Reference Guide
Table Of Contents
- Dell EMC PowerEdge RAID Controller Command Line Interface Reference Guide
- Contents
- Overview
- Accessing the command prompt
- Working with the PERC Command Line Interface Tool
- System commands
- Controller commands
- Drive commands
- Virtual drives commands
- Add virtual drives commands
- Delete virtual drives commands
- Delete non-RAID disks
- Virtual drive show commands
- Preserved cache commands
- Change virtual drive properties commands
- Virtual drive initialization commands
- Virtual drive erase commands
- Virtual drive migration commands
- Virtual drive consistency check commands
- Background initialization commands
- Foreign configurations commands
- BIOS-related commands
- Drive group commands
- BBU commands
- Enclosure commands
- PHY commands
- Logging commands
- PERC CLI command examples
- Getting a complete list of CLI commands
- Checking controller availability
- Viewing controllers
- Viewing free space information
- Viewing disk1 information
- Viewing controller, virtual disk, and drivers information
- Checking for preserved cache
- Deleting preserved cache
- Viewing expansion information
- Viewing expansion size
- Viewing the foreign configuration
- Importing the foreign configuration
- Viewing BBU information
- Viewing physical drive details for the specified slot in the controller
- Viewing the boot drive for the controller
- Setting virtual drive as boot drive
- Locating a drive
- Stopping a locate operation
- Snapdump commands
- Getting help
- Documentation resources
BBU_Design_Info :
===============
-----------------------------------
Property Value
-----------------------------------
Date of Manufacture 18/07/2011
Design Capacity 90 mAh
Design Voltage 0 mV
Specification Info 0
Serial Number 0
Pack Stat Configuration 0
Manufacturer's Name
Device Name
Device Chemistry
Battery FRU N/A
Transparent Learn 1
App Data 0
Module Version 0.3
-----------------------------------
BBU_Properties :
==============
--------------------------------------------------------------
Property Value
--------------------------------------------------------------
Auto Learn Period 90d (7776000 seconds)
Next Learn time 2014/02/19 12:44:32 (446129072 seconds)
Learn Delay Interval 0 hour(s)
Auto-Learn Mode Transparent
--------------------------------------------------------------
Viewing physical drive details for the specified slot in the
controller
Syntax
perccli /c0/e32/s4 show all
Description
Displays information about the physical drive, including device attribute, settings, and port information for a particular slot in the
controller.
Result
Controller = 0
Status = Success
Description = Show Drive Information Succeeded.
Drive /c0/e32/s4:
================
-------------------------------------------------------------------------------
EID:Slt DID State DG Size Intf Med SED PI SeSz Model Sp
-------------------------------------------------------------------------------
32:4 4 Onln 0 558.375 GB SAS HDD Y Y 4 KB ST600MP0084 U
-------------------------------------------------------------------------------
EID-Enclosure Device ID|Slt-Slot No.|DID-Device ID|DG-Drive Group
DHS-Dedicated Hot Spare|UGood-Unconfigured Good|GHS-Global Hotspare
UBad-Unconfigured Bad|Onln-Online|Offln-Offline|Intf-Interface
Med-Media Type|SED-Self Encryption Drive|PI-Protection Info
SeSz-Sector Size|Sp-Spun|U-Up|D-Down|T-Transition|F-Foriegn
58
Working with the PERC Command Line Interface Tool