Specifications

Dell
PowerEdge R715 Technical Guide 38
11 Storage
11.1 Overview
Table 12 lists the hard drives supported by the R715. Table 13 lists the supported RAID
configurations.
Table 12. Supported Hard Drives
Form Factor
Capacity
Speed
Type
2.5‖
50, 100 GB
SSD (SATA)
2.5‖
160, 250, 500 GB
7.2K
3Gb SATA
2.5‖
500 GB
7.2K
6Gb Near-line SAS
2.5‖
146, 300 GB
10K
6Gb SAS
2.5‖
73, 146 GB
15K
6Gb SAS
Table 13. RAID Configurations
Non-Mixed drives
all SATA or all SAS or
all SSD
Config Type
Configs
Description
Min HDD
Max HDD
No HDD
0
NZC
No controller/No hard drive
2.5‖ = 0
2.5‖ = 0
SAS or SATA
HDDs,
SAS or SATA
SSDsNo
RAID
1
MSS
Integrated SAS/SATA: PERC H200, No RAID
2.5‖ = 1
2.5‖ = 6
SAS or SATA
HDDs,
SAS or SATA
SSDsRAID
2
MSSR0
Integrated SAS/SATA RAID 0 ( PERC H700,PERC H200)
2.5‖ = 2
2.5‖ = 6
3
MSSR1
Integrated SAS/SATA RAID 1 (PERC H700,PERC H200)
2.5‖ = 2
2.5‖ = 2
4
MSSR5
Integrated SAS/SATA RAID 5 ( PERC H700)
2.5‖ = 3
2.5‖ = 6
5
MSSR1/R5
Integrated SAS/SATA RAID 1/RAID 5 (PERC H700)
2.5‖ = 2+3
2.5‖ = 2+4
6
MSSR10
Integrated SAS/SATA RAID 10 (PERC H700, PERC H200)
2.5‖ = 4
2.5‖ = 6