Users Guide
b Press <F2> to display the options Import and Clear.
NOTE: You must have all the drives in the system before you perform the import operation.
c Select Import to merge the foreign congurations with the existing conguration on the controller or Clear to delete the foreign
conguration(s) from the re-inserted disk(s).
If you select Import, all drives that were removed before the virtual disk became oine are imported, and then automatically
rebuilt.
NOTE: Start a consistency check immediately after the rebuild is complete to ensure data integrity for the
virtual disks. For more information about checking data consistency, see Checking Data Consistency .
3 If the physical disks in a non-redundant virtual disk are removed, the controller considers the disks to have foreign congurations.
Perform the following steps:
a Select Foreign Conguration View to display the complete foreign conguration information.
b Press <F2> to display the options Import and Clear.
c Select Import to import the foreign congurations to the virtual disk or Clear to delete the foreign conguration(s) from the re-
inserted disk(s).
No rebuilds occur after the import operation because there is no redundant data to rebuild the disks with.
Break mirror
A Break Mirror is performed only on RAID 1 arrays. It provides a way to 'split' the mirror and spin-down one of the hard disks, which can
then be imported into the conguration of a dierent PERC 9 series controller. This can be a useful way to:
• Create a disk image that can be imported and booted on a dierent system.
• Assist in software or conguration testing, where half of the mirror can be removed to ensure conguration consistency.
NOTE
: The Break Mirror operation is not available within the booted operating system environment. It is only available in
the BIOS Conguration Utility (<Ctrl> <R>) utility and the UEFI RAID conguration utility.
Break mirror in BIOS conguration utility
The RAID 1 virtual disk that you wish to split must be in an optimal state, and it cannot be running any other background tasks.
To use the Break Mirror feature, from the BIOS Conguration Utility Ctrl R, perform the following steps:
1 During boot up, press Ctrl R when prompted by the BIOS screen. If there is more than one controller in the system, choose the
controller.
The VD Mgmt screen is displayed by default.
2 Highlight the appropriate Disk Group
3 Press F2 to display the available actions.
4 Choose Break Mirror and press <Enter>.
A dialog box is displayed describing the operation and asking if you are sure you want to perform the operation.
5 Select Yes to continue.
The exported disk (exporting conguration) spins down and the hard drive status LED starts ashing to identify which drive must be
removed.
The remaining disk (exporting conguration) is in a degraded state until the missing member is replaced or rebuilt.
If there are any Global or Dedicated Hot Spare assigned, which fullls the rebuild requirements for the degraded RAID 1 disk, a rebuild
starts automatically. If there is no hot spare assigned, then an hot spare that meets all the requirements for the virtual disk must be
assigned before the rebuild starts.
BIOS