Reference Guide
Table Of Contents
- Dell EMC PowerEdge RAID Controller Command Line Interface Reference Guide
- Contents
- Overview
- Accessing the command prompt
- Working with the PERC Command Line Interface Tool
- System commands
- Controller commands
- Drive commands
- Virtual drives commands
- Add virtual drives commands
- Delete virtual drives commands
- Delete non-RAID disks
- Virtual drive show commands
- Preserved cache commands
- Change virtual drive properties commands
- Virtual drive initialization commands
- Virtual drive erase commands
- Virtual drive migration commands
- Virtual drive consistency check commands
- Background initialization commands
- Foreign configurations commands
- BIOS-related commands
- Drive group commands
- BBU commands
- Enclosure commands
- PHY commands
- Logging commands
- PERC CLI command examples
- Getting a complete list of CLI commands
- Checking controller availability
- Viewing controllers
- Viewing free space information
- Viewing disk1 information
- Viewing controller, virtual disk, and drivers information
- Checking for preserved cache
- Deleting preserved cache
- Viewing expansion information
- Viewing expansion size
- Viewing the foreign configuration
- Importing the foreign configuration
- Viewing BBU information
- Viewing physical drive details for the specified slot in the controller
- Viewing the boot drive for the controller
- Setting virtual drive as boot drive
- Locating a drive
- Stopping a locate operation
- Snapdump commands
- Getting help
- Documentation resources
Property Value
----------------------
Type BBU
Voltage 3 mV
Current 0 mA
Temperature 32 C
Battery State Optimal
----------------------
BBU_Firmware_Status :
===================
-------------------------------------------------
Property Value
-------------------------------------------------
Charging Status None
Voltage OK
Temperature OK
Learn Cycle Requested No
Learn Cycle Active No
Learn Cycle Status OK
Learn Cycle Timeout No
I2C Errors Detected No
Battery Pack Missing No
Replacement required No
Remaining Capacity Low No
Periodic Learn Required No
Transparent Learn No
No space to cache offload No
Pack is about to fail & should be replaced No
Cache Offload premium feature required No
Module microcode update required No
-------------------------------------------------
GasGaugeStatus :
==============
-------------------------------------
Property Value
-------------------------------------
Fully Discharged Yes
Fully Charged Yes
Discharging No
Initialized No
Remaining Time Alarm No
Remaining Capacity Alarm Yes
Terminate Discharge Alarm No
Over Temperature No
Charging Terminated No
Over Charged No
Relative State of Charge 100%
Charger System State Complete
Remaining Capacity 407
Full Charge Capacity 407
Is SOH Good Yes
Battery backup charge time 0 hour(s)
-------------------------------------
BBU_Capacity_Info :
=================
------------------------------------------------------
Property Value
------------------------------------------------------
Relative State of Charge 100%
Absolute State of charge 0%
Remaining Capacity 407 mAh
Full Charge Capacity 407 mAh
Run time to empty Battery is not being charged
Average time to empty 33 min
Average Time to full Battery is not being charged
Cycle Count 3
Max Error 0%
Remaining Capacity Alarm 0 mAh
Remaining Time Alarm 0 minutes(s)
------------------------------------------------------
Working with the PERC Command Line Interface Tool
57