Owners Manual
Table Of Contents
- Dell EMC PowerEdge R6515 Installation and Service Manual
- About this document
- PowerEdge R6515 system overview
- Initial system setup and configuration
- Installing and removing system components
- Safety instructions
- Before working inside your system
- After working inside your system
- Recommended tools
- Optional front bezel
- System cover
- Drive backplane cover
- Air shroud
- Cooling fan
- Intrusion switch module
- Drives
- Drive backplane
- Cable routing
- System memory
- Processor and heat sink
- Expansion cards and expansion card risers
- Micro SD card
- M.2 SSD module
- Optional IDSDM module
- LOM riser card
- Mini PERC card
- System battery
- Optional internal USB memory key
- VGA module
- Optional optical drive
- Power supply unit
- Power interposer board
- System board
- Trusted Platform Module
- Control panel
- Jumpers and connectors
- System diagnostics and indicator codes
- Getting help
- Documentation resources

2. Follow the procedure listed in the After working inside your system.
Expansion cards and expansion card risers
NOTE: A system event entry is logged in the iDRAC Lifecycle Controller if an expansion card riser is not supported or
missing. It does not prevent your system from turning on. However, if a F1/F2 pause occurs with an error message,
see Troubleshooting expansion cards section in the Dell EMC PowerEdge Servers Troubleshooting Guide at www.dell.com/
poweredgemanuals.
Expansion card installation guidelines
The following table describes the supported expansion cards:
Table 17. Expansion card riser configurations
Expansion card
riser
PCIe slots on the
riser
Processor
connection
Height Length Slot width
No riser
Slot 1 Processor 1 NA NA x8
Riser 1A
Slot 2 Processor 1 Low Profile Half Length x16
Riser 2
Slot 3 Processor 1 Low Profile Half Length x16
NOTE: The expansion-card slots are not hot-swappable.
The following table provides guidelines for installing expansion cards to ensure proper cooling and mechanical fit. The expansion
cards with the highest priority should be installed first using the slot priority indicated. All the other expansion cards should be
installed in the card priority and slot priority order.
Table 18. No riser configuration (Slot 1)
Card type Slot priority Maximum number of cards
PERC 9: Mini mono (H730P/H330) Integrated slot 1
PERC 10: Mini mono (H740P) Integrated slot 1
HBA: Mini mono (HBA330) Integrated slot 1
LOM riser ( 2x1 G)/(2x10 G)/(2x25 G) 1 1
Table 19. Riser configuration (include slots 1 and 3)
Card type Slot priority Maximum number of cards
PERC 9: Mini mono (H730P/H330) Integrated slot 1
PERC 10: Mini mono (H740P) Integrated slot 1
HBA: Mini mono (HBA330) Integrated slot 1
PERC 10: External adapter (H840) 3 1
PERC 10: External adapter (H840) (FH
or LP)
3 1
PERC 11: External adapter (HBA355E) 3 1
HBA: External adapter 3 1
NVME PCIE SSD 3 1
Broadcom (1 G QP) 3 1
Broadcom (10 G DP) 3 1
60 Installing and removing system components