Users Guide

Table Of Contents
Table 52. Supported features of storage controllers for MX platforms (continued)
Feature PERC 10 PERC 9
H745P MX H730P MX
Securely erase the data for PCIe
SSD
Not applicable Not applicable
Configure Backplane mode (split/
unified)
Not applicable Not applicable
Blink or unblink component LEDs Real-time Real-time
Switch Controller Mode Not applicable Staged
T10PI Support for Virtual Disks Not applicable Not applicable
Table 53. Supported features for storage devices
Feature PCIe SSD BOSS
Create Virtual Disks Not applicable Staged
Reset Controller Configuration Not applicable Staged
Fast Initialization Not applicable Staged
Delete Virtual Disks Not applicable Staged
Full Initialization Not applicable Not applicable
Inventory and remotely monitor the
health of PCIe SSD devices
Real-time Not applicable
Prepare the PCIe SSD to be removed Real-time Not applicable
Securely erase the data for PCIe SSD Staged Not applicable
Blink or unblink component LEDs Real-time Not applicable
Inventorying and monitoring storage devices
You can remotely monitor the health and view the inventory of the following Comprehensive Embedded Management (CEM)
enabled storage devices in the managed system using iDRAC web interface:
RAID controllers, non-RAID controllers, BOSS controllers and PCIe extenders
Enclosures that include Enclosure Management Modules (EMMs), power supply, fan probe, and temperature probe
Physical disks
Virtual disks
Batteries
The recent storage events and topology of storage devices are also displayed.
Alerts and SNMP traps are generated for storage events. The events are logged in the Lifecycle Log.
NOTE:
For an accurate inventory of BOSS controllers, ensure that Collect System Inventory On Reboot Operation (CSIOR)
is completed. CSIOR is enabled by default.
NOTE: If you enumerate the enclosure view's WSMan command on a system while one PSU-cable is removed, the primary
status of the enclosure view is reported as Healthy instead of Warning.
NOTE: The storage health rollup follows the same convention of Dell EMC OpenManage product. For more information see
the OpenManage Server Administrator User's Guide available at www.dell.com/openmanagemanuals.
NOTE: Physical disks in system with multiple backplanes may be listed under a different backplane. Use the blink function
to identify the disks.
Managing storage devices 215