CLI Guide

License Required
iDRAC Express or iDRAC Enterprise
Dependency
None
System.Power.PCIeAllocation (Read or Write)
Table 454. Details of System.Power.PCIeAllocation
Description
Specifies PCIe power allocation for blade servers. It is applicable only for PowerEdge M610x.
NOTE: This object only applies to servers that support PCIe Card.
Legal Values
0 — Disabled
1 — Enabled
Default Value
0 — For platforms that do not support PCIe cards.
500 W — For platforms that support PCIe cards.
Write Privilege
Configure iDRAC
License Required
iDRAC Express or iDRAC Enterprise
Dependency
None
System.Power.PFCEnable (Read or Write)
Table 455. Details of System.Power.PFCEnable
Description
Enables the power factor correction enable.
NOTE:
This object is supported only for iDRAC on Rack and Tower servers.
This object is applicable only if System.Power.Cap.Enable is set to 1.
Legal Values
0 — Disabled
1 — Enabled
Default Value
0 — Disabled
Write Privilege
Configure iDRAC
License Required
iDRAC Express or iDRAC Enterprise
Dependency
None
System.Power.RedundancyCapabilities (Read Only)
Table 456. Details of System.Power.RedundancyCapabilities
Description
Returns the redundancy capabilities in the form of a bitmask. This bitmask indicates the values that are set to
cfgSensorRedundancyPolicy.
NOTE: This object is not applicable for iDRAC on Blade servers.
Legal Values
0 — not applicable
1 — Non-Redundant
Database Objects With Get and Set Commands 261