User Guide
Table Of Contents
- Dell PowerEdge R720 and R720xd Owner's Manual
- About Your System
- Using The System Setup and Boot Manager
- Installing System Components
- Recommended Tools
- Front Bezel (Optional)
- Opening And Closing The System
- Inside The System
- Cooling Shroud
- System memory
- Hard Drives
- Removing A 2.5 Inch Hard-Drive Blank
- Installing A 2.5 Inch Hard-Drive Blank
- Removing A 2.5 Inch Hard-Drive Blank (Back)
- Installing A 2.5 Inch Hard-Drive Blank (Back)
- Removing A 3.5 Inch Hard-Drive Blank
- Installing A 3.5 Inch Hard-Drive Blank
- Removing A Hot-Swap Hard Drive
- Installing A Hot-Swap Hard Drive
- Removing A Hard Drive From A Hard-Drive Carrier
- Installing A Hard Drive Into A Hard-Drive Carrier
- Optical Drive (Optional)
- Cooling Fans
- Internal USB Memory Key (Optional)
- PCIe Card Holder
- Top Cover Lock Latch
- Cable Retention Bracket
- Expansion Cards And Expansion-Card Risers
- Expansion Card Installation Guidelines
- Removing An Expansion Card From The Expansion-Card Riser 2 Or 3
- Installing An Expansion Card Into The Expansion-Card Riser 2 Or 3
- Removing An Expansion Card From The Expansion-Card Riser 1
- Installing An Expansion Card Into The Expansion-Card Riser 1
- Removing Expansion-Card Risers
- Installing Expansion-Card Risers
- GPU Card Installation Guidelines
- Installing A GPU Card
- Removing A GPU Card
- SD vFlash Card
- Internal Dual SD Module
- Internal SD Card
- Integrated Storage Controller Card
- Network Daughter Card
- Processors
- Power Supplies
- System Battery
- Hard-Drive Backplane
- Control Panel Board
- System Board
- Troubleshooting Your System
- Safety First—For You And Your System
- Troubleshooting System Startup Failure
- Troubleshooting External Connections
- Troubleshooting The Video Subsystem
- Troubleshooting A USB Device
- Troubleshooting A Serial I/O Device
- Troubleshooting A NIC
- Troubleshooting A Wet System
- Troubleshooting A Damaged System
- Troubleshooting The System Battery
- Troubleshooting Power Supplies
- Troubleshooting Cooling Problems
- Troubleshooting Cooling Fans
- Troubleshooting System Memory
- Troubleshooting An Internal USB Key
- Troubleshooting An SD Card
- Troubleshooting An Optical Drive
- Troubleshooting A Tape Backup Unit
- Troubleshooting A Hard Drive
- Troubleshooting A Storage Controller
- Troubleshooting Expansion Cards
- Troubleshooting Processors
- Using System Diagnostics
- Jumpers And Connectors
- Technical Specifications
- System Messages
- Getting Help

Electrical indicator
Condition Corrective Action
The indicator blinks
amber if the system
experiences an
electrical error (for
example, voltage out
of range, or a failed
power supply or
voltage regulator).
See the System Event Log or system messages for the specific issue.
If it is due to a problem with the power supply, check the LED on the
power supply. Re-seat the power supply by removing and reinstalling
it. If the problem persists, see Getting Help.
Temperature indicator
Condition Corrective Action
The indicator blinks
amber if the system
experiences a
thermal error (for
example, a
temperature out of
range or fan failure).
Ensure that none of the following conditions exist:
• A cooling fan is removed or has failed.
• System cover, cooling shroud, EMI filler panel, memory-module
blank, or back-filler bracket is removed.
• Ambient temperature is too high.
• External airflow is obstructed.
See Getting Help.
Memory indicator
Condition Corrective Action
The indicator blinks
amber if a memory
error occurs.
See the system event log or system messages for the location of the
failed memory. Reinstall the memory device. If the problem persists,
see Getting Help.
PCIe indicator
Condition Corrective Action
The indicator blinks
amber if a PCIe card
experiences an
error.
Restart the system. Update any required drivers for the PCIe card.
Re-install the card. If the problem persists, see Getting Help.