Dell EMC PowerEdge R6515 Technical Specifications Regulatory Model: E45S Regulatory Type: E45S003 June 2021 Rev.
Notes, cautions, and warnings NOTE: A NOTE indicates important information that helps you make better use of your product. CAUTION: A CAUTION indicates either potential damage to hardware or loss of data and tells you how to avoid the problem. WARNING: A WARNING indicates a potential for property damage, personal injury, or death. © 2019- 2021 Dell Inc. or its subsidiaries. All rights reserved. Dell, EMC, and other trademarks are trademarks of Dell Inc. or its subsidiaries.
Contents Chapter 1: Technical specifications............................................................................................... 4 Chassis dimensions............................................................................................................................................................. 5 System weight......................................................................................................................................................................
1 Technical specifications The technical and environmental specifications of your system are outlined in this section.
Chassis dimensions Figure 1. Chassis dimensions Table 1. PowerEdge R6515 chassis dimensions Zb * System configurations Xa Xb Y Za 4 x 3.5-inches or 10 x 2.5inches 482.0 mm 434.0 mm 42.8 mm 657.25 mm With bezel: 35.84 mm (1.4 (25.87 inches) inches) Without bezel: 22.0 mm (0.87 inches) 692.62 mm 8 x 2.5-inches 482.0 mm 606.47 mm With bezel: 35.84 mm (1.4 (23.87 inches) inches) Without bezel: 22.0 mm (0.87 inches) 641.85 mm (18.97 inches) (17.08 inches) (1.68 inches) 434.0 mm 42.8 mm (18.
System weight Table 2. PowerEdge R6515 system weight System configuration Maximum weight (with all drives) 4 x 3.5-inch configuration 16.75 kg (36.92 lb) 8 x 2.5-inch configuration 15.6 kg (34.39 lb) 10 x 2.5-inch configuration 15.8 kg (34.83 lb) Processor specifications Table 3. PowerEdge R6515 processor specifications Supported processor Number of processors supported AMD EYPC 7002 and 7003 series processor One PSU specifications Table 4.
NOTE: The STD and HPR fans installation depends on the system configuration. For more information about the fan support configuration or matrix, see Thermal restriction matrix. System battery specifications The PowerEdge R6515 system supports CR 2032 3.0-V lithium coin cell system battery. Expansion card riser specifications WARNING: Consumer-Grade GPU should not be installed or used in the Enterprise Server products.
Table 8. PowerEdge R6515 system controller cards Internal controllers External controllers ● Boot Optimized Storage Subsystem (BOSS-S1): HWRAID 2 x M.2 SSDs Drive specifications Drives The PowerEdge R6515 system supports ● Up to 4 x 3.5-inch (SAS, SATA or SSD) front accessible drives in slot 0 to 3 ● Up to 8 x 2.5-inch (SAS, SATA or SSD) front accessible drives in slot 0 to 7 ● Up to 10 x 2.
LOM riser card specifications The PowerEdge R6515 system supports up to two 10/100/1000 Mbps Network Interface Controller (NIC) ports that are located on the back panel. The system also supports LAN on Motherboard (LOM) on an optional riser card. You can install one LOM riser card. The supported LOM riser options are: ● ● ● ● 2 x 1 Gb Base-T 2 x 10Gb Base-T 2 x 10Gb SFP+ 2 x 25Gb SFP+ NOTE: ● You can install up to two PCIe add-on NIC cards.
Table 12.
Shared requirements across all categories Table 15. Shared requirements across all categories Allowable operations Maximum temperature gradient (applies to both operation and 20°C in an hour* (36°F in an hour) and 5°C in 15 minutes nonoperation) (9°F in 15 minutes), 5°C in an hour* (9°F in an hour) for tape hardware Nonoperational temperature limits -40°C-65°C (-40°F-149°F) Nonoperational humidity limits 5% to 95% RH with 27°C (80.
Table 18. Particulate contamination specifications (continued) Particulate contamination Specifications NOTE: This condition applies to data center and non-data center environments. NOTE: Common sources of conductive dust include manufacturing processes, and zinc whiskers from the plating on the bottom of raised floor tiles. ● Air must be free of corrosive dust. ● Residual dust present in the air must have a deliquescent point less than 60% relative humidity.
NOTE: For 10 x 2.5-inch drives (NVMe), maximum supported ambient temperature is 30°C. Table 21. Thermal restriction matrix for T4 GPGPU Riser configurations Configuration type and ambient temperature support 4 x 3.5-inch drives 8 x 2.5-inch drives 10 x 2.5-inch drives (NVMe) 2 LP 2 LP 2 LP Ambient = 30°C Slot 2 HPR fan HPR fan NA Slot 3 HPR fan HPR fan HPR fan + NVMe drives from slot 6-9 + SAS or SATA drives from slot 0-5 Table 22.