Reference Guide
Table Of Contents
- Dell EMC PowerEdge RAID Controller Command Line Interface Reference Guide
- Contents
- Overview
- Accessing the command prompt
- Working with the PERC Command Line Interface Tool
- System commands
- Controller commands
- Drive commands
- Virtual drives commands
- Add virtual drives commands
- Delete virtual drives commands
- Delete non-RAID disks
- Virtual drive show commands
- Preserved cache commands
- Change virtual drive properties commands
- Virtual drive initialization commands
- Virtual drive erase commands
- Virtual drive migration commands
- Virtual drive consistency check commands
- Background initialization commands
- Foreign configurations commands
- BIOS-related commands
- Drive group commands
- BBU commands
- Enclosure commands
- PHY commands
- Logging commands
- PERC CLI command examples
- Getting a complete list of CLI commands
- Checking controller availability
- Viewing controllers
- Viewing free space information
- Viewing disk1 information
- Viewing controller, virtual disk, and drivers information
- Checking for preserved cache
- Deleting preserved cache
- Viewing expansion information
- Viewing expansion size
- Viewing the foreign configuration
- Importing the foreign configuration
- Viewing BBU information
- Viewing physical drive details for the specified slot in the controller
- Viewing the boot drive for the controller
- Setting virtual drive as boot drive
- Locating a drive
- Stopping a locate operation
- Snapdump commands
- Getting help
- Documentation resources
DG/VD Type State Access Consist Cache sCC Size Name
------------------------------------------------------------------
0/0 RAID5 Opt1 RW Yes RWTD - 1.635 TB
1/1 RAID0 Opt1 RW Yes RWTD - 558.375 GB Test
------------------------------------------------------------------
Physical Drives = 9
PD LIST :
=======
-------------------------------------------------------------------------
EID:Slt DID State DG Size Intf Med SED PI SeSz Model Sp
-------------------------------------------------------------------------
32:0 0 Onln 0 558.375 GB SAS HDD Y Y 4 KB ST600MP0084 U
32:1 1 Onln 0 558.375 GB SAS HDD Y Y 4 KB ST600MP0084 U
32:2 2 Onln 1 558.375 GB SAS HDD Y N 512B ST600MP0054 U
32:3 3 Onln 0 558.375 GB SAS HDD Y Y 4 KB ST600MP0084 U
32:4 4 Onln 0 558.375 GB SAS HDD Y Y 4 KB ST600MP0084 U
32:5 5 UGood - 558.375 GB SAS HDD N N 512B ST600MP0034 U
32:6 6 UGood - 558.375 GB SAS HDD Y N 512B ST600MP0054 U
32:7 7 UGood - 558.375 GB SAS HDD N N 512B ST600MP0034 U
32:18 18 UGood - 558.375 GB SAS HDD Y N 512B ST600MP0054 U
-------------------------------------------------------------------------
Cachevault_info :
===============
-------------------------------------
Model State Temp Mode MfgDate
-------------------------------------
BBU Failed 76C - 2011/07/18
-------------------------------------
Checking for preserved cache
Syntax
perccli /c0 show preservedcache
Description
Displays available preserved cache.
Result
Controller = 0
Status = Success
Description = None
------------
VD State
------------
0 Missing
------------
Working with the PERC Command Line Interface Tool