Users Guide

Figure 8. PERC H830 card ports
For information on unied mode, see the enclosure documentation that was shipped with the enclosure.
2 To add multiple enclosures, cable both out ports of the rst enclosure to both in ports of the next enclosure.
After you set up the hardware, the controller detects the redundant paths and automatically utilizes them to balance the I/O load.
Reverting to single path support from redundant path support
for PERC H830
If you need to revert to single path support from redundant path support, shut down the system and remove the exact same cables that
were added to support redundant path support, leaving only one connection between the controller and enclosures. After you remove the
cable and turn on the system, ensure that there are no warning messages during boot, and that all virtual disks are online and optimal.
240 virtual disk support for H830
As part of support for automatic conguration of each physical drive that is congured with RAID 0, H830 supports 240 virtual disks. The
number of supported virtual disks on H730 and H730P is 64.
24
Features