USB NIC The OS to iDRAC pass-through link between the iDRAC and the host operating system is established
through the internal USB bus.
NOTE: If you set the pass-through mode to LOM, ensure that:
OS and iDRAC are on the same subnet
NIC selection in Network Settings is set to LOM
4. If you select LOM as the pass-through configuration, and if the server is connected using dedicated mode, enter the IPv4
address of the operating system.
NOTE: If the server is connected in shared LOM mode, then the OS IP Address field is disabled.
NOTE: If the VLAN is enabled on the iDRAC, the LOM-Passthrough will only function in shared LOM mode with VLAN
tagging configured on the host.
5. If you select USB NIC as the pass-through configuration, enter the IP address of the USB NIC.
The default value is 169.254.1.1. It is recommended to use the default IP address. However, if this IP address conflicts with
an IP address of other interfaces of the host system or the local network, you must change it.
Do not enter 169.254.0.3 and 169.254.0.4 IPs. These IPs are reserved for the USB NIC port on the front panel when a A/A
cable is used.
6. Click Apply.
7. Click Test Network Configuration to check if the IP is accessible and the link is established between the iDRAC and the
host operating system.
Enabling or disabling OS to iDRAC Pass-through using RACADM
To enable or disable OS to iDRAC Pass-through using RACADM, use the objects in the iDRAC.OS-BMC group.
For more information, see the iDRAC RACADM CLI Guide available at www.dell.com/idracmanuals.
Enabling or disabling OS to iDRAC Pass-through using iDRAC
settings utility
To enable or disable OS to iDRAC Pass-through using iDRAC Settings Utility:
1. In the iDRAC Settings utility, go to Communications Permissions.
The iDRAC Settings.Communications Permissions page is displayed.
2. Select any of the following options to enable OS to iDRAC pass-through:
LOM The OS to iDRAC pass-through link between the iDRAC and the host operating system is established through
the LOM or NDC.
USB NIC The OS to iDRAC pass-through link between the iDRAC and the host operating system is established
through the internal USB bus.
NOTE:
If you set the pass-through mode to LOM, ensure that:
OS and iDRAC are on the same subnet
NIC selection in Network Settings is set to a LOM
To disable this feature, select Disabled.
NOTE:
The LOM option can be selected only of the card supports OS to iDRAC pass-through capability. Else, this
option is grayed-out.
3. If you select LOM as the pass-through configuration, and if the server is connected using dedicated mode, enter the IPv4
address of the operating system.
NOTE: If the server is connected in shared LOM mode, then the OS IP Address field is disabled.
4. If you select USB NIC as the pass-through configuration, enter the IP address of the USB NIC.
The default value is 169.254.1.1. However, if this IP address conflicts with an IP address of other interfaces of the host
system or the local network, you must change it. Do not enter 169.254.0.3 and 169.254.0.4 IPs. These IPs are reserved for
the USB NIC port on the front panel when a A/A cable is used
98
Configuring iDRAC