CLI Guide

cfgSerialCom2RedirEnable (Read or Write)
Table 168. Details of cfgSerialSshEnable
Description
Enables or disables the console for COM 2-port redirection.
The cfgSerialCom2RedirEnable object property is applicable only for iDRAC on Rack and Tower Servers.
Legal Values
1 (TRUE)
0 (FALSE)
Default
1
cfgSerialSshEnable (Read or Write)
Table 169. Details of cfgSerialSshEnable
Description
Enables or disables the secure shell (SSH) interface.
Legal Values
1 (TRUE)
0 (FALSE)
Default
1
Example
racadm getconfig -g cfgSerial
cfgSerialBaudRate=115200
cfgSerialConsoleEnable=1
cfgSerialConsoleQuitKey=^\
cfgSerialConsoleIdleTimeout=1800
cfgSerialConsoleNoAuth=0
cfgSerialConsoleCommand=
cfgSerialConsoleColumns=0
cfgSerialHistorySize=8192
cfgSerialTelnetEnable=0
cfgSerialSshEnable=1
cfgSerialTelnetEnable (Read or Write)
Table 170. Details of cfgSerialTelnetEnable
Description
Enables or disables the Telnet console interface.
Legal Values
1 (TRUE)
0 (FALSE)
Default
0
cfgOobSnmp
This group contains parameters to configure the SNMP agent and trap capabilities of iDRAC. One instance of the group is allowed.
The CMC SNMP agent supports the standard RFC1213 mib-2 and the Dell enterprise-specific the MIB.
This group is not applicable for iDRAC on Rack and Tower Servers.
The following sections provide information about the objects in the cfgOobSnmp group.
iDRAC Property Database Group and Object Descriptions
173