Users Guide

Table Of Contents
Troubleshooting RAID
RAID configuration using PERC
How to create RAID volumes
If your system has one or more supported PERC RAID controllers with PERC 8 firmware or later versions, or software RAID
controllers, use the RAID Configuration wizard to configure a virtual disk as the boot device. RAID volumes can be created using
several interfaces. Here we are creating a RAID volume using Lifecycle controller.
To configure RAID using LC, complete the following steps:
1. Start Lifecycle Controller. For more information, see Lifecycle Controller User's Guide available at https://www.dell.com/
idracmanuals .
2. In the left pane, click Hardware Configuration.
3. In the right pane, click Configuration wizards.
4. Under Storage configuration wizard, click RAID configuration to launch the wizard.
The View Current RAID Configuration and Select Controller page is displayed.
NOTE: BOSS-S1 controller is supported at RAID 1 level only.
5. Select the controller which you want to use and click Next.
The Select RAID Level page is displayed.
6. Select the RAID level and click Next.
The Select Physical Disks page is displayed.
7. Select the physical disk and click Next.
The Virtual Disk Attributes page is displayed.
8. Select the virtual disk parameters and click Next.
The Summary page is displayed.
9. To apply the RAID configuration, click Finish.
For more information about creating a RAID using other interfaces, see Lifecycle Controller User's Guide available at https://
www.dell.com/idracmanuals
Creating a secured virtual disk
A virtual disk can be either secured or unsecured depending on how it was configured when created. The Dell PowerEdge RAID
Controller (PERC) cards support Self-Encrypting Disks (SED) for protection of data against loss or theft of SEDs.
Prerequisites
The controller must have a security key present and must contain SEDs only.
About this task
To create a secured virtual disk, do the following:
Steps
1. During host system bootup, press Ctrl + R after the BIOS screen is displayed.
The Virtual Disk Management screen is displayed. If there is more than one controller, the main menu screen is displayed.
Select a controller, and press Enter. The Virtual Disk Management screen is displayed for the selected controller.
2. Use the arrow keys to highlight the PERC series of adapters.
For example, PERC H730P Adapter or Disk Group #.
3. Press F2.
A list of available actions is displayed.
64