Remaining Capacity 407 mAh
Full Charge Capacity 407 mAh
Run time to empty Battery is not being charged
Average time to empty 33 min
Average Time to full Battery is not being charged
Cycle Count 3
Max Error 0%
Remaining Capacity Alarm 0 mAh
Remaining Time Alarm 0 minutes(s)
------------------------------------------------------
BBU_Design_Info :
===============
-----------------------------------
Property Value
-----------------------------------
Date of Manufacture 18/07/2011
Design Capacity 90 mAh
Design Voltage 0 mV
Specification Info 0
Serial Number 0
Pack Stat Configuration 0
Manufacturer's Name
Device Name
Device Chemistry
Battery FRU N/A
Transparent Learn 1
App Data 0
Module Version 0.3
-----------------------------------
BBU_Properties :
==============
--------------------------------------------------------------
Property Value
--------------------------------------------------------------
Auto Learn Period 90d (7776000 seconds)
Next Learn time 2014/02/19 12:44:32 (446129072 seconds)
Learn Delay Interval 0 hour(s)
Auto-Learn Mode Transparent
--------------------------------------------------------------
Viewing physical drive details for the specified slot in the
controller
Syntax
perccli /c0/e32/s4 show all
Description
Displays information about the physical drive, including device attribute, settings, and port information for a particular slot in the
controller.
Result
Controller = 0
Status = Success
Description = Show Drive Information Succeeded.
Drive /c0/e32/s4:
================