CLI Guide

2 — 1+1 Redundant
4 — 2+1 Redundant
8 — 2+2 Redundant
16 — 3+x Redundant
32 — 4+x Redundant
64 — 5+x Redundant
Default Value
0 — not applicable
Write Privilege Not Applicable
License Required Not Applicable
Dependency Not Applicable
System.Power.RedundantState (Read Only)
Table 457. Details of System.Power.RedundantState
Description
Retrieves the redundancy state for the chassis.
NOTE: This object is not applicable for Rack and Tower server.
Legal Values
0 — None
1 — Full
Default 0 — None
Write Privilege Not Applicable
License Required Not Applicable
Dependency Not Applicable
System.Power.Supply
This group provides information relating to the Power Supplies.
This group is indexed from 1 to 4. If there are less than four power supplies on the server, then some of the last indexes of this group are
not applicable. This group is applicable for iDRAC on Rack and Tower servers.
The following section provides information about the objects in this group.
System.Power.Supply.CurrentDraw (Read Only)
Table 458. Details of System.Power.Supply.CurrentDraw
Description
Displays the instantaneous current consumption in 0.1 amps.
Legal Values
String of up to 254 ASCII characters
Default Value Not Applicable
Write Privilege Not Applicable
License Required
iDRAC Express or iDRAC Enterprise
Dependency
None
262 Database Objects With Get and Set Commands