Owner's Manual
Table Of Contents
- Dell PowerEdge R920 System Owner's Manual
- About Your System
- Using The System Setup and Boot Manager
- Installing System Components
- Recommended Tools
- Front Bezel (Optional)
- Opening And Closing The System
- Inside The System
- Cable Management Tray
- System Memory
- General Memory Module Installation Guidelines
- Mode-Specific Guidelines
- Advanced ECC (Lockstep)
- Memory Optimized (Independent Channel) Mode
- Memory Sparing
- Memory Mirroring
- Fault Resilient Memory
- Sample Memory Configurations
- Removing A Memory-Riser Blank
- Installing A Memory-Riser Blank
- Removing A Memory Riser
- Installing A Memory Riser
- Removing Memory Modules From The Memory Riser
- Installing Memory Modules
- Memory Riser And Fan Cage
- Hard Drives
- Optical Drive (Optional)
- Cooling Fans
- Internal USB Memory Key (Optional)
- Expansion Cards And Expansion-Card Risers
- Expansion Card Installation Guidelines
- Removing The Left Expansion Card Riser Blank
- Installing The Left Expansion Card Riser Blank
- Removing The Right Expansion Card Riser Blank
- Removing An Expansion Card From Expansion-Card Risers 2 and 3
- Installing An Expansion Card Into The Expansion-Card Riser 2 and 3
- NDC Riser (I/O Riser 1)
- Network Daughter Card
- SD vFlash Card
- Internal Dual SD Module
- Internal SD Card
- Integrated Storage Controller Card
- RAID Battery
- Processors
- Power Supplies
- Hot Spare Feature
- Removing An AC Power Supply
- Installing An AC Power Supply
- Wiring Instructions For A DC Power Supply
- Assembling And Connecting The Safety Ground Wire
- Assembling The DC Input Power Wires
- Removing A DC Power Supply
- Installing A DC Power Supply
- Removing The Power Supply Blank
- Installing The Power Supply Blank
- Power Distribution Board
- System Battery
- Hard-Drive Backplane
- SAS Expander Daughter Card
- Control Panel Board
- System Board
- Troubleshooting Your System
- Safety First—For You And Your System
- Troubleshooting System Startup Failure
- Troubleshooting External Connections
- Troubleshooting The Video Subsystem
- Troubleshooting A USB Device
- Troubleshooting A Serial I/O Device
- Troubleshooting A Wet System
- Troubleshooting A Damaged System
- Troubleshooting The System Battery
- Troubleshooting Power Supplies
- Troubleshooting Cooling Problems
- Troubleshooting Cooling Fans
- Troubleshooting System Memory
- Troubleshooting An Internal USB Key
- Troubleshooting An SD Card
- Troubleshooting An Optical Drive
- Troubleshooting A Hard Drive
- Troubleshooting A Storage Controller
- Troubleshooting Expansion Cards
- Troubleshooting Processors
- Using System Diagnostics
- Jumpers And Connectors
- Technical Specifications
- System Messages
- Getting Help

Cable Management Tray
The cable management tray is located above the processor heat sinks. It is used to route and manage the cables
connecting the storage and expansion cards to various connectors on the backplane.
NOTE: Cable management tray also facilitates in maintaining the proper cooling of the system. It helps control
airflow to the processors and the expansion-cards on risers, when the risers are installed.
Removing The Cable Management Tray
1. Turn off the system, including any attached peripherals, and disconnect the system from the electrical outlet.
2. Open the system.
3. Remove the memory risers. See Removing a Memory Riser.
4. Remove the cooling fans. See Removing A Cooling Fan.
5. Remove the memory riser and fan cage. See Removing the Memory Riser and Fan cage.
6. To open the cable tray cover, press the release tab.
7. Remove the cables routed through the cable tray.
8. Press down on the cable tray hooks to free them of the slots on the side of the chassis wall.
9. Lift the cable tray out of the system.
Figure 13. Removing and Installing the Cable Management Tray
1.
cable tray slot (4) 2. cable tray hook (4)
3. cable tray cover 4. cable tray cover release tab
5. cables (routed)
38