Users Guide

选项 说明
如果已创建虚拟磁盘,则会显示此选项。
启用自动导入
无需访问 BIOS 配置公用程序 (<Ctrl> <R>),便可在引导过程中
尝试导入每个联机外部配置。
出厂默认设置
选择此选项可还原设置框中各选项的默认设置。
个性化模式
选择此选项以切换到 HBA 模式。默认模式为 RAID 模式。
已占用高速缓存数据错误消息
错误消息:
The following virtual disks are missing: (x). If you proceed (or load the
configuration utility), these virtual disks will be removed from your
configuration. If you wish to use them at a later time, they will have to be
imported. If you believe these virtual disks should be present, please power
off your system and check your cables to ensure all disks are present. Press
any key to continue, or 'C' to load the configuration utility. The cache
contains dirty data, but some virtual disks are missing or will go offline, so
the cached data cannot be written to disk. If this is an unexpected error, then
please power off your system and check your cables to ensure all disks are
present. If you continue, the data in cache will be permanently discarded.
Press 'X' to acknowledge and permanently destroy the cached data.
可能的原因: 如果虚拟磁盘由于缺失物理磁盘而处于脱机状态或被删除,则控制器将保留该虚拟磁盘中的已占用高速缓
存。此消息表示已卸下某些已配置磁盘。如果没有卸下磁盘,则这些磁盘不再可访问。系统的 SAS 电缆可能
连接不正确。
纠正措施:
检查电缆连接并修复任何问题。重新启动系统。使用 <Ctrl> <R> 公用程序导入虚拟磁盘或者放弃已保留的高
速缓存。有关管理保留的高速缓存的步骤,请参阅管理保留的高速缓存
查找错误消息
错误消息:
A discovery error has occurred, please power cycle the system and all the
enclosures attached to this system.
可能的原因:
此消息表明未能在 120 秒内完成查找。系统的 SAS 电缆可能连接不正确。
纠正措施: 检查电缆连接并修复任何问题。重新启动系统。
驱动器配置更改错误消息
错误消息:
Entering the configuration utility in this state will result in drive
configuration changes. Press 'Y' to continue loading the configuration utility
or please power off your system and check your cables to ensure all disks are
present and reboot.
可能的原因:
另一个 BIOS 警告提示之前配置的磁盘存在问题并且您选择接受所有更改并继续之后,则会显示此消息。系统
SAS 电缆可能连接不正确。
纠正措施:
检查电缆连接并修复任何问题,然后重新启动系统。如果电缆没有问题,请按任意键或 <Y> 键继续。
88