values • • Default Value 1-Show error Write Privilege Not Applicable 0- Ignore 1- Show error License Required RACADM Dependency None iDRAC.RFS.
iDRAC.RSM.RSMCapability (Read Only) Table 677. Details of iDRAC.RSM.RSMCapability Description Specifies the status of RSM capability. Legal Values • • Default Value 0 — Disabled License Required iDRAC Express or iDRAC Enterprise Dependency None 0 — Disabled 1 — Enabled iDRAC.RSM.RSMSetting (Read Only) Table 678. Details of iDRAC.RSM.RSMSetting Description Specifies the status of RSM setting.
iDRAC.Security.CsrCommonName (Read or Write) Table 679. Details of iDRAC.Security.CsrCommonName Description Specifies the CSR Common Name (CN) that must be an IP as given in the certificate. Legal Values String of up to 254 ASCII characters Default Value Not Applicable Write Privilege Configure iDRAC License Required iDRAC Express or iDRAC Enterprise Dependency None iDRAC.Security.CsrCountryCode (Read or Write) Table 680. Details of iDRAC.Security.
Write Privilege Configure iDRAC License Required iDRAC Express or iDRAC Enterprise Dependency None iDRAC.Security.CsrLocalityName (Read or Write) Table 683. Details of iDRAC.Security.CsrLocalityName Description Specifies the CSR Locality (L). Legal Values String of up to 254 ASCII characters Default Value Not Applicable Write Privilege Configure iDRAC License Required iDRAC Express or iDRAC Enterprise Dependency None iDRAC.Security.CsrOrganizationName (Read or Write) Table 684.
iDRAC.Security.CsrStateName (Read or Write) Table 686. Details of iDRAC.Security.CsrStateName Description Specifies the CSR State Name (S). Legal Values String of up to 254 ASCII characters Default Value Not Applicable Write Privilege Configure iDRAC License Required iDRAC Express or iDRAC Enterprise Dependency None iDRAC.Security.CsrSubjectAltName (Read or Write) Table 687. Details of iDRAC.Security.CsrSubjectAltName attribute Description Specifies the CSR subject alternative name.
iDRAC.Serial The objects in this group provide configuration parameters for the serial interface of iDRAC. NOTE: This is supported only for rack and tower systems. iDRAC.Serial.BaudRate (Read or Write) Table 689. Details of iDRAC.Serial.BaudRate Description Sets the Baud rate on the iDRAC serial port. Legal Values • • • • Default Value 115200 Write Privilege Configure iDRAC 9600 19200 57600 115200 License Required iDRAC Express or iDRAC Enterprise Dependency None iDRAC.Serial.
iDRAC.Serial.HistorySize (Read or Write) Table 692. Details of iDRAC.Serial.HistorySize Description Specifies the maximum size of the serial history buffer. Legal Values Integral values from 0 to 8192. Default Value 8192 Write Privilege Configure iDRAC License Required iDRAC Express or iDRAC Enterprise Dependency None iDRAC.Serial.IdleTimeout (Read or Write) Table 693. Details of iDRAC.Serial.
iDRAC.SerialRedirection.Enable (Read or Write) Table 695. Details of iDRAC.SerialRedirection.Enable Description Enables or disables the console for COM2 port redirection. Legal Values • • Default Value 1 — Enabled Write Privilege Configure iDRAC 0 — Disabled 1 — Enabled License Required iDRAC Express or iDRAC Enterprise Dependency None iDRAC.SerialRedirection.QuitKey (Read or Write) Table 696. Details of iDRAC.SerialRedirection.
iDRAC.serverboot.FirstBootDevice (Read or Write) Table 698. Details of iDRAC.serverboot.FirstBootDevice Description Configures the first boot device.
License Required RACADM Dependency None iDRAC.ServiceModule.HostSNMPAlert (Read or Write) Description Specifies the destination port for remote hosts. Legal Values • • Default Value 0 Write Privilege Configure iDRAC License Required iDRAC Basic Dependancy None Disabled-0 Enabled-1 iDRAC.ServiceModule.HostSNMPGet Table 700. Details of iDRAC.ServiceModule.HostSNMPGet attribute Description Enable or disable SNMP get via host OS.
• 1 — Enabled Default Value 0 — Disabled Write Privilege Configure iDRAC License Required iDRAC Express or iDRAC Enterprise Dependency If OpenManage Server Administrator is available, then the attribute is automatically set to ‘Disabled’. iDRAC.ServiceModule.OMSAPresence (Read Only) Table 703. Details of iDRAC.ServiceModule.OMSAPresence Description Verifies if OMSA is present.
iDRAC.ServiceModule.ServiceModuleState (Read or Write) Table 706. Details of iDRAC.ServiceModule.ServiceModuleState Description Indicates the status of Service Module process on the host operating system. Legal Values • • Default Value 1 — Enabled Write Privilege Configure iDRAC 0 — Disabled 1 — Enabled License Required iDRAC Express or iDRAC Enterprise Dependency None iDRAC.ServiceModule.ServiceModuleVersion (Read) Table 707. Details of iDRAC.ServiceModule.
License Required iDRAC Express or iDRAC Enterprise Dependency If the iDRAC.ServiceModule.WatchdogState object is 'Disabled', then the value cannot be set. iDRAC.ServiceModule.WatchdogResetTime (Read and Write) Table 709. Details of iDRAC.ServiceModule.WatchdogResetTime Description Configures the system reset time (unit in seconds) on watchdog alert.
iDRAC.SmartCard.SmartCardCRLEnable (Read or Write) Table 711. Details of iDRAC.SmartCard.SmartCardCRLEnable Description Enables or disables the Certificate Revocation List (CRL). Legal Values • • Default Value Not Applicable Write Privilege Configure iDRAC and configure user 0 — Disabled 1 — Enabled License Required iDRAC Enterprise Dependency To log on, enable Smart Card. iDRAC.SmartCard.SmartCardLogonEnable (Read or Write) Table 712. Details of iDRAC.SmartCard.
iDRAC.SNMP.AgentEnable (Read or Write) Table 714. Details of iDRAC.SNMP.AgentEnable Description Enables or disables the SNMP Agent on the iDRAC. Legal Values • • Default Value 1 — Enabled Write Privilege Configure iDRAC 0 — Disabled 1 — Enabled License Required iDRAC Express or iDRAC Enterprise Dependency None iDRAC.SNMP.AlertPort (Read or Write) Table 715. Details of iDRAC.SNMP.AlertPort Description Specifies the SNMP alert port for traps.
License Required iDRAC Express or iDRAC Enterprise Dependency None iDRAC.SNMP.TrapFormat (Read or Write) Table 718. Details of iDRAC.SNMP.TrapFormat Description Specifies the SNMP format. Legal Values • • • Default Value 0 — SNMPv1 Write Privilege Configure iDRAC 0 — SNMPv1 1 — SNMPv2 2 — SNMPv3 License Required iDRAC Express or iDRAC Enterprise Dependency None iDRAC.SNMP.Alert The objects in this group configures the SNMP alert settings. This group is indexed from 1 to 8. iDRAC.SNMP.Alert.
License Required None Dependency None iDRAC.SNMP.Alert.SNMPv3UserID (Read Only) Table 721. Details of iDRAC.SNMP.Alert.SNMPv3UserID Description Indicates the index of the user to which this alert is configured. Legal Values Integral values: 2–16 Default Value Not Applicable Write Privilege Configure iDRAC License Required iDRAC Express Dependency None iDRAC.SNMP.Alert.SNMPv3Username (Read or Write) Table 722. Details of iDRAC.SNMP.Alert.
iDRAC.SSH.Port (Read or Write) Table 724. Details of iDRAC.SSH.Port Description Specifies the port number for the iDRAC SSH interface. Legal Values Integral values: 1–65535 Default Value 22 Write Privilege Configure iDRAC License Required iDRAC Express or iDRAC Enterprise Dependency None iDRAC.SSH.Timeout (Read or Write) Table 725. Details of iDRAC.SSH.Timeout Description Defines the secure shell idle timeout.
Legal Values 0-No 1-Yes Default Value 0-No License Required RACADM Dependency None iDRAC.SupportAssist.HostOSProxyPassword Table 728. Details of iDRAC.SupportAssist.HostOSProxyPassword Description Host OS proxy password. Legal Values String of 0 to 64 characters length Default Value NA License Required RACADM Dependency HostOSProxyConfigured should be 1=Yes iDRAC.SupportAssist.HostOSProxyPort Table 729. Details of iDRAC.SupportAssist.HostOSProxyPort Description Host OS proxy port.
iDRAC.SysLog.Port (Read or Write) Table 731. Details of iDRAC.SysLog.Port Description Remote syslog port number. Legal Values Integral values: 1–65535 Default Value 514 Write Privilege Configure iDRAC License Required iDRAC Enterprise Dependency None iDRAC.SysLog.PowerLogEnable (Read or Write) Table 732. Details of iDRAC.SysLog.PowerLogEnable Description Enables or disables the Power Log feature.
Write Privilege Configure iDRAC License Required iDRAC Enterprise Dependency None iDRAC.SysLog.Server2 (Read or Write) Table 735. Details of iDRAC.SysLog.Server2 Description Name of remote syslog server 2. Legal Values String of up to 63 ACSII characters Default Value Not Applicable Write Privilege Configure iDRAC License Required iDRAC Enterprise Dependency None iDRAC.SysLog.Server3 (Read or Write) Table 736. Details of iDRAC.SysLog.Server3 Description Name of remote syslog server 3.
iDRAC.Telnet.Enable (Read or Write) Table 738. Details of iDRAC.Telnet.Enable Description Enables or disables Telnet. Legal Values • • Default Value 0 — Disabled Write Privilege Configure iDRAC 0 — Disabled 1 — Enabled License Required iDRAC Express or iDRAC Enterprise Dependency None iDRAC.Telnet.Port (Read or Write) Table 739. Details of iDRAC.Telnet.Port Description Specifies the port number for the iDRAC Telnet interface.
Legal Values Valid time zone string of up to 32 ASCII characters For example: US/Central Default Value CST6CDT Write Privilege Configure iDRAC License Required iDRAC Express or iDRAC Enterprise Dependency None iDRAC.Time.TimeZoneOffset (Read or Write) Table 742. Details of iDRAC.Time.TimeZoneOffset Description Specifies the time zone offset (in minutes) from Greenwich Mean Time (GMT) or Coordinated Universal Time (UTC) to use for the iDRAC Time.
iDRAC.Update.FwUpdateIPAddr (Read or Write) Table 744. Details of iDRAC.Update.FwUpdateIPAddr Description Specifies the TFTP server address to be used for iDRAC firmware update operations. Legal Values Valid IPv4, IPv6, or FQDN address of the TFTP server Default Value Not Applicable Write Privilege Configure iDRAC License Required iDRAC Express or iDRAC Enterprise Dependency None iDRAC.Update.FwUpdatePath (Read or Write) Table 745. Details of iDRAC.Update.
iDRAC.USB.ConfigurationXML (Read or Write) Table 747. Details of iDRAC.USB.ConfigurationXML attribute Description Manages the configuration xml feature using the front panel USB. Legal Values • • • Default Value Enabled while server has default credential settings only. Write Privilege Server Control Disabled Enabled while server has default credential settings only Enabled License Required iDRAC Express and iDRAC Enterprise Dependency Not Applicable iDRAC.USB.
Dependency None iDRAC.UserDomain The objects in this group enable you to manage the Active Directory user domain names. This group is indexed from 1 to 40. iDRAC.UserDomain.Name (Read or Write) Table 750. Details of iDRAC.UserDomain.Name attribute Description Specifies the Active Directory user domain name for a given index.
Default Value 15 — No access Write Privilege Configure iDRAC License Required iDRAC Express or iDRAC Enterprise Dependency Both user name and password must be configured prior to setting this object. iDRAC.Users.IpmiSerialPrivilege (Read or Write) Table 753. Details of iDRAC.Users.IpmiSerialPrivilege attribute Description Specifies the maximum IPMI Serial privilege.
iDRAC.Users.SHA256Password (Read or Write) Table 756. Details of iDRAC.Users.SHA256Password attribute Description Indicates the SHA256 hash of the password. Legal Values String of 64 characters Default Value Not Applicable Write Privilege Configure iDRAC and Configure User License Required iDRAC Express Dependency User name must be configured prior to setting this object. iDRAC.Users.SHA256PasswordSalt (Read or Write) Table 757. Details of iDRAC.Users.
iDRAC.Users.SNMPv3AuthenticationType (Read or Write) Table 760. Details of iDRAC.Users.SNMPv3AuthenticationType attribute Description Configure SNMPv3 authentication protocol type. Legal Values • • • Default Value 2 — SHA Write Privilege Configure iDRAC and Configure User 0 — None 1 — MD5 2 — SHA License Required iDRAC Express or iDRAC Enterprise Dependency None iDRAC.Users.SNMPv3Enable (Read or Write) Table 761. Details of iDRAC.Users.
iDRAC.Users.SolEnable (Read or Write) Table 763. Details of iDRAC.Users.SolEnable attribute Description Enables or Disables SOL for the user. Legal Values • • Default Value 0 — Disabled Write Privilege Configure iDRAC and Configure User 0 — Disabled 1 — Enabled License Required iDRAC Express or iDRAC Enterprise Dependency Both username and password must be configured prior to sets. iDRAC.Users.UserName (Read or Write) Table 764. Details of iDRAC.Users.
iDRAC.vflashpartition.AttachState (Read or Write) Table 766. Details of iDRAC.vflashpartition.AttachState attribute Description Specifies if the vFlash SD partition is attached or detached. Legal Values • • Default value 0 — Detached Write Privilege Login and configure iDRAC 1 — Attached 0 — Detached License Required iDRAC Enterprise Dependency vFlash SD card must be enabled. Partition at the specified index must be created. iDRAC.vflashpartition.EmulationType (Read or Write) Table 767.
Write Privilege Login and configure iDRAC License Required iDRAC Enterprise Dependency vFlash SD card must be enabled. Partition at the specified index must be created. iDRAC.vflashpartition.VolumeLabel (Read or Write) Table 770. Details of iDRAC.vflashpartition.VolumeLabel attribute Description Specifies the label assigned to the partition during the vFlash SD partition creation. Legal Values String of up to six characters.
Legal Values • • • • Default value OK Write Privilege Login and configure iDRAC OK Warning Critical Unknown License Required iDRAC Enterprise Dependency vFlash SD card must be enabled. iDRAC.vflashsd.Initialized (Read or Write) Table 774. Details of attribute Description Specifies if the vFlash SD card is initialized or not.
iDRAC.vflashsd.WriteProtect (Read or Write) Table 777. Details of iDRAC.vflashsd.WriteProtect attribute Description Displays if the physical write protect is enabled or disabled on the vFlash SD card. Legal Values • • Default value None Write Privilege Login and configure iDRAC 0 — Disabled 1 — Enabled License Required iDRAC Enterprise Dependency vFlash SD card must be enabled. iDRAC.VirtualConsole The objects in this group enable you to manage virtual console configuration parameters of iDRAC.
iDRAC.VirtualConsole.Enable (Read or Write) Table 780. Details of iDRAC.VirtualConsole.Enable attribute Description Enables or disables the Virtual Console. Legal Values • • Default Value 1 — Enabled Write Privilege Configure iDRAC 0 — Disabled 1 — Enabled License Required iDRAC Express (For Blades) or iDRAC Enterprise Dependency None iDRAC.VirtualConsole.EncryptEnable (Read or Write) Table 781. Details of iDRAC.VirtualConsole.
Default Value 4 Write Privilege Configure iDRAC License Required iDRAC Express (For Blades) or iDRAC Enterprise Dependency None iDRAC.VirtualConsole.PluginType (Read or Write) Table 784. Details of iDRAC.VirtualConsole.PluginType attribute Description Specifies the plugin type to use while running virtual console from the browser.
iDRAC.VirtualMedia The objects in this group enable you to manage virtual media configuration parameters of iDRAC. iDRAC.VirtualMedia.Attached (Read or Write) Table 787. Details of iDRAC.VirtualMedia.Attached attribute Description Used to attach virtual devices to the system using the USB bus. Legal Values • • • Default Value 2 — AutoAttach Write Privilege Virtual Media 0 — Detached 1 — Attached 2 — AutoAttach License Required iDRAC Express (For Blades) or iDRAC Enterprise Dependency None iDRAC.
iDRAC.VirtualMedia.EncryptEnable (Read or Write) Table 790. Details of iDRAC.VirtualMedia.EncryptEnable attribute Description Specifies the Virtual Media encryption Legal Values • • Default Value 0—Disabled Write Privilege Virtual Media 0—Disabled 1—Enabled License Required iDRAC Express (For Blades) or iDRAC Enterprise Dependency None iDRAC.VirtualMedia.FloppyEmulation (Read or Write) Table 791. Details of iDRAC.VirtualMedia.
Legal Values • • Default value 0 — Disabled Write Privilege Login or configure iDRAC 0 — Disabled 1 — Enabled License Required iDRAC Enterprise Dependency None iDRAC.VNCServer.LowerEncryptionBitLength (Read or Write) Table 793. Details of iDRAC.VNCServer.LowerEncryptionBitLength attribute Description Lower encryption bit length.
iDRAC.VNCServer.SSLEncryptionBitLength (Read or Write) Table 796. Details of iDRAC.VNCServer.SSLEncryptionBitLength attribute Description Indicates the VNC server encryption state. Legal Values • • • • • Default value 0 — Disabled Write Privilege iDRAC Configure License Required iDRAC Enterprise Dependency None 0 — Disabled 1 — Auto negotiate 2— 128 bit or higher 3— 168 bit or higher 4— 256 bit or higher iDRAC.VNCServer.Timeout (Read or Write) Table 797. Details of iDRAC.VNCServer.
Dependency None iDRAC.WebServer.Enable (Read or Write) Table 799. Details of iDRAC.WebServer.Enable attribute Description Enables or disables iDRAC WebServer. Legal Values • • Default Value 1 — Enabled Write Privilege Configure iDRAC 0 — Disabled 1 — Enabled License Required iDRAC Express or iDRAC Enterprise Dependency None iDRAC.WebServer.HttpPort (Read or Write) Table 800. Details of iDRAC.WebServer.
Legal Values • • Default Value 1 — Enabled Write Privilege Configure iDRAC 1 — Enabled 0 — Disabled License Required iDRAC Express or iDRAC Enterprise Dependency None iDRAC.WebServer.LowerEncryptionBitLength (Read or Write) Table 803. Details of iDRAC.WebServer.LowerEncryptionBitLength attribute Description Lower Encryption Bit Length.
License Required iDRAC Express or iDRAC Enterprise Dependency None iDRAC.webServer.TitleBarOption (Read or Write) Table 805. Details of iDRAC.webServer.TitleBarOption attribute Description Specifies what to display in the title bar. Legal Values • • • • • • Default Value Null Write Privilege Configure iDRAC 0- Auto 1- DNS RAC Name 2- IP Address 3- Service Tag 4- System Host Name 5- Custom License Required iDRAC Express or iDRAC Enterprise Dependency None iDRAC.webServer.
iDRAC.WebServer.TLSProtocol (Read or Write) Table 808. Details of iDRAC.WebServer.TLSProtocol attribute Description Defines the TLS protocol support. Legal Values • • • Default Value 1 — TLS 1.1 and higher Write Privilege Configure iDRAC 0 — TLS 1.0 and higher 1 — TLS 1.1 and higher 2 — TLS 1.2 only License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.BiosBootSettings You can manage the BIOS start settings using the objects in this group. BIOS.BiosBootSettings.
BIOS.BiosBootSettings.BootSeqRetry (Read or Write) Table 811. Details of BIOS.BiosBootSettings.BootSeqRetry attribute Description Enables or disables the boot sequence retry feature. Legal Values Enabled Disabled Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.BiosBootSettings.HddFailover (Read or Write) Table 812. Details of BIOS.BiosBootSettings.
Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Read Only if Boot mode is set to BIOS BIOS.BiosBootSettings.SetBootOrderDis (Read or Write) Description The SetBootOrderDis fields specify a list of Fqdds representing the boot option Disabled to be applied on the next boot.
BIOS.BiosBootSettings.SetLegacyHddOrderFqddn (Read or Write) Table 816. Details of BIOS.BiosBootSettings.SetLegacyHddOrderFqddn attribute Description Specifies a list of FQDDs that has the legacy HDD list to apply on the next boot. In the attribute SetLegacyHddOrderFqdd, the value of n can be 1 to 16 Legal Values String of UEFI boot devices Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.
BIOS.IntegratedDevices.CurrentEmbVideoState (Read or Write) Description Read-only. Indicates the current state of the Embedded Video Controller. If the Embedded Video Controller is the only display capability in the system (that is, no add-in graphics card is installed), then the Embedded Video Controller is automatically used as the primary display even if the Embedded Video Controller setting is Disabled.
Legal Values • • • • Default Value Not Applicable Write Privilege Server Control Enabled EnabledPxe EnablediScsi Disabled License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.IntegratedDevices.EmbNic3 (Read or Write) Table 822. Details of BIOS.IntegratedDevices.EmbNic3 attribute Description Enables or disables the operating system interface of the embedded NIC3.
• • • EnabledPxe EnablediScsi Disabled Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.IntegratedDevices.EmbVideo (Read or Write) Table 825. Details of IOS.IntegratedDevices.EmbVideo attribute Description Enables or disables the BIOS support for the embedded video controller.
Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.IntegratedDevices.IntegratedNetwork2 (Read or Write) Table 828. Details of BIOS.IntegratedDevices.IntegratedNetwork2 attribute Description Enables or disables the integrated network card 2. Legal Values • • Default Value Not Applicable Write Privilege Server Control Enabled DisabledOS License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.IntegratedDevices.
BIOS.IntegratedDevices.InternalSdCard (Read or Write) Table 831. Details of BIOS.IntegratedDevices.InternalSdCard attribute Description Enables or disables the internal SD Card port. Legal Values • • Default Value Not Applicable Write Privilege Server Control On Off License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.IntegratedDevices.InternalSdCardRedundancy (Read or Write) Table 832. Details of BIOS.IntegratedDevices.
Legal Values • • Default Value Not Applicable Write Privilege Server Control On Off License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.IntegratedDevices.InternalUsb2 (Read or Write) Table 835. Details of BIOS.IntegratedDevices.InternalUsb2 attribute Description Enables or disables the internal USB port 2. Legal Values • • Default Value Not Applicable Write Privilege Server Control On Off License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.
Dependency None BIOS.IntegratedDevices.IONonPostedPrefetch Table 838. Details of BIOS.IntegratedDevices.IONonPostedPrefetch attribute Description Enables or disables the PCI IO non-posted pre-fetch mode to control the PCIe throughput. When this option is enabled, the read operation from the PCI devices are optimized. However, performance is reduced for write operation from the PCI devices.
BIOS.IntegratedDevices.SriovGlobalEnable (Read or Write) Table 841. Details of BIOS.IntegratedDevices.SriovGlobalEnable attribute Description Enables or disables BIOS configuration of Single Root I/O Virtualization (SR-IOV) devices. Legal Values • • Default Value Not Applicable Write Privilege Server Control Enabled Disabled License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.IntegratedDevices.Usb3Setting (Read or Write) Description Controls USB 3.0 support.
BIOS.MemSettings To manage memory-related configuration settings, use the objects in this group. BIOS.MemSettings.CorrEccSmi (Read or Write) Description Allows the system to log ECC corrected DRAM errors into the SEL log. Logging these rare errors can help identify marginal components; however the system will pause for a few milliseconds after an error while the log entry is created. Latency conscious customers may wish to disable the feature.
BIOS.MemSettings.MemOptimizer (Read or Write) Table 845. Details of BIOS.MemSettings.MemOptimizer attribute Description Configure the memory optimizer setting. Legal Values • • Default Value Not Applicable Write Privilege Server Control Enabled Disabled License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.MemSettings.MemOpVoltage (Read Only) Table 846. Details of BIOS.MemSettings.MemOpVoltage attribute Description Operating voltage of memory.
• Disabled Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.MemSettings.RedundantMem (Read or Write) Table 849. Details of BIOS.MemSettings.RedundantMem attribute Description Enables or disables the redundant memory feature. Legal Values • • • • • • Write Privilege Server Control Disabled Spare Mirror IntraNodeMirror DimmSpare Dddc License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.
Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.MemSettings.Serialdbgout (Read or Write) Table 852. Details of BIOS.MemSettings.Serialdbgout attribute Description Enables or disables the Serial Debug Out option. Legal Values • • Default Value Not Applicable Enabled Disabled License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.MemSettings.SnoopFilter (Read or Write) Table 853. Details of BIOS.MemSettings.
Dependency Not applicable BIOS.MemSettings.SysMemSize (Read or Write) Table 854. Details of BIOS.MemSettings.SysMemSize attribute Description Indicates the current amount of main memory in the system. Legal Values None Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.MemSettings.SysMemSpeed (Read or Write) Table 855. Details of BIOS.MemSettings.
Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.MemSettings.VideoMem (Read or Write) Table 858. Details of BIOS.MemSettings.VideoMem attribute Description Indicates the total amount of video memory available to the embedded video controller. Legal Values None Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.
Dependency None BIOS.MiscSettings.InSystemCharacterization (Read or Write) Table 861. Details of BIOS.MiscSettings.InSystemCharacterization attribute Description The ratio of power and performance of a system is optimized by ISC when it is enabled. Legal Values • • • Default Value Not Applicable Enabled FastBoot Disabled License Required RACADM Dependency None BIOS.MiscSettings.NumLock (Read or Write) Table 862. Details of BIOS.MiscSettings.
BIOS.MiscSettings.SystemUefiShell (Read or Write) Table 864. Details of BIOS.MiscSettings.SystemUefiShell attribute Description Enables or disables the System UEFI Shell as a UEFI boot option choice. Legal Values • • Default Value Not Applicable Write Privilege Server Control Enabled Disabled License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.MiscSettings.SysMgmtNVByte1 (Read or Write) Table 865. Details of attribute Description Indicates the system management NVRAM byte 1.
BIOS.MiscSettings.ForceInt10 (Read or Write) Table 868. Details of BIOS.MiscSettings.ForceInt10 attribute Description Specifies if the system BIOS will load the legacy video (INT 10h) option ROM from the video controller. Legal Values • • Default Value Not Applicable Write Privilege Server Control Enabled Disabled License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.NetworkSettings The objects in this group manage the iSCSI devices. BIOS.NetworkSettings.
NOTE: On a Dell 13th generation of PowerEdge server, to set the value from OneTimeBootMode to OneTimeUefiBootSeq, you must boot the server in UEFI mode. BIOS.OneTimeBoot.OneTimeBootSeqDev (Read or Write) Table 871. Details of BIOS.OneTimeBoot.OneTimeBootSeqDev attribute Description Configure the one time boot sequence device in BIOS.
BIOS.OneTimeBoot.OneTimeUefiBootSeqDev (Read or Write) Table 874. Details of BIOS.OneTimeBoot.OneTimeUefiBootSeqDev attribute Description Configure the one time UEFI Boot Sequence device. Legal Values NIC or Optical Device list Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Read Only if OneTimeBootMode is not set to OneTimeUefiBootSeq BIOS.ProcSettings To configure the processor settings, use the objects in this group.
BIOS.ProcSettings.DcuIpPrefetcher (Read or Write) Table 877. Details of BIOS.ProcSettings.DcuIpPrefetcher attribute Description Enables or disables Data Cache Unit (DCU) IP Prefetcher. Legal Values • • Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency None Enabled Disabled BIOS.ProcSettings.DcuStreamerPrefetcher (Read or Write) Table 878. Details of BIOS.ProcSettings.
BIOS.ProcSettings.DynamicCoreAllocation (Read or Write) Table 880. Details of BIOS.ProcSettings.DynamicCoreAllocation attribute Description Enables or disables the operating system capability to set the logical processors in idle state which helps to reduce power consumption. Legal Values • • Default Value Not Applicable Write Privilege Server Control Enabled Disabled License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.ProcSettings.LogicalProc (Read or Write) Table 881.
Legal Values None Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.ProcSettings.Proc1ControlledTurbo (Read or Write) Table 884. Details of BIOS.ProcSettings.Proc1ControlledTurbo attribute Description Controls the turbo engagement. NOTE: You can enable this option only when System Profile is set to Performance.
Dependency None BIOS.ProcSettings.Proc1L3Cache (Read or Write) Table 887. Details of BIOS.ProcSettings.Proc1L3Cache attribute Description Amount of memory in the corresponding processor cache. Legal Values None Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.ProcSettings.Proc1NumCores (Read or Write) Table 888. Details of BIOS.ProcSettings.
Legal Values • • • • • Default Value Not Applicable Write Privilege Server Control Disabled ControlledTurboLimit ControlledTurboLimitMinus1 ControlledTurboLimitMinus2 ControlledTurboLimitMinus3 License Required iDRAC Express or iDRAC Enterprise Dependency Not Applicable BIOS.Procsettings.Proc2Cores Table 891. Details of BIOS.Procsettings.Proc2Cores attribute Description Controls the number of enabled cores in each processor.
Dependency None BIOS.ProcSettings.Proc2L3Cache (Read or Write) Table 894. Details of BIOS.ProcSettings.Proc2L3Cache attribute Description Amount of memory in the corresponding processor cache. Legal Values None Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.ProcSettings.Proc2NumCores (Read or Write) Table 895. Details of BIOS.ProcSettings.
Legal Values • • • • • Default Value Not Applicable Write Privilege Server Control Disabled ControlledTurboLimit ControlledTurboLimitMinus1 ControlledTurboLimitMinus2 ControlledTurboLimitMinus3 License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.Procsettings.Proc3Cores Table 898. Details of BIOS.Procsettings.Proc3Cores attribute Description Controls the number of enabled cores in each processor.
Dependency None BIOS.ProcSettings.Proc3L3Cache (Read or Write) Table 901. Details of BIOS.ProcSettings.Proc3L3Cache attribute Description Amount of memory in the corresponding processor cache. Legal Values None Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.ProcSettings.Proc3NumCores (Read or Write) Table 902. Details of BIOS.ProcSettings.
Legal Values • • • • • Default Value Not Applicable Write Privilege Server Control Disabled ControlledTurboLimit ControlledTurboLimitMinus1 ControlledTurboLimitMinus2 ControlledTurboLimitMinus4 License Required iDRAC Express or iDRAC Enterprise Dependency Not Applicable BIOS.Procsettings.Proc4Cores Table 905. Details of BIOS.Procsettings.Proc4Cores attribute Description Controls the number of enabled cores in each processor.
Dependency None BIOS.ProcSettings.Proc4L3Cache (Read or Write) Table 908. Details of BIOS.ProcSettings.Proc4L3Cache attribute Description Amount of memory in the corresponding processor cache. Legal Values None Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.ProcSettings.Proc4NumCores (Read or Write) Table 909. Details of BIOS.ProcSettings.
Legal Values • • Default Value Not Applicable Write Privilege Server Control Enabled Disabled License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.ProcSettings.ProcBusSpeed (Read or Write) Table 912. Details of BIOS.ProcSettings.ProcBusSpeed attribute Description Bus speed of the processor. Legal Values None Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.ProcSettings.
• • • 12 14 16 Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.ProcSettings.ProcCoreSpeed (Read or Write) Table 915. Details of vattribute Description Clock speed of the processor. Legal Values None Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.ProcSettings.ProcDramPrefetcher (Read or Write) Table 916. Details of BIOS.
License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.ProcSettings.ProcHpcMode (Read or Write) Table 918. Details of BIOS.ProcSettings.ProcHpcMode attribute Description Configure processor's HPC mode. Legal Values • • Default Value Not Applicable Write Privilege Server Control Enabled Disabled License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.ProcSettings.ProcHtAssist (Read or Write) Table 919. Details of BIOS.ProcSettings.
BIOS.ProcSettings.ProcHyperTransport (Read or Write) Table 921. Details of BIOS.ProcSettings.ProcHyperTransport attribute Description Specifies the supported HyperTransport I/O Link Specification. Legal Values • • Default Value Not Applicable Write Privilege Server Control HT1 HT3 License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.ProcSettings.ProcSoftwarePrefetcher (Read or Write) Table 922. Details of BIOS.ProcSettings.
NOTE: To enable BIOS.ProcSettings.ProcX2Apic, you must enable BIOS.ProcSettings.ProcVirtualization. Legal Values • • Default Value Disabled Write Privilege Server Control Enabled Disabled License Required iDRAC Express or iDRAC Enterprise Dependency Read Only if the ProcVirtualization attribute is set to Disabled. BIOS.ProcSettings.QpiBandwidthPriority (Read or Write) Table 925. Details of BIOS.ProcSettings.
Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.ProxyAttributes The objects in this group manage the legacy boot protocol of LOM. BIOS.ProxyAttributes.EmbNicPortnBootproto (Read or Write) Table 928. Details of BIOS.ProxyAttributes.EmbNicPortnBootproto attribute Description Controls the Legacy Boot Protocol of the LOM port specified by the Embedded NIC port. Assists in system management software and does not appear in system BIOS setup.
BIOS.PxeDev1Settings The objects in this group manage the PXE device settings. BIOS.PxeDev1Settings.PxeDevnInterface (Read or Write) Table 930. Details of BIOS.PxeDev1Settings.PxeDevnInterface attribute Description Indicates the NIC Interface used for the specified PXE device. For the attribute PxeDevnInterface, the value of n can be 1 — 4. Legal Values None Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.
Legal Values None Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.PxeDev1Settings.PxeDevnVlanPriority (Read or Write) Table 934. Details of BIOS.PxeDev1Settings.PxeDevnVlanPriority attribute Description Indicates the VLAN priority for the specific PXE device. For the attribute PxeDevnVlanPriority, the value of n can be 1 — 4.
License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.SataSettings.eSataPort1Capacity (Read or Write) Table 936. Details of BIOS.SataSettings.eSataPort1Capacity attribute Description Displays the total capacity of a hard-disk drive. Legal Values None Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.SataSettings.eSataPort1DriveType (Read or Write) Table 937. Details of BIOS.SataSettings.
Legal Values • • Default Value Not Applicable Write Privilege Server Control Off Auto License Required iDRAC Express or iDRAC Enterprise Dependency Read Only if EmbSata is not set to AtaMode. BIOS.SataSettings.SataPortACapacity (Read or Write) Table 940. Details of IOS.SataSettings.SataPortACapacity attribute Description Displays the total capacity of a hard-disk drive.
BIOS.SataSettings.SataPortB (Read or Write) Table 943. Details of BIOS.SataSettings.SataPortB attribute Description Sets the drive type of the selected device. Legal Values • • Default Value Not Applicable Write Privilege Server Control Off Auto License Required iDRAC Express or iDRAC Enterprise Dependency Read Only if EmbSata is not set to AtaMode. BIOS.SataSettings.SataPortBCapacity (Read or Write) Table 944. Details of BIOS.SataSettings.
Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.SataSettings.SataPortC (Read or Write) Table 947. Details of BIOS.SataSettings.SataPortC attribute Description Sets the drive type of the selected device. Legal Values • • Default Value Not Applicable Write Privilege Server Control Off Auto License Required iDRAC Express or iDRAC Enterprise Dependency Read Only if EmbSata is not set to AtaMode. BIOS.SataSettings.
BIOS.SataSettings.SataPortCModel (Read or Write) Table 950. Details of BIOS.SataSettings.SataPortCModel attribute Description Displays the drive model of the selected device. Legal Values None Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.SataSettings.SataPortD (Read or Write) Table 951. Details of BIOS.SataSettings.SataPortD attribute Description Sets the drive type of the selected device.
Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.SataSettings.SataPortDModel (Read or Write) Table 954. Details of BIOS.SataSettings.SataPortDModel attribute Description Displays the drive model of the selected device. Legal Values None Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.SataSettings.SataPortE (Read or Write) Table 955. Details of BIOS.
BIOS.SataSettings.SataPortEDriveType (Read or Write) Table 957. Details of BIOS.SataSettings.SataPortEDriveType attribute Description Indicates type of device attached to this SATA port. Legal Values None Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.SataSettings.SataPortEModel (Read or Write) Table 958. Details of BIOS.SataSettings.
Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.SataSettings.SataPortFDriveType (Read or Write) Table 961. Details of BIOS.SataSettings.SataPortFDriveType attribute Description Indicates type of device attached to this SATA port. Legal Values None Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.SataSettings.SataPortFModel (Read or Write) Table 962.
BIOS.SataSettings.SataPortGCapacity (Read or Write) Table 964. Details of BIOS.SataSettings.SataPortGCapacity attribute Description Displays the total capacity of a hard-disk drive. Legal Values None Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.SataSettings.SataPortGDriveType (Read or Write) Table 965. Details of BIOS.SataSettings.
Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Read Only if EmbSata is not set to AtaMode. BIOS.SataSettings.SataPortHCapacity (Read or Write) Table 968. Details of BIOS.SataSettings.SataPortHCapacity attribute Description Displays the total capacity of a hard disk drive. Legal Values None Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.SataSettings.
BIOS.SataSettings.SataPortI (Read or Write) Table 971. Details of BIOS.SataSettings.SataPortI attribute Description Sets the drive type of the selected device. When the Embedded SATA setting is in: • • ATA Mode, setting this attribute to Auto will enable the BIOS support for the device. Select Off to turn off the BIOS support for the device. AHCI Mode or RAID Mode, the BIOS always enables support for the device.
License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.SataSettings.SataPortJ (Read or Write) Table 975. Details of BIOS.SataSettings.SataPortJ attribute Description Sets the drive type of the selected device. When the Embedded SATA setting is in: • • ATA Mode, set this property to Auto to enable the BIOS support for the device. Select Off to turn off the BIOS support for the device. AHCI Mode or RAID Mode, the BIOS always enables support for the device.
BIOS.SataSettings.SataPortJModel (Read or Write) Table 978. Details of BIOS.SataSettings.SataPortJModel attribute Description Displays the drive model of the selected device. Legal Values Not Applicable Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.SataSettings.SecurityFreezeLock (Read or Write) Table 979. Details of BIOS.SataSettings.
Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.SerialCommSettings.ExtSerialConnector (Read or Write) Table 981. Details of BIOS.SerialCommSettings.ExtSerialConnector attribute Description Associate the External Serial Connector to Serial 1 or Serial 2 or Remote Access Device.
Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.SerialCommSettings.SerialComm (Read or Write) Table 984. Details of BIOS.SerialCommSettings.SerialComm attribute Description Controls the serial communication options. Legal Values • • • • • Default Value Not Applicable Write Privilege Server Control Off OnNoConRedir OnConRedirCom1 OnConRedirCom2 OnConRedir License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.
Legal Values • • • Default Value Not Applicable Write Privilege Server Control Enabled Disabled BootDriverDisabled License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.SlotDisablement.Slot2 (Read or Write) Table 987. Details of BIOS.SlotDisablement.Slot2 attribute Description Control the configuration of the card installed in slot 2.
Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.SlotDisablement.Slot5 (Read or Write) Table 990. Details of IOS.SlotDisablement.Slot5 attribute Description Control the configuration of the card installed in slot 5. Legal Values • • • Default Value Not Applicable Write Privilege Server Control Enabled Disabled BootDriverDisabled License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.SlotDisablement.
Dependency None BIOS.SlotDisablement.Slot8 (Read or Write) Table 993. Details of BIOS.SlotDisablement.Slot8 attribute Description Controls configuration of the card installed in this slot. You can set one of the following options for each card: • • • Enabled: The card is available during POST or to the operating system. Disabled: The card is not available during POST or to the operating system.
BIOS.SlotDisablement.Slot10 (Read or Write) Table 995. Details of BIOS.SlotDisablement.Slot10 attribute Description Controls configuration of the card installed in this slot. You can set one of the following option for each card. • • • Enabled: The card is available during POST or to the operating system. Disabled: The card is not available during POST or to the operating system.
BIOS.SysInformation.SystemBiosVersion (Read or Write) Table 997. Details of BIOS.SysInformation.SystemBiosVersion attribute Description Provides the current revision of the system BIOS firmware. Legal Values None Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.SysInformation.SystemCpldVersion (Read or Write) Table 998. Details of IOS.SysInformation.
Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.SysInformation.SystemServiceTag (Read or Write) Table 1001. Details of BIOS.SysInformation.SystemServiceTag attribute Description The Service Tag assigns the Original Equipment Manufacturer of this system. Legal Values None Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency` None BIOS.SysInformation.
License Required iDRAC Express or iDRAC Enterprise Dependency Enabled only when SysProfileSettings.ProcPwrPerf is set to SysDbpm in Custom mode. BIOS.SysProfileSettings.EnergyEfficientTurbo (Read or Write) Table 1004. Details of BIOS.SysProfileSettings.EnergyEfficientTurbo attribute Description Enables or disables the energy efficient turbo.
License Required iDRAC Express or iDRAC Enterprise Dependency Read Only if SysProfileSettings.SysProfile is not set to Custom mode. BIOS.SysProfileSettings.MemPatrolScrub (Read or Write) Table 1007. Details of BIOS.SysProfileSettings.MemPatrolScrub attribute Description Patrol scrubbing is a feature that searches the memory for errors and repairs correctable errors to prevent the accumulation of memory errors.
BIOS.SysProfileSettings.MemVolt (Read or Write) Table 1010. Details of BIOS.SysProfileSettings.MemVolt attribute Description Sets the DIMM voltage selection. Legal Values • • • Default Value Not Applicable Write Privilege Server Control AutoVolt Volt135V Volt15V License Required iDRAC Express or iDRAC Enterprise Dependency Read Only if SysProfileSettings.SysProfile is set to Custom mode. BIOS.SysProfileSettings.MonitorMwait (Read or Write) Table 1011. Details of BIOS.SysProfileSettings.
BIOS.SysProfileSettings.Proc1TurboCoreNum (Read or Write) Description Controls the number of Turbo Boost enabled cores for processor 1. By reducing the number of cores enabled with Turbo Boost, the maximum turbo frequency on the cores with Turbo Boost may be higher. Read-only unless System Profile is set to Custom. Legal Values • • • • • Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable All 1 2 4 6 BIOS.
BIOS.SysProfileSettings.ProcCStates (Read or Write) Table 1014. Details of BIOS.SysProfileSettings.ProcCStates attribute Description Enables or disables the processor C-States. Legal Values • • Default Value Not Applicable Write Privilege Server Control Enabled Disabled License Required iDRAC Express or iDRAC Enterprise Dependency Read Only if SysProfileSettings.SysProfile is not set to Custom mode. BIOS.SysProfileSettings.ProcPwrPerf (Read or Write) Table 1015. Details of BIOS.
Legal Values • • Default Value Not Applicable Write Privilege Server Control Enabled Disabled License Required iDRAC Express or iDRAC Enterprise Dependency Read Only if SysProfileSettings.SysProfile is not set to Custom mode. BIOS.SysProfileSettings.SysProfile (Read or Write) Table 1018. Details of BIOS.SysProfileSettings.SysProfile attribute Description Sets the System Profile to Performance Per Watt (DAPC), Performance Per Watt (OS) Performance Dense Configuration, or Custom mode.
BIOS.SysProfileSettings.UncoreFrequency (Read or Write) Table 1020. Details of IOS.SysProfileSettings.UncoreFrequency attribute Description Selects the processor uncore frequency. Legal Values • • • Default Value Not Applicable Write Privilege Server Control DynamicUFS MaxUFS MinUFS License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.SysProfileSettings.WorkloadProfile (Read or Write) Description Allows optimization of performance based on the workload type.
BIOS.SysSecurity.AcPwrRcvry (Read or Write) Table 1022. Details of BIOS.SysSecurity.AcPwrRcvry attribute Description Specifies how the system responds after AC power is restored to the system. It is useful when the system is turned off with a power strip. Legal Values • • • Default Value Not Applicable Write Privilege Server Control On Off Last License Required iDRAC Express or iDRAC Enterprise Dependency Read Only if SysSecurity.AcPwrRcvry is set to Off. BIOS.SysSecurity.
Legal Values • • Default Value Not Applicable Write Privilege Server Control Enabled Disabled License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.SysSecurity.BiosUpdateControl (Read or Write) Table 1026. Details of BIOS.SysSecurity.BiosUpdateControl attribute Description If this attribute is set to Unlocked, then all BIOS update is allowed.
BIOS.SysSecurity.NmiButton (Read or Write) Table 1028. Details of BIOS.SysSecurity.NmiButton attribute Description Enables or disables the NMI button on the front panel. Legal Values • • Default Value Not Applicable Write Privilege Server Control Enabled Disabled License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.SysSecurity.PasswordStatus (Read or Write) Table 1029. Details of BIOS.SysSecurity.PasswordStatus attribute Description Locks the system password.
Legal Values • • Default Value Not Applicable Write Privilege Server Control Enabled Disabled License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.SysSecurity.SecureBootPolicy (Read or Write) Description Allows selecting the Secure Boot Policy. When set to Standard, the BIOS uses the key and certificates from the system manufacturer to authenticate pre-boot images. When set to Custom, the BIOS uses the user-customized key and certificates.
Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.SysSecurity.SHA256SetupPasswordSalt (Read or Write) Table 1034. Details of BIOS.SysSecurity.SHA256SetupPasswordSalt attribute Description Indicates the Salt string added to the setup password before hash.
Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.SysSecurity.SHA256SystemPassword (Read or Write) Table 1037. Details of BIOS.SysSecurity.SHA256SystemPassword attribute Description Indicates the SHA256 hash of the system password. Legal Values String of 64 characters Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.SysSecurity.
BIOS.SysSecurity.TcmClear (Read or Write) Table 1040. Details of BIOS.SysSecurity.TcmClear attribute Description Warns that clearing the TPM causes loss of all keys in the TPM. It may affect starting the operating system. Legal Values • • Default Value Not Applicable Write Privilege Server Control Yes No License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.SysSecurity.TcmSecurity (Read or Write) Table 1041. Details of BIOS.SysSecurity.
Legal Values • • Default Value Not Applicable Write Privilege Server Control Yes No License Required iDRAC Express or iDRAC Enterprise Dependency Read Only if SysSecurity.TpmSecurity is set to Off. BIOS.SysSecurity.TpmFirmware Table 1044. Details of BIOS.SysSecurity.TpmFirmware attribute Description Displays the firmware version of the Trusted Platform Module (TPM). Legal Values NA Default Value NA Write Privilege Server control License Required RACADM Dependency None BIOS.SysSecurity.
BIOS.SysSecurity.TpmPpiBypassProvision Table 1046. Details of BIOS.SysSecurity.TpmPpiBypassProvision attribute Description Enables or disables the Physical Presence Interface (PPI) Advanced Configuration and Power Interface (ACPI) and this feature enables operating system to by-pass the PPI-related prompts. Legal Values • • Default Value NA Write Privilege Server control Enabled Disabled License Required RACADM Dependency None BIOS.SysSecurity.TpmSecurity (Read or Write) Table 1047.
Legal Values • • Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable Standard Controlled BIOS.UefiBootSettings The objects in this group manages the UEFI boot settings. BIOS.UefiBootSettings.UefiBootSeq (Read or Write) Table 1049. Details of BIOS.UefiBootSettings.UefiBootSeq attribute Description Controls the UEFI boot order. The first option in the list is tried first.
Default Value Not Applicable Write Privilege Not Applicable License Required iDRAC Express or iDRAC Enterprise Dependency Not Applicable FC.FCDevice.ChipMdl (Read Only) Table 1052. Details of FC.FCDevice.ChipMdl attribute Description Indicates the PCI configuration space information. Legal Values Not Applicable Default Value Not Applicable Write Privilege Not Applicable License Required iDRAC Express or iDRAC Enterprise Dependency Not Applicable FC.FCDevice.EFIVersion (Read Only) Table 1053.
Write Privilege Not Applicable License Required iDRAC Express or iDRAC Enterprise Dependency Not Applicable FC.FCTarget The objects in this group manage the Fibre Channel target. FC.FCTarget.BootScanSelection (Read or Write) Table 1056. Details of FC.FCTarget.BootScanSelection attribute Description Sets the port’s operation while starting the system from Fiber Channel target(s). Only operations supported by the option-ROM should be implemented.
FC.FCTarget.FirstFCTargetWWPN (Read or Write) Table 1059. Details of FC.FCTarget.FirstFCTargetWWPN attribute Description Specifies the World Wide Port Name of the first Fibre Channel boot target. Legal Values Not Applicable Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not Applicable FC.FCTarget.SecondFCTargetWWPN (Read or Write) Table 1060. Details of FC.FCTarget.
License Required iDRAC Express or iDRAC Enterprise Dependency Not Applicable FC.HBAConfig.FabricLoginRetryCount (Read or Write) Table 1063. Details of FC.HBAConfig.FabricLoginRetryCount attribute Description Sets the current SAN Fabric login retry count. Legal Values Not Applicable Default Value 3 Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not Applicable FC.HBAConfig.FramePayloadSize (Read or Write) Table 1064. Details of FC.HBAConfig.
Legal Values Not Applicable Default Value 0 Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not Applicable FC.HBAConfig.LinkDownTimeout (Read or Write) Table 1067. Details of FC.HBAConfig.LinkDownTimeout attribute Description Sets the Link down time out. Legal Values Not Applicable Default Value 3000 Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not Applicable FC.HBAConfig.
Default Value 3000 Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not Applicable FC.HBAConfig.PortLoginRetryCount (Read or Write) Table 1071. Details of FC.HBAConfig.PortLoginRetryCount attribute Description Sets the target Port login retry count. Legal Values Not Applicable Default Value 3 Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not Applicable FC.HBAConfig.
FC.PortConfig.FCDevice (Read Only) Table 1074. Details of FC.PortConfig.FCDevice attribute Description Displays the version of the device and firmware. Legal Values Not Applicable Default Value Not Applicable Write Privilege Not Applicable License Required iDRAC Express or iDRAC Enterprise Dependency Not Applicable FC.PortConfig.FCTarget (Read Only) Table 1075. Details of FC.PortConfig.
FC.PortConfig.PortSpeed (Read or Write) Table 1078. Details of FC.PortConfig.PortSpeed attribute Description Specifies the data rate of the Fibre Channel Host Bus Adapter port. The value can be Automatic or specified in Gbps. Legal Values • • • • • • Default Value Auto Write Privilege Sever Control Auto 1G 2G 4G 8G 16G License Required iDRAC Express or iDRAC Enterprise Dependency Not Applicable FC.PortConfig.VirtualWWN (Read or Write) Table 1079. Details of FC.PortConfig.
Write Privilege Not Applicable License Required iDRAC Express or iDRAC Enterprise Dependency Not Applicable FC.PortConfig.WWPN (Read Only) Table 1082. Details of FC.PortConfig.WWPN attribute Description Indicates the permanent Fibre Channel World Wide Port Name assigned to the port. Legal Values Not Applicable Default Value Not Applicable Write Privilege Not Applicable License Required iDRAC Express or iDRAC Enterprise Dependency Not Applicable NIC.
Legal Values Not Applicable Default Value Not Applicable Write Privilege Not Applicable License Required iDRAC Express or iDRAC Enterprise Dependency Not Applicable NIC.ConfigureFormn.IscsiMacAddr (Read Only) Table 1086. Details of NIC.ConfigureFormn.IscsiMacAddr attribute Description Indicates the permanent MAC address for iSCSI off load.
NIC.ConfigureFormn.NicMode (Read or Write) Table 1089. Details of NIC.ConfigureFormn.NicMode attribute Description Enables or disables the NIC mode on the partition. Legal Values • • Default Value Disabled Write Privilege Server Control Enabled Disabled License Required iDRAC Express or iDRAC Enterprise Dependency Not Applicable NIC.ConfigureFormn.PCIDeviceID (Read Only) Table 1090. Details of NIC.ConfigureFormn.PCIDeviceID attribute Description Indicates the PCI Device ID of the partition.
NIC_ConfigureFormn.VirtWWN (Read or Write) Table 1093. Details of attribute Description Sets the Fibre Channel World Wide Node Name identifier for partition FCoE. Legal Values Not Applicable Default Value 00:00:00:00:00:00:00:00 Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not Applicable NIC_ConfigureFormn.VirtWWPN (Read or Write) Table 1094. Details of NIC_ConfigureFormn.
NIC_ConfigureFormn.VirtFIPMacAddr (Read or Write) Table 1097. Details of NIC_ConfigureFormn.VirtFIPMacAddr attribute Description Assigns the FIP-MAC address for partition FCoE. Legal Values Not Applicable Default Value 00:00:00:00:00:00 Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not Applicable NIC.DCBSettings The following section provides information about the objects in the NIC.DCBSettings group. NIC.DCBSettings.
NIC.DCBSettings.EnhancedTransmissionSelection (Read Only) Table 1100. Details of NIC.DCBSettings.EnhancedTransmissionSelection attribute Description Indicates whether Enhanced Transmission Selection capability is supported. Legal Values • • Default Value Not Applicable Write Privilege Not Applicable Available Unavailable License Required iDRAC Express or iDRAC Enterprise Dependency None NIC.DCBSettings.PriorityFlowControl (Read Only) Table 1101. Details of NIC.DCBSettings.
Dependency None NIC.DeviceLevelConfig.FlowControlSetting (Read or Write) Table 1103. Details of NIC.DeviceLevelConfig.FlowControlSetting attribute Description Configure type of Flow Control used. Legal Values • • • • Default Value Auto Write Privilege Server Control Auto TX:Send Pause on RX Overflow RX:Throttle TX on Pause Received TX RX Flow Control License Required iDRAC Express or iDRAC Enterprise Dependency None NIC.DeviceLevelConfig.NParEP (Read or Write) Table 1104.
NIC.DeviceLevelConfig.SRIOVSupport (Read Only) Table 1105. Details of NIC.DeviceLevelConfig.SRIOVSupport attribute Description Indicates whether SR-IOV capability is supported. Legal Values • • Default Value Not Applicable Write Privilege Not Applicable Available Unavailable License Required iDRAC Express or iDRAC Enterprise Dependency` None NIC.DeviceLevelConfig.VFAllocBasis (Read Only) Description Defines the domain in which Virtual Functions are allocated; either Port or Device.
License Required iDRAC Express or iDRAC Enterprise Dependency Not Applicable NOTE: For Emulex cards, the VirtualizationMode attribute is found under the VndrConfigPage group instead of the DeviceLevelConfig group. NIC.FCOECapabilities The following section provides information about the objects in the NIC.FCOECapabilities group. NIC.FCOECapabilities.AddressingMode (Read Only) Table 1107. Details of NIC.FCOECapabilities.
NIC.FCOECapabilities.MaxNPIVPerPort (Read Only) Table 1110. Details of NIC.FCOECapabilities.MaxNPIVPerPort attribute Description Indicates the maximum number of NPIV WWN per port. Legal Values None Default Value Not Applicable Write Privilege Not Applicable License Required iDRAC Express or iDRAC Enterprise Dependency None NIC.FCOECapabilities.MaxNumberExchanges (Read Only) Table 1111. Details of NIC.FCOECapabilities.
Write Privilege Not Applicable License Required iDRAC Express or iDRAC Enterprise Dependency None NIC.FCOECapabilities.MaxNumberOutStandingCommands (Read Only) Table 1114. Details of NIC.FCOECapabilities.MaxNumberOutStandingCommands attribute Description Indicates the maximum number of outstanding commands supported across all sessions. Legal Values None Default Value Not Applicable Write Privilege Not Applicable License Required iDRAC Express or iDRAC Enterprise Dependency None NIC.
Default Value Disabled Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency None NIC.FCoEConfiguration.BootOrderFirstFCoETarget (Read or Write) Table 1117. Details of NIC.FCoEConfiguration.BootOrderFirstFCoETarget attribute Description Specifies the port’s target in the FCoE boot order. Legal Values Not Applicable Default Value 0 Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not Applicable NIC.
NIC.FCoEConfiguration.BootOrderFourthFCoETarget (Read or Write) Table 1120. Details of NIC.FCoEConfiguration.BootOrderFourthFCoETarget attribute Description Specifies the port's fourth defined target in the FCoE boot. Legal Values Not Applicable Default Value 0 Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not Applicable NIC.FCoEConfiguration.FirstFCoEBootTargetLUN (Read or Write) Table 1121. Details of NIC.FCoEConfiguration.
NIC.FCoEConfiguration.FirstFCoEWWPNTarget (Read or Write) Table 1123. Details of NIC.FCoEConfiguration.FirstFCoEWWPNTarget attribute Description World Wide Port Name (WWPN) of the first FCoE storage target. Legal Values None Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency None NIC.FCoEConfiguration.MTUParams (Read or Write) Table 1124. Details of NIC.FCoEConfiguration.
Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency None NIC.FCoEGenParams.FCoEFabricDiscoveryRetryCnt (Read or Write) Table 1126. Details of NIC.FCoEGenParams.FCoEFabricDiscoveryRetryCnt attribute Description Retry count for FCoE fabric discovery. Legal Values Values: 0–60 Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency None NIC.FCoEGenParams.
License Required iDRAC Express or iDRAC Enterprise Dependency None NIC.FCoEGenParams.FCoELunBusyRetryCnt (Read or Write) Table 1129. Details of NIC.FCoEGenParams.FCoELunBusyRetryCnt attribute Description Specifies the number of connection retries the FCoE boot initiator will attempt if the FCoE target LUN is busy. Legal Values Values: 0–60 Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency None NIC.FCoEGenParams.
NIC.FrmwImgMenu.EFIVersion (Read Only) Table 1132. Details of NIC.FrmwImgMenu.EFIVersion attribute Description Indicates the EFI device driver version information. Legal Values String of up to 8 ASCII characters Default Value Not Applicable Write Privilege Not Applicable License Required iDRAC Express or iDRAC Enterprise Dependency None NIC.FrmwImgMenu.FamilyVersion (Read Only) Table 1133. Details of IC.FrmwImgMenu.
NIC.GlobalBandwidthAllocation.MinBandwidth (Read or Write) Table 1135. Details of NIC.GlobalBandwidthAllocation.MinBandwidth attribute Description Set the minimum percentage of port TX bandwidth allocated to partition. Legal Values Values: 0–100 Default Value 25 Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency None NIC.IscsiFirstTgtParams The following section provides information about the objects in the NIC.IscsiFirstTgtParams group. NIC.
NIC.IscsiFirstTgtParams.FirstTgtBootLun (Read or Write) Table 1138. Details of NIC.IscsiFirstTgtParams.FirstTgtBootLun attribute Description Set the first iSCSI storage target boot Logical Unit Number (LUN). Legal Values Values: 0–18446744073709551615 Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not Available if VndrConfigGroup.iSCSIBootSupport is Unavailable. NIC.IscsiFirstTgtParams.
Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not Available if VndrConfigGroup.iSCSIBootSupport is Unavailable. NIC.IscsiFirstTgtParams.FirstTgtIpVer (Read or Write) Table 1142. Details of NIC.IscsiFirstTgtParams.FirstTgtIpVer attribute Description Specifies whether or not IPv4 or IPv6 network address is used for first iSCSI target.
NIC.IscsiGenParams The following section provides information about the objects in the NIC.IscsiGenParams group. NIC.IscsiGenParams.ChapAuthEnable (Read or Write) Table 1145. Details of NIC.IscsiGenParams.ChapAuthEnable attribute Description To use CHAP authentication when connecting to the iSCSI target, enable or disable the ability of the initiator.
NIC.IscsiGenParams.FirstHddTarget (Read or Write) Table 1148. Details of NIC.IscsiGenParams.FirstHddTarget attribute Description Enables or disables to check if the iSCSI target appears as the first hard disk drive (HDD) in the system. Legal Values • • Default Value Disabled Write Privilege Server Control Enabled Disabled License Required iDRAC Express or iDRAC Enterprise Dependency Not Available if VndrConfigGroup.iSCSIBootSupport is Unavailable. NIC.IscsiGenParams.
NIC.IscsiGenParams.IscsiTgtBoot (Read or Write) Table 1151. Details of NIC.IscsiGenParams.IscsiTgtBoot attribute Description Specifies whether or not the iSCSI initiator will boot to the specified iSCSI target after connection. Legal Values • • • Default Value Disabled Write Privilege Server Control Enabled Disabled OneTimeDisabled License Required iDRAC Express or iDRAC Enterprise Dependency Not Applicable NIC.IscsiGenParams.IscsiViaDHCP (Read or Write) Table 1152. Details of NIC.IscsiGenParams.
Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not Applicable NIC.IscsiGenParams.LnkUpDelayTime (Read or Write) Table 1155. Details of NIC.IscsiGenParams.LnkUpDelayTime attribute Description Set the time to allow for link to establish before driver initialization. Legal Values Values from 0 to 255 Default Value 0 Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not Available if VndrConfigGroup.
NIC.IscsiGenParams.TcpTimestmp (Read or Write) Table 1158. Details of NIC.IscsiGenParams.TcpTimestmp attribute Description Enables or disables use of TCP timestamps in network packets as defined in RFC 1323. Legal Values • • Default Value Disabled Write Privilege Server Control Enabled Disabled License Required iDRAC Express or iDRAC Enterprise Dependency Not Available if VndrConfigGroup.iSCSIBootSupport is Unavailable. NIC.IscsiGenParams.WinHbaBootMode (Read or Write) Table 1159. Details of NIC.
NIC.IscsiInitiatorParams.IscsiInitiatorChapPwd (Read or Write) Table 1161. Details of NIC.IscsiInitiatorParams.IscsiInitiatorChapPwd attribute Description Set the iSCSI initiator Challenge-Handshake Authentication Protocol (CHAP) secret (password). Legal Values String of 12–16 characters Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not available if VndrConfigGroup.iSCSIBootSupport is unavailable. NIC.IscsiInitiatorParams.
NIC.IscsiInitiatorParams.IscsiInitiatorName (Read or Write) Table 1164. Details of NIC.IscsiInitiatorParams.IscsiInitiatorName attribute Description Specifies the initiator iSCSI Qualified Name (IQN). Legal Values String of upto 223 characters Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not available if VndrConfigGroup.iSCSIBootSupport is unavailable. NIC.IscsiInitiatorParams.
NIC.IscsiInitiatorParams.IscsiInitiatorSubnet (Read or Write) Table 1167. Details of NIC.IscsiInitiatorParams.IscsiInitiatorSubnet attribute Description Specifies the IPv4 Subnet Mask of the iSCSI initiator. Legal Values String of 7–15 characters (IPv4 Subnet) Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not available if VndrConfigGroup.iSCSIBootSupport is unavailable. NIC.IscsiInitiatorParams.
NIC.IscsiSecondaryDeviceParams.UseIndTgtName (Read or Write) Table 1170. Details of NIC.IscsiSecondaryDeviceParams.UseIndTgtName attribute Description Specifies whether to use Independent Target Name when multipath I/O is enabled. Legal Values • • Default Value Disabled Write Privilege Server Control Enabled Disabled License Required iDRAC Express or iDRAC Enterprise Dependency Not available if VndrConfigGroup.iSCSIBootSupport is unavailable. NIC.IscsiSecondaryDeviceParams.
License Required iDRAC Express or iDRAC Enterprise Dependency Not available if VndrConfigGroup.iSCSIBootSupport is unavailable. NIC.IscsiSecondTgtParams.SecondTgtBootLun (Read or Write) Table 1173. Details of NIC.IscsiSecondTgtParams.SecondTgtBootLun attribute Description Specifies the second iSCSI storage target boot Logical Unit Number (LUN).
NIC.IscsiSecondTgtParams.SecondTgtIpAddress (Read or Write) Table 1176. Details of NIC.IscsiSecondTgtParams.SecondTgtIpAddress attribute Description Specifies the IP address of the second iSCSI target. Legal Values String of 2-39 characters (Ipv4 or Ipv6 address) Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not available if VndrConfigGroup.iSCSIBootSupport is unavailable. NIC.IscsiSecondTgtParams.
NIC.IscsiSecondTgtParams.SecondTgtTcpPort (Read or Write) Table 1179. Details of NIC.IscsiSecondTgtParams.SecondTgtTcpPort attribute Description Specifies the TCP Port number of the second iSCSI target. Legal Values Values: 1–65535 Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not available if VndrConfigGroup.iSCSIBootSupport is unavailable. NIC.
Legal Values • • • • • • • • Default Value NoRetry Write Privilege Server Control NoRetry 1Retry 2Retries 3Retries 4Retries 5Retries 6Retries IndefiniteRetries License Required iDRAC Express or iDRAC Enterprise Dependency Not Applicable NIC.NICConfig.BootStrapType (Read or Write) Table 1183. Details of NIC.NICConfig.BootStrapType attribute Description Specifies the boot strap method used to start the operating system.
• • • • FCoE NONE iSCSIPrimary iSCSI Secondary Default Value None Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency None NIC.NICConfig.LnkSpeed (Read or Write) Table 1186. Details of NIC.NICConfig.LnkSpeed attribute Description Specifies the port speed used for the selected boot protocol.
License Required iDRAC Express or iDRAC Enterprise Dependency VLanMode must be enabled. NIC.NICConfig.VLanMode (Read or Write) Table 1189. Details of NIC.NICConfig.VLanMode attribute Description Virtual LAN mode enables use of a VLAN tag to use vendor-defined boot protocols. Legal Values • • Default Value Disabled Write Privilege Server Control Enabled Disabled License Required iDRAC Express or iDRAC Enterprise Dependency None NIC.NICConfig.WakeOnLan (Read or Write) Table 1190. Details of NIC.
NIC.NICPartitioningConfig To configure the NICPartitioning properties, use the objects in this group. NIC.NICPartitioningConfig.NicPartitioning (Read or Write) Table 1192. Details of NIC.NICPartitioningConfig.NicPartitioning attribute Description Enables or disables NIC partitioning for all device ports. Legal Values • • Default Value Disabled Write Privilege Server Control Enabled Disabled License Required iDRAC Express or iDRAC Enterprise Dependency None NIC.NICPartitioningConfig.
NIC.NICPartitioningConfig.NumberPCIEFunctionsEnabled (Read Only) Table 1195. Details of NIC.NICPartitioningConfig.NumberPCIEFunctionsEnabled attribute Description Indicates the number of physical PCIe functions currently enabled on this port. Legal Values Values: 1–65535 Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency None NIC.NICPartitioningConfig.NumberPCIEFunctionsSupport ed (Read Only) Table 1196. Details of NIC.
NIC.VndrConfigGroup.BlnkLeds (Read or Write) Table 1198. Details of NIC.VndrConfigGroup.BlnkLeds attribute Description Identifies the physical network port by blinking the associated LED. Legal Values Values: 0–15 Default Value 15 Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency None NIC.VndrConfigGroup.ChipMdl (Read Only) Table 1199. Details of NIC.VndrConfigGroup.ChipMdl attribute Description Indicates the chip type or revision.
Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency None NIC.VndrConfigGroup.DeviceName (Read Only) Table 1202. Details of NIC.VndrConfigGroup.DeviceName attribute Description Official product name of the device. Legal Values Not Applicable Default Value Not Applicable Write Privilege Not Applicable License Required iDRAC Express or iDRAC Enterprise Dependency Not Applicable NIC.VndrConfigGroup.FCoEBootSupport (Read Only) Table 1203. Details of NIC.
NIC.VndrConfigGroup.FCoEOffloadSupport (Read Only) Table 1205. Details of NIC.VndrConfigGroup.FCoEOffloadSupport attribute Description Indicates whether FCoE Offload capability is supported. Legal Values None Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency None NIC.VndrConfigGroup.FeatureLicensingSupport (Read Only) Table 1206. Details of NIC.VndrConfigGroup.
Write Privilege Not Applicable License Required iDRAC Express or iDRAC Enterprise Dependency None NIC.VndrConfigGroup.iSCSIBootSupport (Read Only) Table 1209. Details of NIC.VndrConfigGroup.iSCSIBootSupport attribute Description Indicates whether iSCSI Boot capability is supported. Legal Values None Default Value Not Applicable Write Privilege Not Applicable License Required iDRAC Express or iDRAC Enterprise Dependency None NIC.VndrConfigGroup.ISCSIMacAddr (Read Only) Table 1210.
NIC.VndrConfigGroup.iSCSIOffloadSupport (Read Only) Table 1212. Details of NIC.VndrConfigGroup.iSCSIOffloadSupport attribute Description Indicates whether iSCSI Offload capability is supported. Legal Values None Default Value Not Applicable Write Privilege Not Applicable License Required iDRAC Express or iDRAC Enterprise Dependency None NIC.VndrConfigGroup.LinkStatus (Read Only) Table 1213. Details of NIC.VndrConfigGroup.
License Required iDRAC Express or iDRAC Enterprise Dependency None NIC.VndrConfigGroup.NicPartitioningSupport (Read Only) Table 1216. Details of NIC.VndrConfigGroup.NicPartitioningSupport attribute Description Indicates whether NIC Partitioning capability is supported. Legal Values None Default Value Not Applicable Write Privilege Not Applicable License Required iDRAC Express or iDRAC Enterprise Dependency None NIC.VndrConfigGroup.NWManagementPassThrough (Read Only) Table 1217. Details of NIC.
NIC.VndrConfigGroup.OSBMCManagementPassThrough (Read Only) Table 1219. Details of NIC.VndrConfigGroup.OSBMCManagementPassThrough attribute Description Indicates whether OS-BMC Management Pass Through capability is supported. Legal Values None Default Value Not Applicable Write Privilege Not Applicable License Required iDRAC Express or iDRAC Enterprise Dependency None NIC.VndrConfigGroup.PCIDeviceID (Read Only) Table 1220. Details of NIC.VndrConfigGroup.
License Required iDRAC Express or iDRAC Enterprise Dependency None NIC.VndrConfigGroup.RXFlowControl (Read Only) Table 1223. Details of NIC.VndrConfigGroup.RXFlowControl attribute Description Indicates whether Receive (RX) Flow control capability is supported. Legal Values None Default Value Not Applicable Write Privilege Not Applicable License Required iDRAC Express or iDRAC Enterprise Dependency None NIC.VndrConfigGroup.TOESupport (Read Only) Table 1224. Details of NIC.VndrConfigGroup.
NIC.VndrConfigGroup.TXBandwidthControlMinimum (Read Only) Table 1226. Details of NIC.VndrConfigGroup.TXBandwidthControlMinimum attribute Description Indicates whether Transmit (TX) Bandwidth Control Minimum capability is supported. Legal Values None Default Value Not Applicable Write Privilege Not Applicable License Required iDRAC Express or iDRAC Enterprise Dependency None NIC.VndrConfigGroup.TXFlowControl (Read Only) Table 1227. Details of NIC.VndrConfigGroup.
Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency None NIC.VndrConfigGroup.VirtMacAddr (Read or Write) Table 1230. Details of NIC.VndrConfigGroup.VirtMacAddr attribute Description Programmatically assignable MAC address. Programmatic write for support of I/O Identity feature. Legal Values String of up to 17 characters Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency None NIC.
NIC.VndrConfigGroup.VirtWWPN (Read or Write) Table 1233. Details of NIC.VndrConfigGroup.VirtWWPN attribute Description Programmatically assignable Fibre Channel World Wide Port Name identifier for FCoE. Legal Values String of up to 23 characters Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency None NIC.VndrConfigGroup.WWN (Read Only) Table 1234. Details of NIC.VndrConfigGroup.
Write Privilege None License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable NIC.VndrConfigPage.BusDeviceFunction (Read Only) Description The value of this attribute depends on the state of the NParEP Mode setting. If NParEP Mode is Disabled, the value is the BIOS assigned PCIe Bus:Device:Function identifier. If NParEP Mode is Enabled, the value is the BIOS assigned PCIe Bus:Function identifier.
NIC.VndrConfigPage.FIPMacAddr (Read Only) Description Permanent FIP-MAC address for FCoE assigned during manufacturing. If supported, the current address value should be readable at all times, irrespective of feature enablement. Legal Values None Default Value None Write Privilege None License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable NIC.VndrConfigPage.FlexAddressing (Read Only) Description Indicates whether the Dell FlexAddressing feature is supported.
NIC.VndrConfigPage.iScsiOffloadMode (Read or Write) Description Enable/Disable the iSCSI offload personality on the port. This setting is for when operating in non-NPar mode only. Legal Values • • Default Value Disabled Write Privilege None License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable Enabled Disabled NIC.VndrConfigPage.iSCSIOffloadSupport (Read Only) Description Indicates whether the iSCSI Offload capability is supported.
NIC.VndrConfigPage.NicPartitioningSupport (Read Only) Description Indicates whether the NIC Partitioning capability is supported. Legal Values • • Default Value None Write Privilege None License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable Available Unavailable NIC.VndrConfigPage.PCIDeviceID (Read Only) Description PCI Device ID reported by the controller when operating in non-NPar mode only.
NIC.VndrConfigPage.VirtFIPMacAddr (Read or Write) Description Programmatically assignable FIP-MAC address for FCoE. Virtual addresses written will also generate corresponding VWWNN and VWWPN addresses as defined in Y741D. The supported method of reverting to the permanent FIP-MAC address is by writing 0's as the virtual address. If the virtual address has not been set or if it has been cleared by the defined method, its value shall be returned as 0's.
License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable NIC.VndrConfigPage.WWN (Read Only) Description Fibre Channel World Wide Node Name identifier for FCoE Legal Values String of upto 23 characters Default Value None Write Privilege None License Required iDRAC Express or iDRAC Enterprise Dependency Not applicable NIC.VndrConfigPage.
Legal Values • • • • Default value None Write Privilege Server Control Automatic Warn Disabled Not Supported License Required iDRAC Express or iDRAC Enterprise Dependency A battery must be present on the controller. Storage.Controller.CheckConsistencyMode (Read or Write) Table 1238. Details of Storage.Controller.CheckConsistencyMode attribute Description Check Consistency feature is used to verify the accuracy of the redundant (parity) information.
Dependency None Storage.Controller.CopybackMode (Read or Write) Table 1241. Details of Storage.Controller.CopybackMode attribute Description This attribute represents the mode of restoring the configuration of a virtual disk when a failed physical disk drive is replaced in an array. Legal Values • • • Default value On Write Privilege Server Control On ON with SMART Off License Required iDRAC Express or iDRAC Enterprise Dependency None Storage.Controller.
Legal Values • • • Default value Automatic Write Privilege Server Control Automatic Manual Disabled License Required iDRAC Express or iDRAC Enterprise Dependency None Storage.Controller.PatrolReadRate (Read or Write) Table 1245. Details of Storage.Controller.PatrolReadRate attribute Description The Patrol Read Rate is the percentage of the system's resources dedicated to perform Patrol Read.
Storage.Controller.PossibleloadBalancedMode (Read or Write) Table 1248. Details of Storage.Controller.PossibleloadBalancedMode attribute Description This attribute represents the ability to automatically use both controller ports connected to the same enclosure to route I/O requests. Legal Values • • Default value Automatic Write Privilege Server Control Automatic Disabled License Required iDRAC Express or iDRAC Enterprise Dependency None Storage.Controller.RebuildRate (Read or Write) Table 1249.
• • HBA Not Supported Default value Not Applicable Write Privilege Server Control License Required RACADM Dependency None Storage.Controller.SupportControllerBootMode (Read Only) Table 1252. Details of Storage.Controller.SupportControllerBootMode attribute Description This is read only attribute. This property indicates if this controller supports setting of controller boot mode.
License Required iDRAC Express or iDRAC Enterprise Dependency None Storage.Controller.T10PICapability (Read Only) Table 1255. Details of Storage.Controller.T10PICapability attribute Description This is a read-only attribute. This property indicates if this controller supports T10 PI. Legal Values • • Default Value Not Applicable Write Privilege Configure iDRAC Incapable Capable License Required iDRAC Express or iDRAC Enterprise Dependency None Storage.
• • • • SplitMode–16:8 SplitMode–20:4 Not Applicable None Default Value UnifiedMode Write Privilege Server Control License Required RACADM Dependency Backplane must support. Storage.enclosure.BackplaneType (Read Only) Table 1258. Details of Storage.enclosure.BackplaneType attribute Description Indicates whether or not the backplane is shared.
• 12GBPS Default value Not Applicable Write Privilege Not Applicable License Required iDRAC Express or iDRAC Enterprise Dependency None Storage.PhysicalDisk.RaidNominalMediumRotationRate (Read Only) Table 1261. Details of Storage.PhysicalDisk.RaidNominalMediumRotationRate attribute Description This is a read-only attribute and represents the nominal medium rotation speed of a physical disk drive.
Dependency None Storage.VirtualDisk.DiskCachePolicy (Read or Write) Table 1264. Details of Storage.VirtualDisk.DiskCachePolicy attribute Description Set the physical disk drive caching policy of all members of a Virtual Disk by enabling the Disk Cache Policy. When this feature is enabled, the physical disk drive writes data to the physical disk drive cache before writing it to the physical disk drive.
License Required iDRAC Express or iDRAC Enterprise Dependency None Storage.VirtualDisk.WritePolicy (Read or Write) Table 1267. Details of the Storage.VirtualDisk.WritePolicy attribute Description The write policies specify whether or not the controller sends a write-request completion signal as soon as the data is in the cache or after it has been written to disk. NOTE: Storage.VirtualDisk.WritePolicy attribute is read-only for few PERCs—for example, H330.
A Deprecated and New Subcommands Table 1268.
B Legacy and New Groups and Objects Table 1269. Details of legacy groups and objects Legacy Groups and Objects New Groups and Objects idRacInfo iDRAC.Info idRacType Type idRacProductInfo Product idRacDescriptionInfo Description idRacVersionInfo Version idRacBuildInfo Build idRacName Name cfgActiveDirectory iDRAC.
Legacy Groups and Objects New Groups and Objects cfgLanNetworking iDRAC.Nic cfgNicEnable Enable cfgNicMacAddress MACAddress cfgDNSRacName DNSRacName cfgNicSelection Selection cfgNicFailoverNetwork Failover cfgDNSDomainName DNSDomainName cfgDNSDomainNameFromDHCP DNSRacName cfgDNSRegisterRac DNSRegister cfgNicVLanEnable VLanEnable cfgNicVLanID VLanID cfgNicVLanPriority VLanPriority iDRAC.
Legacy Groups and Objects New Groups and Objects cfgIPv6Address5 Address5 cfgIPv6Address6 Address6 cfgIPv6Address7 Address7 cfgIPv6Address8 Address8 cfgIPv6Address9 Address9 cfgIPv6Address10 Address10 cfgIPv6Address11 Address11 cfgIPv6Address12 Address12 cfgIPv6Address13 Address13 cfgIPv6Address14 Address14 cfgIPv6Address15 Address15 cfgIPv6DNSServersFromDHCP6 DNSFromDHCP6 cfgIPv6DNSServer1 DNS1 cfgIPv6DNSServer2 DNS2 cfgServerPower System.
Legacy Groups and Objects New Groups and Objects cfgServerPowerLastHourMaxPower Max.LastHour cfgServerPowerLastHourMaxTime Max.LastHour.Timestamp cfgServerPowerLastDayMinPower Min.LastDay cfgServerPowerLastDayMinTime Min.LastDay.Timestamp cfgServerPowerLastDayMaxPower Max.LastDay cfgServerPowerLastDayMaxTime Max.LastDay.Timestamp cfgServerPowerLastWeekMinPower Min.LastWeek cfgServerPowerLastWeekMinTime Min.LastWeek.Timestamp cfgServerPowerLastWeekMaxPower Max.
Legacy Groups and Objects New Groups and Objects cfgUserAdminUserName UserName cfgUserAdminPassword Password cfgUserAdminEnable Enable cfgUserAdminPrivilege Privilege cfgUserAdminIpmiLanPrivilege IpmiLanPrivilege cfgUserAdminIpmiSerialPrivilege IpmiSerialPrivilege cfgUserAdminSolEnable SolEnable cfgRemoteHosts iDRAC.SysLog cfgRhostsSyslogEnable SysLogEnable cfgRhostsSyslogServer1 Server1 cfgRhostsSyslogServer2 Server2 cfgRhostsSyslogServer3 Server3 cfgRhostsSyslogPort Port iDRAC.
Legacy Groups and Objects New Groups and Objects Port Timeout cfgSsnMgtRacadmTimeout iDRAC.Racadm Enable Timeout cfgSsnMgtConsRedirMaxSessions iDRAC.VirtualConsole EncryptEnable Enable PluginType LocalVideo Port MaxSessions Timeout AccessPrivilege cfgSsnMgtWebserverTimeout iDRAC.Webserver Enable HttpPort Timeout HttpsPort LowerEncryptionBitLength [cfgSerial] iDRAC.
Legacy Groups and Objects New Groups and Objects cfgSerialTelnetEnable iDRAC.Telnet cfgSerialSshEnable iDRAC.SSH [cfgOobSnmp] iDRAC.SNMP cfgOobSnmpAgentEnable AgentEnable cfgOobSnmpAgentCommunity AgentCommunity [cfgNetTuning] cfgNetTuningNic100MB iDRAC.Nic cfgNetTuningNicFullDuplex iDRAC.Nic cfgNetTuningNicMtu iDRAC.Nic cfgNetTuningNicAutoneg iDRAC.Nic [cfgRacTuning] cfgRacTuneRemoteRacadmEnable=1 iDRAC.Racadm cfgRacTuneWebserverEnable=1 iDRAC.Webserver cfgRacTuneHttpPort=80 iDRAC.
Legacy Groups and Objects New Groups and Objects cfgRacTuneCtrlEConfigDisable=0 PrebootConfig cfgRacTuneLocalConfigDisable=0 LocalConfig cfgRacTuneVirtualConsoleAuthorizeMultipleSessions=0 iDRAC.VirtualConsole ifcRacManagedNodeOs System.ServerOS ifcRacMnOsHostname HostName ifcRacMnOsOsName OSName cfgRacSecurity iDRAC.
Legacy Groups and Objects New Groups and Objects cfgLdapRoleGroup iDRAC.LDApRole cfgLdapRoleGroupIndex NA cfgLdapRoleGroupDN DN cfgLdapRoleGroupPrivilege Privilege cfgStandardSchema iDRAC.ADGroup cfgSSADRoleGroupIndex NA cfgSSADRoleGroupName Name cfgSSADRoleGroupDomain Domain cfgSSADRoleGroupPrivilege Privilege cfgIpmiSerial iDRAC.
Legacy Groups and Objects New Groups and Objects cfgIpmiPetCommunityName CommunityName cfgUserDomain iDRAC.UserDomain cfgUserDomainIndex NA cfgUserDomainName Name cfgSmartCard iDRAC.SmartCard cfgSmartCardLogonEnable SmartCardLogonEnable cfgSmartCardCRLEnable SmartCardCRLEnable [cfgIPv6URL] cfgIPv6URLString NA cfgVFlashSD iDRAC.
Legacy Groups and Objects New Groups and Objects iDRAC.SNMP.Alert cfgIpmiPetAlertEnable Enable cfgIpmiPetAlertDestIpAddr DestAddr Topics: • cfgSSADRoleGroupPrivilege (Read or Write) cfgSSADRoleGroupPrivilege (Read or Write) Table 1270. Details of cfgSSADRoleGroupPrivilege Description Use the bit mask numbers listed in the table below to set role-based authority privileges for a Role Group.