CLI Guide

idrac.alert.all
idrac.alert.audit
idrac.alert.audit.lic
idrac.alert.audit.warning
idrac.alert.audit.lic.critical
This command does not support setting the proxy parameters if the share location (-l) is HTTP/HTTPS. For more
information, see Proxy parameter section.
Input get—Displays the list of eventfilter settings
set—Configures the actions and notifications for a given eventfilter configuration
-i—Message ID for which the simulation is needed
-c—Alert category of the specific event filter
-a—The action that must be invoked when the event occurs. Valid values are none, powercycle, power
off, or systemreset
-n—The notification is sent when the event occurs. Valid values are all, snmp, ipmi, ws-events,
redfish-events, oslog, email, remotesyslog, or none. You can append multiple notifications that
are separated by a comma. You cannot enter the values all or none with other notifications. If incorrect
notification is specified along with other valid notifications, the valid and invalid notification set is failed.
-r—Event generation interval. This option is applicable only to the temperature statistics subcategory tmps.
You can use this option as a stand-alone or with -n and -a.
NOTE: If both event generation interval and notifications are configured and there is an error while
configuring the notifications, the event generation interval is not set. The valid values are 0–365. 0
disables the event generation.
Example Display all available event filter configurations.
racadm eventfilters get -c idrac.alert.all
Display eventfilter configurations for a specific category. For example, audit
racadm eventfilters get -c idrac.alert.audit
Display eventfilter configurations for a specific subcategory. For example, licensing under the audit category
racadm eventfilters get -c idrac.alert.audit.lic
Display eventfilter configurations for a specific severity. For example, warning under the audit category
racadm eventfilters get -c idrac.alert.audit.warning
Display eventfilter configurations for a specific severity and subcategory. For example, a severity of warning in
the subcategory licensing under audit category
racadm eventfilters get -c idrac.alert.audit.lic.warning
Clear all available alert settings.
racadm eventfilters set -c idrac.alert.all -a none -n none
Configure using severity as a parameter. For example, all informational events in storage category are assigned
power off as action, and email and SNMP as notifications.
racadm eventfilters set -c idrac.alert.storage.info -a poweroff -n
email,snmp
Configure using subcategory as a parameter. For example, all configurations under the licensing subcategory in
the audit category are assigned power off as action and all notifications are enabled.
racadm eventfilters set -c idrac.alert.audit.lic -a poweroff -n all
56
RACADM Subcommand Details